Preferred Language
Articles
/
-OZ4wpwBmraWrQ4dTk83
Behavior of Stiffened Stainless-Steel Tube Columns Filled with Steel Fiber Concrete
...Show More Authors

This research explored the performance of steel fiber concrete-filled stainless-steel tube columns stiffened with embedded carbon steel T-sections with various steel fiber ratios under biaxial bending conditions. A numerical parametric analysis was adopted, using finite element modeling with Abaqus CAE/2021 to evaluate the effects of the fiber ratio (ranging from 0% to 1.5%) on the load-bearing capacity and deflection behavior of columns. In addition, the compressive strength of concrete ranged between 45 and 65 MPa. An increase in the fiber ratio led to a substantial improvement in the ultimate load-bearing capacity (up to 24%), a reduction in deflection (of approximately 49%), and an improvement in column ductility, which were obtained at 1.25% fiber content. The addition of steel fibers enhanced column performance, and energy absorption improved by up to 27% compared to specimens without steel fibers. Experimental validation demonstrated improved accuracy in terms of behavior and predicted models. The conclusions of this work provide valuable design insights enabling the adaptation of the overall column system under complex loading scenarios.

Scopus Crossref
View Publication
Publication Date
Wed Mar 20 2019
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Heat Exchanger Performance by Using Dimpled Tube
...Show More Authors

The enhancement of heat exchanger performance was investigated using dimpled tubes tested at different Reynolds numbers, in the present work four types of dimpled tubes with a specified configuration manufactured, tested and then compared performance with the smooth tube and other passive techniques performance. Two dimpled arrangements along the tube were investigated, these are inline and staggered at constant pitch ratio X/d=4, the test results showed that Nusselts number (heat transfer) of the staggered array is higher than the inline array by 13%.  The effect of different depths of the dimple (14.5 mm and 18.5 mm) has been also investigated; a tube with large dimple diameter enhanced the Nusselts number by about 25% for the ran

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Factors Affecting the Operation of a Fire Tube Boiler
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Mar 30 2013
Journal Name
Mathematical Problems In Engineering
CFD analysis of Heat transfer and friction factor characteristics in a circular tube fitted with Quadrant-cut twisted tape inserts
...Show More Authors

Publication Date
Mon Mar 15 2021
Journal Name
Energies
Intensifying the Charging Response of a Phase-Change Material with Twisted Fin Arrays in a Shell-And-Tube Storage System
...Show More Authors

A twisted-fin array as an innovative structure for intensifying the charging response of a phase-change material (PCM) within a shell-and-tube storage system is introduced in this work. A three-dimensional model describing the thermal management with charging phase change process in PCM was developed and numerically analyzed by the enthalpy-porosity method using commercial CFD software. Efficacy of the proposed structure of fins for performing better heat communication between the active heating surface and the adjacent layers of PCM was verified via comparing with conventional longitudinal fins within the same design limitations of fin material and volume usage. Optimization of the fin geometric parameters including the pitch, numb

... Show More
View Publication Preview PDF
Scopus (58)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Sun Aug 07 2022
Journal Name
Engineering, Technology & Applied Science Research Etasr
Flexural Strengthening of Prestressed Girders with Partially Damaged Strands Using Enhancement of Carbon Fiber Laminates by End Sheet Anchorages
...Show More Authors

This paper examines the impact of flexural strengthening on the percentage of damaged strands in internally unbonded tendons in partially prestressed concrete beams (0, 14.28%, and 28.57%) and the recovering conditions using CFRP composite longitudinal laminates at the soffit, and end anchorage U-wrap sheets to restore the original flexural capacity and mitigate the delamination of the soffit of longitudinal Carbon Fiber Reinforced Polymer (CFRP) laminates. The composition of the laminates and anchors affected the stress of the CFRP, the failure mode, and thus the behavior of the beam. The experimental results revealed that the usage of CFRP laminates has a considerable impact on strand strain, particularly when anchors are employed

... Show More
Crossref (12)
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Optical Fiber Technology
Enhancing refractive index sensitivity using micro-tapered long-period fiber grating inscribed in biconical tapered fiber
...Show More Authors

View Publication
Scopus (20)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Mon Jun 24 2019
Journal Name
University Of Thi-qar Journal
Assessment of the Performance of Stone Columns through the Seismic Wave Test: A Review
...Show More Authors

The geophysical testing is increasingly being employed in many geotechnical applications. It is preferred in monitoring the mechanical characteristics of the ground because of its economy, not time consuming and non-destructive nature. Seismic wave test is one of the geophysical methods which showed a potential in observing the general behaviour of the reinforced soil with stone columns. Findings in most cases showed that the seismic wave measurements was integrated with or compared to the conventional tests such as standard penetration test or cone penetration test. There was a noticeable success in identifying the enhancement achieved to the ground upon the strengthening with the column, specifically when the associated surveys can produc

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 02 2025
Journal Name
Engineering, Technology & Applied Science Research
Analytical and Theoretical Development of Load-Moment Interaction Diagrams of Rectangular CFRP-RC Columns
...Show More Authors

Carbon Fiber-Reinforced Polymer (CFRP) bars have several advantages over traditional steel reinforcement, including low density, erosion resistance, and higher tensile strength. The ACI 440.11-22 code permits CFRP as reinforcement; however, there are limited experimental studies on its application in Reinforced Concrete (RC) columns under combined loads. This study utilized theoretical analysis and Finite Element Analysis (FEA) to investigate 25 square slender concrete columns (kL/r = 17) affected by concentric and eccentric loads, examining variables, like CFRP bar contribution, eccentricity-to-depth ratio, and reinforcement arrangement. The results demonstrated CFRP's effectiveness in these columns, with failure modes varying from

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Nov 28 2018
Journal Name
International Journal Of Engineering & Technology
Using Polyurethane Coating of Concrete Pipes with Acid Attack Resistance in Sewer Lines
...Show More Authors

One of the most important challenges facing the designers of the sewerage system is the corrosion of sewers due to the influence of sewerage contaminates which lead to failure of the main lines of sewers. In this study, a reference mix of 1: 1.5: 3 was used and the 4% Flocrete PC200 by weight of cement was added to the same mixing ratio in the second mixture. Twenty-four samples were tested for each mixture, 12 of which were used to compression strength test in ages (7, 14 and 28) day and six samples were submerged after 28 days of wet treatment at (5 and 10) % concentrations of sulfuric acid. The other six samples were painted after 28 days of wet treatment with coating Polyurethane and after 24 hours were flooded with a concentrat

... Show More
View Publication
Crossref
Publication Date
Sun Jan 23 2022
Journal Name
Buildings
Structural Efficiency of Non-Prismatic Hollow Reinforced Concrete Beams Retrofitted with CFRP Sheets
...Show More Authors

Non-prismatic reinforced concrete (RC) beams are widely used for various practical purposes, including enhancing architectural aesthetics and increasing the overall thickness in the support area above the column, which gives high assurance to services that this will not result in the distortion of construction features and can reduce heights. The hollow sections (recess) can also be used for the maintenance of large structural sections and the safe passage of utility lines of water, gas, telecommunications, electricity, etc. They are generally used in large and complex civil engineering works like bridges. This study conducted a numerical study using the commercial finite element software ANSYS version 15 for analysing RC beams, hol

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref