Preferred Language
Articles
/
-BfQ8I0BVTCNdQwCuilh
In vitro apical microleakage evaluation for different endodontic sealers by spectrophotometric analysis: an observational study
...Show More Authors

Background: It has been established that several filling techniques can affect apical leakage, which is responsible for 59% of endodontic failures. The primary goal of endodontic therapy is to create a tight seal that aids in repairing the periapical tissues, prevents apical periodontitis, and shields against root canal infection. The study aims to compare the apical sealing ability of epoxy resin based sealer  (AH plus), which is an epoxy-resin-based root canal sealer, GuttaFlow 2, which is a silicone-based root canal sealer, GuttaFlow bioseal is a bioactive glass-based root canal sealer, TotalFill HiFlow bioceramic (BC) sealer is a silicate-based root canal sealer (bioceramic sealer) using a single cone technique by spectrophotometric analysis.

 Methods: This study chose 64 maxillary first molars with a straight palatal root. Following palatal roots sectioning to 11 mm from the root apex, the canals were instrumented up to size X4 using Protaper Next. They were separated into  four experimental groups (n = 15) per each group based on the kind of sealer utilized, Group I: AH plus, Group II: GuttaFlow 2, Group III: GuttaFlow bioseal, Group IV: TotalFill BC HiFlow, and two control groups (n =2 for each).  After completing obturation, the dye extraction technique was used to evaluate apical leakage. A spectrophotometer was used to measure the optical density of the solution after all the dyes were liberated from the interfacial regions.

Result: A statistically non-significant difference between the investigated root canal sealers in apical microleakage P > 0.05 was noted. The highest mean values were observed in group IV (0.08046), group I(0.07731), and group II(0.06209), while the lowest mean value in group III (0.05719)

Conclusions: All types of sealers used in this investigation showed various amounts of microleakage. None of the sealants could completely close the apical foramen to provide a fluid-tight seal.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Cephalometric evaluation of a sample of Iraqi adults with normal occlusion using tetragon analysis
...Show More Authors

Background: This study aimed to determine the cephalometric values of tetragon analysis on a sample of Iraqi adults with normal occlusion. Material and methods: Forty digital true lateral cephalometric radiographs belong to 20 males and 20 females having normal dental relation were analyzed using AutoCAD program 2009. Descriptive statistics and sample comparison with Fastlicht norms were obtained. Results: The results showed that maxillary and mandibular incisors were more proclined and the maxillary/mandibular planes angle was lower in Iraqi sample than Caucasian sample. Conclusion: It's recommended to use result from this study when using tetragon analysis for Iraqis to get more accurate result.

View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of The College Of Languages (jcl)
An excerpt on the analysis of correlate constructions: Exkurs zur Analyse der Korrelatkonstruktionen
...Show More Authors

The main idea that led me to write such research paper within the framework of Germanic linguistics is that I have not found any topic dealing with the term correlate in the German language, except in several articles in linguistic journals as well as one topic in a book describing the use of such a linguistic phenomenon in the language system. The research initially deals with the definition of the correlate at the level of the German language system. Correlate is unity describes specific relation of two sentences and identifies denoted constructs. Correlate is called a placeholder at the syntactic level because it does not occupy its original topological fields in the syntactic structure. The correlate (es) or the prepositiona

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 02 2022
Journal Name
Engineering, Technology & Applied Science Research
Reliability Analysis of an Uncertain Single Degree of Freedom System Under Random Excitation
...Show More Authors

In practical engineering problems, uncertainty exists not only in external excitations but also in structural parameters. This study investigates the influence of structural geometry, elastic modulus, mass density, and section dimension uncertainty on the stochastic earthquake response of portal frames subjected to random ground motions. The North-South component of the El Centro earthquake in 1940 in California is selected as the ground excitation. Using the power spectral density function, the two-dimensional finite element model of the portal frame’s base motion is modified to account for random ground motions. A probabilistic study of the portal frame structure using stochastic finite elements utilizing Monte Carlo simulation

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Oct 16 2023
Journal Name
Nano And Medical Materials
Preparation and analysis of silver Nanoparticles (Ag Nps) by plant extract techniques of green tea and study optical and structural properties
...Show More Authors

Aqueous root extract has been used to examine the green production of silver nanoparticles (AgNPs) by reducing the Ag+ ions in a silver nitrate solution. UV-Vis spectroscopy, X-ray diffraction, field emission scanning electron microscopy, and Fourier transform infrared spectroscopy (FTIR) were used to analyze the produced AgNPs. The AgNPs that were created had a maximum absorbance at 416 nm, were spherical in form, polydispersed in nature, and were 685 nm in size.The AgNPs demonstrated antibacterial efficacy against Escherichia coli and Staphylococcus. The dengue vector Aedes aegypti's second instar larvae were very susceptible to the AgNPs' powerful larvicidal action.

View Publication
Crossref (5)
Crossref
Publication Date
Thu Jun 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength of zirconia to tooth structure after different zirconia surface treatment techniques
...Show More Authors

Background: This study aimed to evaluate the effect of zirconia different surface treatments (primer, sandblast with 50μmAl2O3, Er,Cr:YSGG laser) on shear bond strength between zirconia surface and resin cement. Material and methods: Sixty presintered Y-TZP zirconia cylinder specimens (IPS e.max ZirCAD, Ivoclar vivadent) will be fabricated and sintered in high temperature furnace of (1500 C for 8 hours) according to manufacturer’s instructions to the selected size and shape of (5mm. in diameter and 6mm in height). All specimens were ground flat using 600.800.1000.1200, aluminum oxide abrasive paper to obtain a standardized surface roughness. Surface roughness values were then recorded in µm using surface roughness tester (profi

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
An investigation into the performance of counter rotating floating ring journal under different working conditions
...Show More Authors

The steady state performance of the counter rotating floating ring Journal bearing is analyzed with isothermal finite bearing theory. The effect of different parameters affecting the performance of the bearing (namely speed ratio, clearance ratio and radii ratio), have been investigated. The load carrying capacity of the bearing increasing with decreasing the radii ratio (R2/R1) of the ring and clearance ratio (c1/c2), in the other hand, the coefficient of friction increases with increasing the clearance and radii ratios, while decreases with incre4asing the bearing to journal speed ratio (γ). It is shown during this work that different operating conditions are greatly enhanced the performance

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Derivative of an image that corrupted by additive noise
...Show More Authors

In this paper the behavior of the quality of the gradient that implemented on an image as a function of noise error is presented. The cross correlation coefficient (ccc) between the derivative of the original image before and after introducing noise error shows dramatic decline compared with the corresponding images before taking derivatives. Mathematical equations have been constructed to control the relation between (ccc) and the noise parameter.

View Publication Preview PDF
Crossref
Publication Date
Thu Mar 10 2022
Journal Name
Oral Surgery
Evaluation of buffered local anaesthesia in dental extraction: A randomized controlled study
...Show More Authors

Buffering of Local anaesthesia (LA) has been suggested as a mechanism to improve injection comfort and hasten the onset of anaesthesia. Aim This study aimed to evaluate the effectiveness of buffered LA in the extraction of maxillary premolars and molars. Materials and Methods This randomized controlled study included 100 patients who were indicated for extraction of maxillary posterior teeth, they were randomly divided into two groups; a study group that received infiltration of buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA, and a control group that received non-buffered 2% lidocaine hydrochloride with 1:80,000 epinephrine LA. The buffering was performed using the Onset® LA buffering system (Onpharma®). The outcome va

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Thu Nov 13 2014
Journal Name
Asian Academic Research Associates
Thermodynamic Study of Poly (Vinyl Alcohol) in Aqueous Solution and in Tetrahydrofurfuryl alcohol at Different Temperatures
...Show More Authors