Preferred Language
Articles
/
-BfQ8I0BVTCNdQwCuilh
In vitro apical microleakage evaluation for different endodontic sealers by spectrophotometric analysis: an observational study
...Show More Authors

Background: It has been established that several filling techniques can affect apical leakage, which is responsible for 59% of endodontic failures. The primary goal of endodontic therapy is to create a tight seal that aids in repairing the periapical tissues, prevents apical periodontitis, and shields against root canal infection. The study aims to compare the apical sealing ability of epoxy resin based sealer  (AH plus), which is an epoxy-resin-based root canal sealer, GuttaFlow 2, which is a silicone-based root canal sealer, GuttaFlow bioseal is a bioactive glass-based root canal sealer, TotalFill HiFlow bioceramic (BC) sealer is a silicate-based root canal sealer (bioceramic sealer) using a single cone technique by spectrophotometric analysis.

 Methods: This study chose 64 maxillary first molars with a straight palatal root. Following palatal roots sectioning to 11 mm from the root apex, the canals were instrumented up to size X4 using Protaper Next. They were separated into  four experimental groups (n = 15) per each group based on the kind of sealer utilized, Group I: AH plus, Group II: GuttaFlow 2, Group III: GuttaFlow bioseal, Group IV: TotalFill BC HiFlow, and two control groups (n =2 for each).  After completing obturation, the dye extraction technique was used to evaluate apical leakage. A spectrophotometer was used to measure the optical density of the solution after all the dyes were liberated from the interfacial regions.

Result: A statistically non-significant difference between the investigated root canal sealers in apical microleakage P > 0.05 was noted. The highest mean values were observed in group IV (0.08046), group I(0.07731), and group II(0.06209), while the lowest mean value in group III (0.05719)

Conclusions: All types of sealers used in this investigation showed various amounts of microleakage. None of the sealants could completely close the apical foramen to provide a fluid-tight seal.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 29 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Olive Oil as a Separating Medium and Its Effect on Some Mechanical Properties of Processed Acrylic Resin Denture Base (A Comparative Study). Part Two
...Show More Authors

Background: During acrylic resin processing, the mold must be separated from the surface of the gypsum to prevent liquid resin from penetrating into the gypsum, and water from the gypsum seeping into the acrylic resin. For many years, tin foil was the most acceptable separating medium, and because it's difficult to apply, a tin-foil substitute is used. In this study, olive oil is used as an alternative to tin foil separating medium for first time, and evaluating its effect as a separating medium on some mechanical properties such as (indentation hardness and transverse strength) of acrylic resins denture base comparing it with those processed using tin-foil and tin foil substitute such as (cold mold seal) separating medium. Materials and M

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 20 2021
Journal Name
College Of Islamic Sciences
Positive images in the Holy Quran The story of Solomon - peace be upon him - in Surat An-Naml is a model An objective study
...Show More Authors

God Almighty put in his great book secrets that do not end, and wonders that do not expire, for he is the one from which the scholars are not satisfied, and he does not create due to the multitude of response, and it is the comprehensive and inhibitory book that God conceals to the worlds, and he challenged the two heavyweights to come up with something like it.

At all times, issues arise in the Noble Qur’an that fit the needs of the people of that time and their culture, for it is an eternal book, characterized by the ability to give, extend and respond to addressing the problems of the age and its variables, when the Arabs had little luck at the time of the message’s descent from the scientific culture, and their proficienc

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Nitrofurantoin Drug in its Pharmaceutical Formulations Using MBTH as a Coupling Reagent
...Show More Authors

A direct, sensitive and efficient spectrophotometric method for the determination of nitrofurantoin
drug (NIT) in pure as well as in dosage form (capsules) was described. The suggested method was
based on reduction NIT drug using Zn/HCl and then coupling with 3-methyl-2-benzothiazolinone
hydrazone hydrochloride (MBTH) in the presence of ammonium ceric sulfate. Spectrophotometric
measurement was established by recording the absorbance of the green colored product at 610 nm.
Using the optimized reaction conditions, beer’s law was obeyed in the range of 0.5-30 μg/mL, with
good correlation coefficient of 0.9998 and limits of detection and quantitation of 0.163 and 0.544
μg/mL, respectively. The accuracy and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
The Journal Of Immunology
Definition of the Nature and Hapten Threshold of the β-Lactam Antigen Required for T Cell Activation In Vitro and in Patients
...Show More Authors
Abstract<p>Covalent modification of protein by drugs may disrupt self-tolerance, leading to lymphocyte activation. Until now, determination of the threshold required for this process has not been possible. Therefore, we performed quantitative mass spectrometric analyses to define the epitopes formed in tolerant and hypersensitive patients taking the β-lactam antibiotic piperacillin and the threshold required for T cell activation. A hydrolyzed piperacillin hapten was detected on four lysine residues of human serum albumin (HSA) isolated from tolerant patients. The level of modified Lys541 ranged from 2.6 to 4.8%. Analysis of plasma from hypersensitive patients revealed the same pattern and leve</p> ... Show More
View Publication
Scopus (59)
Crossref (59)
Scopus Clarivate Crossref
Publication Date
Sat May 04 2024
Journal Name
Chemchemtech
HPLC METHOD FOR THE DETERMINATION OF SOME ANTIBIOTIC RESIDUES IN DIFFERENT HOSPITALS WASTEWATER IN BAGHDAD CITY, IRAQ
...Show More Authors

Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, Al-Kindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat May 04 2024
Journal Name
Chemchemtech
HPLC METHOD FOR THE DETERMINATION OF SOME ANTIBIOTIC RESIDUES IN DIFFERENT HOSPITALS WASTEWATER IN BAGHDAD CITY, IRAQ
...Show More Authors

Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, AlKindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18 co

... Show More
Scopus (4)
Scopus
Publication Date
Wed Dec 01 2021
Journal Name
Computers &amp; Electrical Engineering
Utilizing different types of deep learning models for classification of series arc in photovoltaics systems
...Show More Authors

View Publication
Crossref (10)
Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Modified Simplex - Spectrophotometric Determination of Clonazepam via Charge-Transfer Complexation
...Show More Authors

A simple, sensitive, accurate, and precise spectrophotometric method for the determination of clonazepam (CLNZ) was developed. The method is based on charge transfer reaction between CLNZ and p-Bromanil (p-Br) to form a colored complex. The optimum conditions of complex formation were investigated by (1). Unvariable method, for the optimization of reagent concentration, base concentration, temperature, and time. (2). Multivariable simplex method including the effect of three experimental factors via; reagent concentration, concentration of NaOH and time. The linearity range of CLNZ was (1-30) μg.mL-1 at 378 nm under condition established via simplex method with molar absorptivity (1.9069x104) L.

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Different methods for characterizing surface roughness using laser speckle technique
...Show More Authors

In this work, results from an optical technique (laser speckle technique) for measuring surface roughness was done by using statistical properties of speckle pattern from the point of view of computer image texture analysis. Four calibration relationships were used to cover wide range of measurement with the same laser speckle technique. The first one is based on intensity contrast of the speckle, the second is based on analysis of speckle binary image,  the third is on size of speckle pattern spot, and the latest one is based on characterization of the energy feature of the gray level co-occurrence matrices for the speckle pattern. By these calibration relationships surface roughness of an object surface can be evaluated within the

... Show More
View Publication Preview PDF
Crossref