Preferred Language
Articles
/
-Bex5I8BVTCNdQwCzn_x
Diagnostic Evaluation of Uterine Artery Doppler Imaging for the Prediction of Early Abnormal Pregnancy
...Show More Authors

Objective: to assess the predictive value of Doppler imaging of the uterine artery in the identification of early intrauterine abnormal pregnancy as compared to a normal intrauterine pregnancy. Subjects and methods: one hundred and twenty pregnant ladies, at their 6-12 weeks of gestation, with a singleton pregnancy were included in this population-based case-control study. Thirty women with a missed miscarriage, 30 with hydatidiform mole, 30 with a blighted ovum, and 30 as a control group, without risk factors, underwent Doppler interrogation of the uterine arteries. Resistive index (RI), pulsatility index (PI), and the systolic/diastolic ratio (S/D) were measured for both sides. The t-test, or ANOVA test when appropriate, was used to analyze the relationship between the variables. Results: there was a significant reduction of RI mean, PI mean, and S/D ratio among women with different types of abnormal pregnancy compared with the control group. RI and PI mean levels were significantly lower in women with hydatidiform mole and significantly higher in women with missed miscarriage. Lower left S/D mean level was significantly associated with hydatidiform mole and upper left S/D level was associated significantly with control women. For prediction of missed miscarriage; right and left uterine artery RI shows a sensitivity of 80%, 73.3%, a specificity of 68%, 71.1%, and the highest AUC was 0.78 for both.For prediction of molar pregnancy, right and left uterine artery RI showed a sensitivity of 63% for both, a specificity of 54.4%, 60%, and the highest AUC was 0.58, 0.61 respectively. Conclusions: Uterine artery Doppler ultrasonography at 6-12 weeks of gestation is predictive for early pregnancy complications such as missed abortion, hydatidiform mole, and blighted ovum.

Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Geological Journal
Depositional Environment of the Ibrahim Formation and Determining the Oligocene-Early Miocene Boundary in Eastern Iraq
...Show More Authors

The aim of this study is to investigate the sedimentation environments and diagenetic processes of the Ibrahim Formation (Oligocene-early Miocene) in Zurbatiya, eastern Iraq. The Ibrahim Formation is comprised mostly of clayey micrite and skeletal grains composed of planktonic foraminifera, calcispheres, radiolaria, and benthic foraminifera. Glauconite and pyrite were documented in some restricted zones of this formation; they reflect quiet and reducing conditions. Radiolaria were identified in Late-Oligocene which was not known previously at this age regionally in carbonate formations of the Arabian Plate (AP). Mudstone, wackestone, and planktonic foraminiferal wackepackstone are the main microfacies that are affected by dissolutio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
Discrimination of Malignant from Acute Benign Compression Spinal Fractures with Magnetic Resonance imaging
...Show More Authors

Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Science
Subsurface Imaging of 2D Seismic Data Using Kirchhoff Time Migration Method, Central Iraq
...Show More Authors

Kirchhoff Time Migration method was applied in pre-and post-Stack Time Migration for post-processing of images collected from Balad-Samarra (BS-92) survey line that is sited across Ajeel anticline oilfield. The results showed that Ajeel anticline structure was relocated at the correct position in the migrated stacked section. The two methods (Pre and Post) of migration processing showed enhanced subsurface images and increased horizontal resolution, which was clear after the broadening the syncline and narrowing or compressing the anticline. However, each of these methods was associated with migration noise. Thus, a Post-Stack process was applied using Dip-Removal (DDMED) and Band-Pass filters to eliminate the artifact noise. The time-fr

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Clinical And Angiographic Characteristics Of Left Main Coronary Artery Disease, A Retrospective Study
...Show More Authors

Background : Left main coronary artery (LMCA) disease represents important and serious portion of coronary artery disease(CAD).
Aim: The aim of this study is to estimate the incidence of LMCA disease among patients with CAD undergoing coronary artery angiography and to evaluate clinical characteristics of patients with LMCA disease.
Methods: The study involved review of clinical notes and coronary angiography of 1020 patients with CAD in Ibin Al Bitar hospital for cardiac surgery between April and September 2004.This review included evaluation of electrocardiogram (ECG), echocardiogram(ECHO), ECG exercise test (EET) and coronary angiography.
Results: Among 56 patients proved to have left main corona

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Evaluation of the one electron expeetation values for different wave functions
...Show More Authors

The aim of this work is to evaluate the onc-electron expectation values < r > from the radial electronic density funetion D(r) for different wave ?'unctions for the 2s state of Li atom. The wave functions used were published in 1963,174? and 1993 , respectavily. Using " " ' wave function as a Slater determinant has used the positioning technique for the analysis open shell system of Li (Is2 2s) State.

View Publication Preview PDF
Publication Date
Thu May 04 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Linear Prediction of Sum of Two Poisson Process
...Show More Authors

Our goal from this work is to find the linear prediction of the sum of two Poisson process
) ( ) ( ) ( t Y t X t Z + = at the future time 0 ), ( ≥ + τ τ t Z and that is when we know the values of
) (t Z in the past time and the correlation function ) (τ βz

View Publication Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Artificial Neural Network (ANN) for Prediction of Viscosity Reduction of Heavy Crude Oil using Different Organic Solvents
...Show More Authors

The increase globally fossil fuel consumption as it represents the main source of energy around the world, and the sources of heavy oil more than light, different techniques were used to reduce the viscosity and increase mobility of heavy crude oil. this study focusing on the experimental tests  and modeling with Back Feed Forward Artificial Neural Network (BFF-ANN) of the dilution technique to reduce a  heavy oil viscosity that was collected from the south- Iraq oil fields using organic solvents, organic diluents with different weight percentage  (5, 10 and  20 wt.% )  of  (n-heptane, toluene, and a mixture of  different ratio

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 15 2022
Journal Name
Romanian Neurosurgery
Mobilization of the temporal pole as integrated step in microsurgical clipping of pure posteriorly directed posterior communicating artery aneurysm
...Show More Authors

A pure posteriorly posterior communicating artery (PCoA) aneurysm represents a surgical challenge. This is mainly when there is a need for good exposure of the aneurysmal neck, sac, PCoA, and anterior choroidal arteries. Ruptured pure posteriorly directed PCoA aneurysm imposes significantly extra challenge as the surgeon undergoes dissection through a tight brain. Even with measures commonly used to attain brain relaxation like the lumbar drain and cisternal fenestration. Here, we describe a technique for posterior temporal pole mobilization (TPM) as an integrated part of microsurgical clipping of ruptured pure posteriorly directed PCoA aneurysms. This technique is implicated in twenty-three successive cases of ruptured PCoA aneurys

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jul 21 2022
Journal Name
Neuro Quantology
Astronomical Observation between Diffraction Limited Coherent and Incoherent Imaging Systems
...Show More Authors

Numerical simulations are carried out to evaluate the coherence concept’s effect on the performance regarding the optical system, when observing and imaging the planet’s surface. In numerous optical approaches, the coherence qualities of light sources play an important role. This paper provides an overview about the mathematical formulation of temporal and spatial coherence and incoherence properties of light sources. The circular aperture was used to describe the optical system like a telescope. The simulation results show that diffraction-limited for incoherent imaging system certainly improves the image. Yet, the quality of the image is degraded by the light source's highly spatial and temporal coherence properties, resulting in a

... Show More
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More