Preferred Language
Articles
/
-Bb3R4cBVTCNdQwCGEAv
Clinical and Radiographical Assessment of Alveolar Bone Loss Associated with Overhang Amalgam Filling
...Show More Authors

Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Intelligent Systems
An online COVID-19 self-assessment framework supported by IoMT technology
...Show More Authors
Abstract<p>As COVID-19 pandemic continued to propagate, millions of lives are currently at risk especially elderly, people with chronic conditions and pregnant women. Iraq is one of the countries affected by the COVID-19 pandemic. Currently, in Iraq, there is a need for a self-assessment tool to be available in hand for people with COVID-19 concerns. Such a tool would guide people, after an automated assessment, to the right decision such as seeking medical advice, self-isolate, or testing for COVID-19. This study proposes an online COVID-19 self-assessment tool supported by the internet of medical things (IoMT) technology as a means to fight this pandemic and mitigate the burden on our nation</p> ... Show More
View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Sep 20 2023
Journal Name
Journal Of Applied And Natural Science
Detection of some virulence genes (esp, agg, gelE, CylA) in Enterococcus faecalis isolated from different clinical cases at Baghdad
...Show More Authors

The virulent genes are the key players in the ability of the bacterium to cause disease. The products of such genes that facilitate the successful colonization and survival of the bacterium in or cause damage to the host are pathogenicity determinants. This study aimed to investigate the prevalence of virulence factors (esp, agg, gelE, CylA) in E. faecalis isolated from diverse human clinical collected in Iraqi patient , as well as to assess their ability to form biofilm and to determine their haemolytic and gelatinase activities. Thirty-two isolates of bacteria Enterococcus faecalis were obtained, including 15 isolates (46.87%) of the urine, 6 isolates (18.75%) for each of the stool and uterine secretions, and 5 isolates (15.62%) of the wo

... Show More
Preview PDF
Publication Date
Wed Nov 23 2022
Journal Name
Dental Hypotheses
Remineralization of Dentine Caries Using Moringa Oleifera Based Nano-Silver Fluoride: A Single-Blinded, Randomized, Active-Controlled Clinical Trial
...Show More Authors

View Publication
Scopus (12)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
A Developed Colorimetric Assay Using Unmodified Gold Nanoparticles for the Identification of Acinetobacter baumannii Isolates from Different Clinical Samples
...Show More Authors

  Acinetobacter baumannii (A. baumannii ) is considered a critical healthcare problem for patients in intensive care units due to its high ability to be multidrug-resistant to most commercially available antibiotics. The aim of this study is to develop a colorimetric assay to quantitatively detect the target DNA of A. baumannii based on unmodified gold nanoparticles (AuNPs) from different clinical samples (burns, surgical wounds, sputum, blood and urine). A total of thirty-six A. baumannii clinical isolates were collected from five Iraqi hospitals in Erbil and Mosul provinces within the period from September 2020 to January 2021. Bacterial isolation and biochemical identification of isolates

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Sat Jun 30 2012
Journal Name
The Iraqi Journal Of Veterinary Medicine
Conformation of the clinical diagnoses of some malnutrition diseases in local and Shammi goats in Baghdad province: Al-Shawi A.F.S .; Al-Sammarraie ,S.A.G.and Al-Judi Abdul,M.H.
...Show More Authors

The relationship between the clinical singes and some of the hematological and biochemical values in 126 cases of local breed and Shammi breed goats (from both sexes) diagnosed as cases of malnutrition from 230 goats examined .The clinical examination include (beside the general inspection and case history) body temperature, respiratory and pulse rates, mucus membranes skin and coat. Examination of the blood samples included RBCs count, Hb concentration, PCV % and values of cupper, magnesium, phosphorus, and potassium. The results showed that the mean body temperature of these goats was lower than in normal goats, while the respiratory and pulse rates were higher .Examination of blood revealed decrease in the means of RBCs counts ,Hb con

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 13 2023
Journal Name
International Conference Of Computational Methods In Sciences And Engineering Iccmse 2021
Management of the flood disaster and assessment their damaged areas using remote sensing and GIS techniques: A case study of Tigris River – Maysan Governorate, Iraq
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jul 03 2013
Journal Name
Eur. Chem. Bull
PREPARATION AND CHARACTERIZATION OF UNSATURATED POLYESTER MATERIAL BLENDED WITH CELLULOSE AND WITH ETHYL CELLULOSE.
...Show More Authors

Modified unsaturated polyester (MUPE) was blended with Cellulose (Cls) and with ethyl cellulose (ECls) at ambient conditions in the presence of ethyl methyl ketone peroxide (EMKP) as hardener. The blends containing different weight percentages (5-25 %) of Cls or ECls. Mechanical properties (impact strength, hardness, and bending) and dielectric constant were determined. The results observed that Cls increases the impact strength, hardness, and dielectric constant and decreases the bending of the MUPS, while ECls causes an increase in the three mechanical behaviours and a decrease in the dielectric constant of the MU-PS.

Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Crossref