Preferred Language
Articles
/
-BZ0CYsBVTCNdQwCmcb8
Fenton-like degradation of direct blue dye using green synthesised Fe/Cu bimetallic nanoparticles
...Show More Authors

This study relates to synthesis of bentonite-supported iron/copper nanoparticles through the biosynthesis method using eucalyptus plant leaf extract, which were then named E-Fe/Cu@B-NPs. The synthesised E-Fe/Cu@B-NPs were examined by a set of experiments involving a heterogeneous Fenton-like process that removed direct blue 15 (DB15) dye from wastewater. The resultant E-Fe/Cu@B-NPs were characterised by scanning electron microscopy, Brunauer–Emmet–Teller analysis, zeta potential analysis, Fourier transform infrared spectroscopy and atomic force microscopy. The operating parameters in batch experiments were optimised using Box–Behnken design. These parameters were pH, hydrogen peroxide (H2O2) dosage, E-Fe/Cu@B-NP dosage, initial DB15 concentration and temperature. The results showed that 94.32% of 57.5 mg/l DB15 was degraded within 60 min with an optimum hydrogen peroxide dosage of 7.5 mmol/l, an E-Fe/Cu@B-NP dosage of 0.55 g/l, a pH of 3.5 and a temperature of 50°C. The kinetic study indicated that the DB15 degradation kinetics fit the second-order kinetic model, and the thermodynamic factors proved that the process is non-spontaneous, endothermic and endergonic with an activation energy E a of 62.961 kJ/mol.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Compression of an ECG Signal Using Mixed Transforms
...Show More Authors

Electrocardiogram (ECG) is an important physiological signal for cardiac disease diagnosis. With the increasing use of modern electrocardiogram monitoring devices that generate vast amount of data requiring huge storage capacity. In order to decrease storage costs or make ECG signals suitable and ready for transmission through common communication channels, the ECG data
volume must be reduced. So an effective data compression method is required. This paper presents an efficient technique for the compression of ECG signals. In this technique, different transforms have been used to compress the ECG signals. At first, a 1-D ECG data was segmented and aligned to a 2-D data array, then 2-D mixed transform was implemented to compress the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Heliyon
Synthesis and Characterization of Some Metal Ions Complexes with Mixed Ligand of Azo Dye and Metformin and Evaluation of its Effectiveness on the Growth of Some Pathogenic Bacteria Clinically Isolated and Study of its Toxicity on Normal and Cancerous Hepatocytes
...Show More Authors

View Publication
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Heliyon
Synthesis and characterization of some Metal ions complexes with mixed ligand of azo dye and Metformin and evaluation of its effectiveness on the growth of some pathogenic bacteria clinically isolated and study of its Toxicity on normal and cancerous Hepatocytes
...Show More Authors

Four metal compounds mixed ligand of azo dye ligand (L) and metformin.(Met) were produced at aquatic ethanol for (1:1:1) (M:L:Met). The prepared compounds were identified by utilizing atomic absorption flame, FT.IR and UV–Vis spectrum manners as well as conductivity mensuration. These compounds was assayed of the gained datum the octahedral geometry was proposed into whole prepared complexes.Also in this research was studied represented examining the antibacterial and antifungal impact of the azo dye ligand (L), metformin.(Met) and (Co,Ni, Cu and Cd complexes) on four types of pathogenic, clinically isolated bacteria that are resistant to antibiotic, like Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneu

... Show More
Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Heliyon
Synthesis and characterization of some Metal ions complexes with mixed ligand of azo dye and Metformin and evaluation of its effectiveness on the growth of some pathogenic bacteria clinically isolated and study of its Toxicity on normal and cancerous Hepatocytes
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (16)
Scopus Crossref
Publication Date
Sat Sep 02 2023
Journal Name
Second International Conference On Innovations In Software Architecture And Computational Systems (isacs 2022)
Synthesis and characterization of SAPO-11 using carbon nanotubes
...Show More Authors

The thermal method was used to produce silicoaluminophosphate (SAPO-11) with different amounts of carbon nanotubes (CNT). XRD, nitrogen adsorption-desorption, SEM, AFM, and FTIR were used to characterize the prepared catalyst. It was discovered that adding CNT increased the crystallinity of the synthesize SAPO-11 at all the temperatures which studied, wile the maximum surface area was 179.54 m2/g obtained at 190°C with 7.5 percent of CNT with a pore volume of 0.317 cm3/g ,and with nano-particles with average particle diameter of 24.8 nm, while the final molar composition of the prepared SAPO-11 was (Al2O3:0.93P2O5:0.414SiO2).

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Science And Research (ij
Simulation of Chlorine Decay in Al-Gukook WaterDistribution Networks Using EPANET
...Show More Authors

The approach of the research is to simulate residual chlorine decay through potable water distribution networks of Gukookcity. EPANET software was used for estimating and predicting chlorine concentration at different water network points . Data requiredas program inputs (pipe properties) were taken from the Baghdad Municipality, factors that affect residual chlorine concentrationincluding (pH ,Temperature, pressure ,flow rate) were measured .Twenty five samples were tested from November 2016 to July 2017.The residual chlorine values varied between ( 0.2-2mg/L) , and pH values varied between (7.6 -8.2) and the pressure was very weak inthis region. Statistical analyses were used to evaluated errors. The calculated concentrations by the calib

... Show More
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Enhanced Oil Recovery using Smart Water Injection
...Show More Authors

Smart water flooding (low salinity water flooding) was mainly invested in a sandstone reservoir. The main reasons for using low salinity water flooding are; to improve oil recovery and to give a support for the reservoir pressure.

In this study, two core plugs of sandstone were used with different permeability from south of Iraq to explain the effect of water injection with different ions concentration on the oil recovery. Water types that have been used are formation water, seawater, modified low salinity water, and deionized water.

The effects of water salinity, the flow rate of water injected, and the permeability of core plugs have been studied in order to summarize the best conditions of low salinity

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction (pp.52-61)
Simulation of Residual Chlorine in Al-Yarmouk Drinking Water System Using WaterGEMS
...Show More Authors

Abstract To ensure that the distribution system has safe drinking water. It is necessary to know the residual chlorine concentrations at various points in the network. A chlorine photometer device was used to measure twenty points taken every day for a week at a selected time in the distribution system. Both pressures and flows in the network were measured using bourdon gauge and Tuf-2000H Handheld Digital ultrasonic flow meters. WaterGEMS CONNECT Edition update one software was used to simulate the flow in the network. The Baghdad water department provided the data about the network, such as the lengths of pipes, the layout of the network, and pipes diameters. The network calibrated consists of 781 pipes of different lengths and 542 juncti

... Show More
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Stabilization of Al-Rustamiya Waste Water Treatment Plant Sludge Using Lime
...Show More Authors

A study was performed to evaluate heavy metals removal from sewage sludge using lime. The processes of stabilization using alkaline chemicals operating on a simple principle of raising pH to 12 or higher, with sufficient mixing and suitable contact time to ensure that immobilization can reduce heavy metals. A 0.157 m3 tank was designed to treat Al-Rustemeyia wastewater treatment plant sludge. Characteristics of raw sludge were examined through two parameters: pH and heavy metal analysis. Different lime doses of (0- 25) g CaO/100 g sludge were mixed manually with raw sludge in a rotating drum. The samples were analyzed two hours after mixing. pH and heavy metals results were compared with EPA and National Iraqi Stand

... Show More
View Publication Preview PDF
Crossref (1)
Crossref