Preferred Language
Articles
/
-3j3QqEBuRolNscLzPkn
Damage of concrete columns reinforced with grouting‐filled steel tubes under static loading
...Show More Authors
Abstract<p>The purpose of this study is to examine the experimental, numerical, and analytical behavior of a novel class of composite columns. These columns are designed to replace conventional deformed steel bars with small circular steel tubes filled with cementitious grouting material in a longitudinal orientation. Twelve concrete columns in all were assembled and tested under various loading scenarios. These columns were evaluated under concentric compression load, two eccentric compression loads (25 or 50 mm), and flexural load. They included various forms of reinforcement in a longitudinal direction, including steel bars or tubes. A developed three‐dimensional finite element analysis utilizing the ABAQUS software and a suggested nonlinear sectional analysis methodology was validated using tested specimens. The test findings showed that the columns reinforced with 16 mm diameter steel tubes, whose wall cross‐sectional area is equal to 30% of the steel bar's area, were able to attain an ultimate capacity that was 77% of the conventional column specimens. Furthermore, compared to specimens reinforced with steel bars, the experimental load capacity of the specimens with 25.4 mm diameter steel tubes reinforcement—where the tube's wall cross‐sectional area and the steel bar have the equivalent area—was marginally higher. Finally, the proposed analytical methodology and the developed FE model employed in this study can accurately replicate the behavioral histories of concrete columns evaluated under various loading circumstances.</p>
View Publication
Publication Date
Mon Jan 11 2021
Journal Name
Engineering, Technology & Applied Science Research
The Effect of Low Velocity Impact Loading on SelfCompacting Concrete Reinforced with Carbon Fiber Reinforced Polymers
...Show More Authors

t-Self-Compacting Concrete (SCC) reduces environmental noise and has more workability. This research presents an investigation of the behavior of SCC under mechanical loading (impact loading). Two types of cement have been used to produce SCC mixtures, Ordinary Portland Cement (OPC) and Portland Limestone Cement (PLC), which reduces the emission of carbon dioxide during the manufacturing process. The mixes were reinforced with Carbon Fiber Reinforced Polymer (CFRP) which is usually used to improve the seismic performance of masonry walls, to replace lost steel reinforcements, or to increase column strength and ductility. Workability tests were carried out for fresh SCC. Prepared concrete slabs of 500×500×50mm were tested for lo

... Show More
Publication Date
Wed Mar 29 2023
Journal Name
Materials
Prediction of the Bending Strength of a Composite Steel Beam–Slab Member Filled with Recycled Concrete
...Show More Authors

This study investigated the structural behavior of a beam–slab member fabricated using a steel C-Purlins beam carrying a profile steel sheet slab covered by a dry board sheet filled with recycled aggregate concrete, called a CBPDS member. This concept was developed to reduce the cost and self-weight of the composite beam–slab system; it replaces the hot-rolled steel I-beam with a steel C-Purlins section, which is easier to fabricate and weighs less. For this purpose, six full-scale CBPDS specimens were tested under four-point static bending. This study investigated the effect of using double C-Purlins beams face-to-face as connected or separated sections and the effect of using concrete material that contains different recycled

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Mon Feb 24 2025
Journal Name
Advances In Structural Engineering
Experimental and numerical investigation on the behavior of composite reinforced concrete columns encased by steel section and hybrid GFRP section
...Show More Authors

GFRP was employed in constructions as an alternative to steel, which has many advantages like lightweight, large tensile strength and resist corrosion. Existing researches are insufficient in studying the influence of hybrid reinforced concrete composite columns encased by GFRP I-section (RCCCEG) and I-section steel (RCCCES). In this study twenty one (RC) specimens of a cross-section of 130 mm × 160 mm, with different length (long 1600 mm and short 750 mm) were encased by using I-section (steel and GFRP) and tested under various loading (concentric, eccentric and flexural loads). The test was focused on the influence of many parameters; load-carrying capacity, mode of failure, deformation and drawing an interaction diagram (N-

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2018
Journal Name
International Journal Of Civil Engineering And Technology (ijciet)
INTERACTION DIAGRAM FOR A REINFORCED CONCRETE COLUMN STRENGTHENED WITH STEEL JACKET
...Show More Authors

In this study, the construction of axial load-bending moment interaction diagrams for a reinforced concrete column and a steel jacket column has been presented. For a reinforced concrete column strengthened with a steel jacket consist of vertical steel sections connected by horizontal steel plates (battens), the axial load-bending moment interaction diagrams have been constructed using two analytical methods: strain compatibility method and plastic stress distribution method. In the strain compatibility method, the effects of position of the neutral axis on the stress of concrete, reinforcing bars, and steel section have been taken into consideration. In the plastic stress distribution method, the position of the neutral axis has no effect

... Show More
View Publication
Publication Date
Fri May 21 2021
Journal Name
Transportation Infrastructure Geotechnology
Behavior of Floating Stone Columns and Development of Porewater Pressure Under Cyclic Loading
...Show More Authors

View Publication Preview PDF
Scopus (24)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Jun 03 2018
Journal Name
Civil Engineering Journal
Finite Element Modeling of a Reinforced Concrete Column Strengthened with Steel Jacket
...Show More Authors

The reinforced concrete column is designed to have a nominal axial resistance. Under different conditions like errors in design, and changing the use of the building from residential to public or storage (extra live loads), the reinforced concrete column will not be able to sustain the desired applied load, and the strengthening is required. This paper presents a finite element model to simulate and investigate the behavior of adding steel jacket to a preloaded and non-damaged reinforced concrete column. Depending on the loading state of the non-strengthened reinforced concrete column and the purpose of adding the steel jacket, two possible cases have been studied. In the first case, which is suitable to investigate the reinforced c

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Sat Apr 11 2009
Journal Name
Journal Of Kerbala University
Evaluation The Behaviour of Reinforced Loose Sand under Inclined Loading
...Show More Authors

Publication Date
Mon Jul 01 2013
Journal Name
Journal Of Engineering
Behavior of Reinforced Gypseous Soil Embankment Model under Cyclic Loading
...Show More Authors

The construction of embankment for roadway interchange system at urban area is restricted due to the large geometry requirements, since the value of land required for such construction is high, and the area available is limited as compared to rural area. One of the optimum solutions to such problem is the earth reinforcement technique which requires a limited area for embankment construction. Gypseous soil from Al-Anbar governorate area was obtained and subjected to various physical and chemical analysis to determine it is properties. A laboratory model box of 50x50x25 cm was used as a representative embankment; soil has been compacted in five layers at maximum dry density (modified compaction) and an aluminum reinforcement strips we

... Show More
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Behavior of Reinforced Gypseous Soil Embankment Model under Cyclic Loading
...Show More Authors

The construction of embankment for roadway interchange system at urban area is restricted due to the large geometry requirements, since the value of land required for such construction is high, and the area available is limited as compared to rural area. One of the optimum solutions to such problem is the earth reinforcement technique which requires a limited area for embankment construction. Gypseous soil from Al-Anbar governorate area was obtained and subjected to various physical and chemical analysis to determine it is properties. A laboratory model box of 50x50x25 cm was used as a representative embankment; soil has been compacted in five layers at maximum dry density (modified compaction) and an aluminum reinforcement strips were i

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jul 27 2023
Journal Name
Buildings
Structural Behavior of Reactive Powder Concrete under Harmonic Loading
...Show More Authors

Industrial buildings usually are designed to sustain several types of load systems, such as dead, live, and dynamic loads (especially the harmonic load produced by rotary motors). In general, these buildings require high-strength structural elements to carry the applied loads. Moreover, Reactive Powder Concrete (RPC) has been used for this purpose because of its excellent mechanical strength and endurance. Therefore, this study provides an experimental analysis of the structural behaviors of reinforced RPC beams under harmonic loads. The experimental program consisted of testing six simply supported RPC beams with lengths of 1500 mm, widths of 150 mm, and thicknesses of 200 mm under harmonic loading with varied frequencies between 1

... Show More
Scopus (9)
Crossref (10)
Scopus Clarivate Crossref