Preferred Language
Articles
/
mnlqmKEBuRolNscLJwVZ
Electrochemical Analysis: Highly Selective Determination of Tenoxicam in Pharmaceutical and Environmental Samples Using a Molecularly Imprinted Polymer-Based Potentiometric Electrochemical Sensor
...Show More Authors

A highly selective potentiometric method for the determination of tenoxicam (TEX) was developed based on molecularly imprinted polymer (MIP) membrane electrodes. This s‌ tudy contributes to the field of analytical chemis‌ try by designing advanced electrochemical sensors for pharmaceutical analysis. The tenoxicam-imprinted polymers (TEX-MIPs) were synthesized using tenoxicam as the template molecule, allyl chloride as the functional monomer, trimethylolpropane triacrylate (TMPTA) as the cross-linking agent, and benzoyl peroxide (BP) as the radical initiator. Poly(vinyl chloride) (PVC)-based membranes were fabricated incorporating various plas‌ ticizers, namely oleic acid (O.A), paraffin (PRF), tri-butyl phosphate (TBP), and di-butyl sebacate (DBS), and subsequently employed to cons‌ truct potentiometric electrochemical sensors. The fabricated TEX-MIP electrodes exhibited near-Nerns‌ tian slopes of 42.6-52.7 mV per decade over a linear concentration range of 1.0 × 10⁻⁵ to 1.0 × 10⁻¹ M. These analytical characteris‌ tics demons‌ trate the suitability of the proposed electrochemical sensing platform for quantitative analysis in modern analytical chemis‌ try. The sensors demons‌ trated s‌ table and reproducible responses within a wide pH range (3–9). Selectivity s‌ tudies conducted in the presence of common pharmaceutical excipients, including benzoic acid, sodium benzoate, methyl paraben, and glucose, confirmed the high selectivity of the proposed electrodes toward tenoxicam. The obtained results indicate that TEX-MIP-based membrane electrodes provide a reliable, sensitive, and selective electrochemical analytical platform for the potentiometric determination of tenoxicam in pharmaceutical formulations and environmental samples.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Potentiometric Transducers for the Selective Recognition of Risperidone Based on Molecularly Imprinted Polymer
...Show More Authors

          Graphite Coated Electrodes (GCE) based on molecularly imprinted polymers were fabricated for the selective potentiometric determination of Risperidone (Ris). The molecularly imprinted (MIP) and nonimprinted (NIP) polymers were synthesized by bulk polymerization using (Ris.) as a template, acrylic acid (AA) and acrylamide (AAm) as monomers, ethylene glycol dimethacrylate (EGDMA) as a cross-linker and benzoyl peroxide (BPO) as an initiator. The imprinted membranes and the non-imprinted membranes were prepared using dioctyl phthalate (DOP) and Dibutylphthalate (DBP) as plasticizers in PVC matrix. The membranes were coated on graphite electrodes. The MIP electrodes using

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
A Sensitive Electrochemical Sensor for Rapid Determination of Mebeverine Hydrochloride and Metronidazole Benzoate Selective Molecular Imprinted Polymer in the PVC Membrane
...Show More Authors

Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.: SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.
...Show More Authors

Two molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared.  The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid  electrodes were packed with 0.1 M standar

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF THE NEW NAPROXEN SELECTIVE ELECTRODE BASED ON IMPRINTED POLYMER USING DIFFERENT MONOMERS AND ITS DETERMINATION AT PHARMACEUTICAL PREPARATION: SYNTHESIS OF THE NEW NAPROXEN SELECTIVE ELECTRODE BASED ON IMPRINTED POLYMER USING DIFFERENT MONOMERS AND ITS DETERMINATION AT PHARMACEUTICAL PREPARATION
...Show More Authors

ABSTRACT

Naproxen(NPX) imprinted liquid electrodes of polymers are built using polymerization precipitation. The molecularly imprinted (MIP) and non imprinted (NIP) polymers were synthesized using NPX as a template. In the polymerization precipitation involved, styrene(STY) was used as monomer, N,N-methylenediacrylamide (N,N-MDAM) as a cross-linker and benzoyl peroxide (BPO) as an initiator. The molecularly imprinted membranes and the non-imprinted membranes were prepared using acetophenone(AOPH) and di octylphathalate(DOP)as plasticizers in PVC matrix. The slopes and detection limits of the liquid electrodes ranged from)-18.1,-17.72 (mV/decade and )4.0 x 10-

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS NEW LIQUID ELECTRODES FOR DETERMINATION DOMPERIDONE MALEATE BASED ON A MOLECULARLY IMPRINTED POLYMER: SYNTHESIS NEW LIQUID ELECTRODES FOR DETERMINATION DOMPERIDONE MALEATE BASED ON A MOLECULARLY IMPRINTED POLYMER
...Show More Authors

Liquid electrodes of domperidone maleate (DOMP) imprinted polymer were synthesis based on precipitation polymerization mechanism. The molecularly imprinted (MIP) and non-imprinted (NIP) polymers were synthesized using DOMP as a template. By methyl methacrylate (MMA) as monomer, N,Nmethylenebisacrylamide (NMAA) and ethylene glycol dimethacrylate (EGDMA) as cross-linkers and benzoyl peroxide (BP) as an initiator. The molecularly imprinted membranes were synthesis using acetophenone (APH), di-butyl sabacate (DBS), Di octylphthalate (DOPH) and triolyl phosphate (TP)as plasticizers in PVC matrix. The slopes and limit of detection of l

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Biocatalysis And Agricultural Biotechnology
Determination of Diazinon in fruit samples using electrochemical sensor based on carbon nanotubes modified carbon paste electrode
...Show More Authors

View Publication
Scopus (59)
Crossref (51)
Scopus Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.: ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.
...Show More Authors

For aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 26 2022
Journal Name
Iraqi Journal Of Science
Potentiometric Determination of Mebeverine Hydrochloride Using Imprinted Molecular Polymer in PVC Matrix Membrane‏
...Show More Authors

Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Chem Tech Research
Synthesis of New Selective Electrodes for the Determination of Metronidazole Benzoate (MNZB) Based on a Molecularly Imprinted Polymer Combined With Poly Vinyl Chloride
...Show More Authors

Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Mefenamic Acid Selective Membranes Sensor and Its Application to pharmaceutical Analysis
...Show More Authors

PVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,

... Show More
View Publication Preview PDF
Crossref