Preferred Language
Articles
/
jkmc-268
The Value of Diffusion Weighted MRI in the Detection and Localization of Prostate Cancer among a Sample of Iraqi Patients
...Show More Authors

Background: Prostatic adenocarcinoma is the most widely recognized malignancy in men and the second cause of cancer-related mortality encountered in male patients after lung cancer.

Aim of the study:  To assess the diagnostic value of diffusion weighted imaging (DWI) and its quantitative measurement, apparent diffusion coefficient (ADC), in the identification and localization of prostatic cancer compared with T2 weighted image sequence (T2WI).

Type of the study: a prospective analytic study

Patients and methods: forty-one male patients with suspected prostatic cancer were examined by pelvic MRI at the MRI department of the Oncology Teaching Hospital/Medical City in Baghdad from September 2017 to September 2018. Thin sections axial T2 and DWI sequences were performed for each patient. Two patients were excluded from the study due to poor image quality (motion artefact). Regions with hypointense signal on T2WI and/or restricted lesion in DWI were determined. The ADC values were measured and the results were registered and sent for biopsy correlation. The sensitivity, specifity, accuracy and other parameters were calculated for T2WI and DWI.

Results: The sensitivity and specifity of T2WI in the detection of prostate cancer was about 76.6% and 77% respectively. These improved to 96% and 88.8% by performing the DWI and measuring the ADC value. The mean ADC value was greatly lower in prostatic cancer (about 650x 10-6 mm2 /s) than in normal prostate parenchyma (about 1250 x10-6 mm2 /s) with significant difference between them (p value about 0.04)

Conclusion: In practice, using diffusion weighted MRI sequence and its ADC quantitative measurement greatly increases tumor detection in patients suspicious to have prostatic cancer and should be routinely used when doing pelvic MRI for patients with high clinical suspicion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Common diskcyclic vectors
...Show More Authors

In this paper, we study the common diskcyclic vectors for a path of diskcyclic operators. In particular, if  is a path of diskcyclic operators, we show that under certain conditions the intersection of diskcyclic vectors for theses operators is a dense  set.

View Publication Preview PDF
Crossref
Publication Date
Sun Jan 26 2020
Journal Name
Journal Of Global Pharma Technology
Synthesis, Characterization of 2-azido-4-(azido (2-azido-2-( azido carbonyl)-1,3-dioxoian-4-yl)methyl)– 5-((R-azido (hydroxyl) methyl- 1,3-dioxole-2-carbonyl azide. ethanol. hydrate (L-AZD) with Some Metal Complexes
...Show More Authors

The reaction oisolated and characterized by elemental analysis (C,H,N) , 1H-NMR, mass spectra and Fourier transform (Ft-IR). The reaction of the (L-AZD) with: [VO(II), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II)], has been investigated and was isolated as tri nuclear cluster and characterized by: Ft-IR, U. v- Visible, electrical conductivity, magnetic susceptibilities at 25 Co, atomic absorption and molar ratio. Spectroscopic evidence showed that the binding of metal ions were through azide and carbonyl moieties resulting in a six- coordinating metal ions in [Cr (III), Mn (II), Co (II) and Ni (II)]. The Vo (II), Cu (II), Zn (II), Cd (II) and Hg (II) were coordinated through azide group only forming square pyramidal

... Show More
Publication Date
Thu Dec 23 2021
Journal Name
Iraqi Journal Of Science
Theoretical Biosensor Design for Gold- PVA Surface Plasmon Resonance Layers
...Show More Authors

. Surface Plasmon Resonance (SPR) technology has been adapted to produce a sensitive optical sensor and Biosensor applications. Simulation analysis ( in Matlab) has been made for SPR for gold (Au) layer with thickness (40 nm) and Polyvinyl Alcohol (PVA) polymer with various thickness (10, 20, 30, 40, 50, 60, 70 and 80 nm) deposited on glass prism type D-ZLAF50_Dense lanthanum flint. The sensitive layer was air (n=1). The analysis was taken for different wavelengths from Ultra-Violet wavelength 100 nm to Near Infra- Red wavelength 1000 nm. The properties of θSPR have been calculated from plotted reflectance against incident angle θincid.. The SPR sensitivity (S) was calculated. The results give efficient detection in chan

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Optical Fiber Biomedical Sensor Based on Surface Plasmon Resonance
...Show More Authors

Optical fiber biomedical sensor based on surface plasmon resonance for measuring and sensing the concentration and the refractive index of sugar in blood serum is designed and implemented during this work. Performance properties such as signal to noise ratio (SNR), sensitivity, resolution and the figure of merit were evaluated for the fabricated sensor. It was found that the sensitivity of the optical fiber-based SPR sensor with 40 nm thick and 10 mm long Au metal film of the exposed sensing region is 7.5µm/RIU, SNR is 0.697, figure of merit is 87.2 and resolution is 0.00026. The sort of optical fiber utilized in this work is plastic optical fiber with a core diameter of 980 µm, a cladding of 20μm, and a numerical aperture of 0.

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (10)
Scopus Crossref
Publication Date
Wed Sep 02 2020
Journal Name
Indonesian Journal Of Chemistry
Synthesis, Characterization and Biological Efficacies from Some New Dinuclear Metal Complexes for Base 3-(3,4-Dihydroxy-phenyl)-2-[(2-hydroxy-3-methylperoxy-benzylidene)-amino]-2-methyl Propionic Acid
...Show More Authors

The reaction of methyldopa with o-vanillin in refluxing ethanol afforded Schiff base and characterized through physical analysis with a number of spectra also the study of biological activity. The geometry of the Schiff base was identified through using (C.H.N) analysis, Mass, 1H-NMR, FT-IR, UV-Vis spectroscopy. Metal complexes of Cr3+, Mn2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+ and Hg2+ with Schiff base have been prepared in the molar ratio 2:1 (Metal:L), (L = Schiff base ligand) except Hg2+ at molar ratio 1:1 (Hg:L). The prepared complexes were characterized by using Mass, FT-IR and UV-Vis spectral studies, on other than magnetic properties and flame atomic absorption, conductivity measurements. According to the results a dinuclear octahedral geo

... Show More
View Publication
Scopus (18)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jul 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis, Characterization and Biological Activity Study for Some New Metals Complexes with (3Z,3'E)-3,3'-(((2E,5E)-hexane-2,5-diylidene)bis(hydrazine-2,1-diylidene))bis(indolin-2-one)
...Show More Authors

Our recent work displays the successful preparation of Schiff_bases that carried out between hexane-2,5-dione and 2 moles of (Z)-3-hydrazineylideneindolin-2-one forming in Schiff-bases-(L), Which in turn allowed combining with each of the next metal ions: (M2+) = Ni, Mn, Zn, Cu and Co forming complexes_ in high stability. The formation of resulting Schiff_ bases (L) is detected spectrally using LC_Mss which gave approximately matching results with theoretical incomes, 1HNMR proves the founding of doublet signal of (2H) for 2NH, FTIR indicates the occurrence of two interfered imine bands and UV-VIS mean is also indecates the formation of ligand. On the other hand, complexes-based-Schiff were characterized using the s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Computers, Materials & Continua
Improving Video Watermarking through Galois Field <i>GF</i>(2<sup>4</sup>) Multiplication Tables with Diverse Irreducible Polynomials and Adaptive Techniques
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Magnetic Lens Design Using Analytical Target Field Function
...Show More Authors

Analytical field target function has been considered to represent the axial magnetic field distribution of double polepiece symmetric magnetic lens. In this article, with aid of the proposed target function, the syntheses procedure is dependent. The effect of the main two coffectin optimization parameters on the lens field distribution, polepieces shape, and the objective focal prosperities for lenses operated under zero magnification mode has been studied. The results have shown that the objective properties evaluated in sense of the inverse design procedure are in an excellent correspondence with that of analysis approach. Where the optical properties enhance as the field distribution of the electron lens distributed along a narrow axi

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Multi-Focus Image Fusion Based on Pixel Significance Using Counterlet Transform
...Show More Authors

Abstract

 The objective of image fusion is to merge multiple sources of images together in such a way that the final representation contains higher amount of useful information than any input one.. In this paper, a weighted average fusion method is proposed. It depends on using weights that are extracted from source images using counterlet transform. The extraction method is done by making the approximated transformed coefficients equal to zero, then taking the inverse counterlet transform to get the details of the images to be fused. The performance of the proposed algorithm has been verified on several grey scale and color test  images, and compared with some present methods.

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Hypothetical Method for Gamma Dose Rate Assessment to Conditioned Radioactive waste Container
...Show More Authors

Metallic solid radioactive waste class low level - short lived Radioactive Waste

(LL-SL RW) is the main type of radioactive waste generated from decommissioning operations. Transport, storage and disposal regulations require for gamma emitting radioactive waste (mainly by 137Csisotope), that the dose rate in the proximity of the container should stand below a certain threshold. Also, the conditioning technique (using cementation technique) based on certain matrix with specific ratios should be able to attenuate the gamma radiation activity to the minimum level or to acceptable dosage rate at distance of 1m from the container. In this paper ,in absence of suitable labs for waste package assessment ,hypothetical method&n

... Show More
View Publication Preview PDF