Preferred Language
Articles
/
jih-949
Excess Molar Volumes and Viscosities of Mixtures Containing Dimethylformamide (DMF) with benzene, o-xylene, 1, 4- Dioxane and Tetrahydrofuran at 298.15 K.
...Show More Authors

          Measurements of excess molar volumes VE , viscosities η , excess viscosities Δ ln η  and excess molar activation energies of viscous flow ΔGE , are reported for binary mixtures of dimethylformamide (DMF) with , benzene , o-xylene , 1,4- dioxane and tetrahydrofuran are reported from density and viscosity measurements at 298.15 k and at atmospheric pressure over the entire composition range . The excess values are positive for the mixture (DMF+ polar solvent) and negative deviation from ideality for the mixture (DMF + non-polar solvent) over the whole composition range and discussed in the light of molecular interaction in the mixture.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 08 2019
Journal Name
Journal Of Global Pharma Technology
Effect of Functionalized Graphene Oxide (FGO) on the Electrical and Dielectrical Properties of PVA Films
...Show More Authors

In the present work, nanocomposite of poly (vinyl alcohol) (PVA) incorporated with functionalized graphene oxide (FGO) were fabricated using casting method. PVA was dispersed by varying content of FGO (0.3, 0.5, 0.8, 1 wt %). The PVA- FGO nanocomposite was characterized by FT‐IR, FE-SEM and XRD. Frequency dependence of real permittivity (ε’), imaginary (ε’’) and a.c conductivity of PVA/FGO and PVA/GO nanocomposite were studied in the frequency range 100 Hz- 1 MHz. The experimental results showed that the values of real (ε’) and imaginary permittivity (ε’’) increased dramatically by increasing the FGO content in PVA matrix. PVA/ FGO (1 wt %) nanocomposite revealed higher electrical conductivity of 6.4×10-4 Sm-1 compared to

... Show More
Publication Date
Wed Jul 09 2025
Journal Name
Journal Of Baghdad College Of Dentistry
In-Vitro evaluation of load-deflection characteristics and force levels of nickel titanium orthodontic archwires
...Show More Authors

Background: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 21 2023
Journal Name
International Journal Of Professional Business Review
Analysis of the Impact of Six Sigma and Risk Management on Iraq's Energy Sector Metrology
...Show More Authors

Purpose: aims the study to show How to be can to enhance measurement management by incorporating a risk-based approach and the six sigma method into a more thorough assessment of metrological performance.   Theoretical framework: Recent literature has recorded good results in analyzing the impact of Six Sigma and risk management on the energy sector (Barrera García et al., 2022) (D'Emilia et al. 2015). However, this research came to validate and emphasize the most comprehensive assessment of metrological performance by integrating Risk management based approach and Six Sigma analysis.   Design/methodology/approach: This study was conducted in Iraqi petroleum refining companies. System quality is measured in terms of sigmas, and t

... Show More
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Evaluation of protein level’s changes in saliva and sera of Oral Squamous Cell Carcinoma patients
...Show More Authors

This study aimed to identify the changes in total protein in saliva and sera samples of patients with oral squamous cell carcinoma in comparison to those of healthy controls. These changes were followed using electrophoresis (PAGE). Meanwhile, determinations of albumin, globulin and albumin to globulin ratio were carried out on sera samples only.Two groups were the participants in the present study, 18 patients with Oral Squamous Cell Carcinoma (OSCC), and 20 ages and gender matched healthy controls.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Iraqi Journal Of Science
Cleavage of mucin and salivary agglutinin by partiallypurified protease from native strain of Streptococcus mutansan67
...Show More Authors

Scopus (6)
Scopus
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 19 2017
Journal Name
International Journal Of Advances In Chemical Engineering And Biological Sciences
Detection of Aflatoxin M1 in Pasteurized Canned Milk and Using of UV Radiation for Detoxification
...Show More Authors

The current study was designed to investigate the presence of aflatoxin M1 in 25 samples of pasteurized canned milk which collected randomly from some Iraqi local markets using ELISA technique. Aflatoxin M1 was present in 21 samples, the concentration of aflatoxin M1 ranged from (0.25-50 ppb). UV radiation (365nm wave length) was used for detoxification of aflatoxin M1 (sample with highest concentration /50 ppb of aflatoxin M1 in two different volumes ((25 & 50 ml)) for two different time (15 & 30 min) and 30, 60, 90 cm distance between lamp and milk layer were used for this purpose). Results showed that distance between lamp and milk layer was the most effective parameter in reduction of aflatoxin M1, and whenever the distance increase the

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Assessment of Elongation Percentage, Tensile, and Tear Strength of Filler Particles: An In Vitro Study
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Oct 27 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Impacts of Varied Injection Timing on Emission Levels, Combustion Efficiency, and Performance of Biodiesel Engines
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Iraqi Journal Of Applied Physics
Effect of Substrate Temperature on Characteristics and Gas Sensing Properties of Nb2O5/Si Thin Films
...Show More Authors

Thin films of Nb2O5 have been successfully deposited using the DC reactive magnetron sputtering technique to manufacture NH3 gas sensors. These films have been annealed at a high temperature of 800°C for one hour. The assessment of the Nb2O5 thin films structural, morphological, and electrical characteristics was carried out using several methods such as X-ray diffraction (XRD), atomic force microscopy (AFM), energy-dispersive X-ray spectroscopy (EDS), Hall effect measurements, and sensitivity assessments. The XRD analysis confirms the polycrystalline composition of the Nb2O5 thin films with a hexagonal crystal structure. Furthermore, the sensitivity, response time, and recovery time of the gas sensor were evaluated for the Nb2O5 thin film

... Show More