The research aims to develop the best possible design for the widely used Cassegrain telescope. The system consists of two models of different designs: (a) the telescope consists of a Maksutov lens, a spherical primary mirror, and a secondary mirror attached to the lens; (b) it consists of a Maksutov lens and a spherical primary mirror, plus a non-lens attached secondary mirror located between the lens and the primary mirror. The image was evaluated and analyzed using the analysis tools in Zemax software. The results of the two designs showed that the telescope whose secondary mirrors are not adjacent to the Maksutov lens produces high quality image that is almost free from aberration, and then comes the telescope whose secondary mirrors are adjacent to the Maksutov lens in terms of image quality. In the first design, the tangential and sagittal axes in the MTF function of the remaining angles (0.1, 0.2, 0.3, 0.4, and 0.5) contain two curves, which show how the loss of symmetry has changed the value of the function for the two axes. In the second design, the sagittal and tangential axes are identical in the angles of incidence (0, 0.1, and 0.2), and the transverse and sagittal axes of the remaining angles (0.3, 0.4, and 0.5) contain two curves. In PSF for the first design, there are several pretty high peaks on the surface of the image at the angle of incidence (0, 0.1). Since the shape is regular, the point spread function indicates that there isn't an aberration, but in terms of the angles (0.2, 0.3, 0.4, 0.5), we observe a gradual loss in intensity and the appearance of elevations on both sides of the picture. In the second design, at the angles (0, 0.1, 0.2, 0.3), we observe in Figure 5 that there are several high peaks free from aberration.
A modified chemical method was used to prepare titanium dioxide nanoparticles (TiO2 NPs), which were diagnosed by several techniques: X-ray diffraction, Fourier transform infrared, field emission scaning electron microscopy, energy disperse X-ray, and UV-visible spectroscopy, which proved the success of the preparation process at the nanoscale level. Where the titanium oxide particles have an average particle size equal to 6.8 nm, titanium dioxide particles were used in the process of adsorption of Congo red dye from its aqueous solutions using a batch system. The titanium oxide particles gave an adsorption efficiency of Congo red dye up to more than 79 %. The experimental data of the adsorption process were analyzed with kinetic models and
... Show MoreIn this paper, Bayes estimators of Poisson distribution have been derived by using two loss functions: the squared error loss function and the proposed exponential loss function in this study, based on different priors classified as the two different informative prior distributions represented by erlang and inverse levy prior distributions and non-informative prior for the shape parameter of Poisson distribution. The maximum likelihood estimator (MLE) of the Poisson distribution has also been derived. A simulation study has been fulfilled to compare the accuracy of the Bayes estimates with the corresponding maximum likelihood estimate (MLE) of the Poisson distribution based on the root mean squared error (RMSE) for different cases of the
... Show MoreThe paper uses the Direct Synthesis (DS) method for tuning the Proportional Integral Derivative (PID) controller for controlling the DC servo motor. Two algorithms are presented for enhancing the performance of the suggested PID controller. These algorithms are Back-Propagation Neural Network and Particle Swarm Optimization (PSO). The performance and characteristics of DC servo motor are explained. The simulation results that obtained by using Matlab program show that the steady state error is eliminated with shorter adjusted time when using these algorithms with PID controller. A comparative between the two algorithms are described in this paper to show their effectiveness, which is found that the PSO algorithm gives be
... Show MoreThe optical detectors which had been used in medical applications, and especially in radioactive treatments, need to be modified studied for the effects of radiations on them. This study included preparation of the MnS thin films in a way that vacuum thermal evaporation process at room temperature 27°C with thickness (400+-10nm) nm and a sedimentation rate of 0.39nm/sec on glass floors. The thin films prepared as a detector and had to be treated with neutron irradiation to examine the results gained from this process. The results decay X-ray (XRD) showed that all the prepared thin films have a multi-crystalline structure with the dominance of the direction (111), the two samples were irradiated with a neutron irradiation source (241Am-9Be)
... Show MoreThis manuscript presents several applications for solving special kinds of ordinary and partial differential equations using iteration methods such as Adomian decomposition method (ADM), Variation iterative method (VIM) and Taylor series method. These methods can be applied as well as to solve nonperturbed problems and 3rd order parabolic PDEs with variable coefficient. Moreover, we compare the results using ADM, VIM and Taylor series method. These methods are a commination of the two initial conditions.
The Films of CdTe:Zn were prepared on a glass by using vacuum vapor deposition technique .The x-ray diffraction pattern revealed that the films have polycrystalline with FCC structure and the preferred orientation was along (111) plane. The films were exposed to a low dose of gamma ray.(5µCi for 30 days) Transmission and absorptance spectra were recorded in the range of (400-1100) nm before and after irradiation. It was found that irradiation has a clear effect on the optical and structural properties which include the transmition and absorption spectra, extinction coefficient, refractive index, and the energy gap.