Preferred Language
Articles
/
jih-3191
Fast New Method for Estimation of Captopril in Pure and Pharmaceutical Preparation by Reaction with Ammonium Ce (IV) Sulfate in Acid Medium
...Show More Authors

The determination of captopril (CAP) using a new continuous flow injection analysis (CFIA) method was given in this work CAP in its pure state and some of its pharmaceutical preparations. The technique can be described as simple, fast, sensitive, easy to operate, and low-cost. The CAP reacted with ammonium ceric(IV) sulfate (ACS)2(NH4 )2SO4Ce(SO4)2. 3 H2O in an acidic medium and the reaction led to the formation of a white, slightly yellowish precipitate. The formed precipitate was studied using Ayah 6S×1-ST-2D Solar cell-CFI Analyzer, a through the reflection of accident light on the surfaces of the precipitate particles at (0-1800), expressed as the response of the transducer measured in (mV). Some chemical and physical parameters were studied to provide the optimal conditions for the study. The calibration curve within the range of (0.07-3.0) mmol/L was linear, with a correlation coefficient (r) value equal to (0.9983), and the percentage value of linearity (R2%) was (99.65). The method's detection limit (L.O.D.) of the new method was 272.5 ng/25 µL; it was calculated by diluting the minimum concentration in the calibration curve gradually. RSD% was less than 0.2% for 0.9, 1.5, and 3.0 mmol/L concentrations of C.A.P. for n=8. The method was successfully applied to estimate C.A.P. in three pharmaceutical preparations, each produced by a different company. The new method was compared with the UV-Spectrophotometric method (classical method) at λmax= 207.2 nm by using the method of standard additions. Both the t-test and the F-test were conducted to ensure that there wasn't a significant difference between the new method and the conventional one. The results of both tests showed, at a confidence level of 95%, that there was no significant difference.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Biochemical Engineering Journal
Immobilization of mixed cells by Flaxseeds (Linum usitatissimum) extract as new nonconventional biocarrier for biodegradation of sodium dodecyl sulfate
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Wed Jun 20 2018
Journal Name
Al-academy
Directed by Treatment for single-place events in the cinematographic medium
...Show More Authors

The cinematographer mediates through the means of cinema and television a set of elements complementing each other in the light of developments in various sciences, culture and arts for the purpose of conveying the meaning to the recipient and achieve aesthetic taste. Despite the diversity of cinematographic media with its multiple forms, The researcher started from the principle of definition and knowledge of a technical phenomenon that emerged in the cinematographic medium through the treatment of dramatic events through the solutions of the exit line depends on the narrative of events in one place contributes to attract Mam spectator since this interesting phenomenon in the mediator, there .van question arises the adoption of that vis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 04 2025
Journal Name
Al-rafidain University College For Sciences
“Simple Regression Analysis by using Linear Programming Technique and illustration of Absolute Residuals method with another Estimation Techniques”
...Show More Authors

This research deals with unusual approach for analyzing the Simple Linear Regression via Linear Programming by Two - phase method, which is known in Operations Research: “O.R.”. The estimation here is found by solving optimization problem when adding artificial variables: Ri. Another method to analyze the Simple Linear Regression is introduced in this research, where the conditional Median of (y) was taken under consideration by minimizing the Sum of Absolute Residuals instead of finding the conditional Mean of (y) which depends on minimizing the Sum of Squared Residuals, that is called: “Median Regression”. Also, an Iterative Reweighted Least Squared based on the Absolute Residuals as weights is performed here as another method to

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 08 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
A Highly Sensitive Kinetic-Spectrophotometric Method for the Assay of Carbamazepine in Pure and Commercial Tablet
...Show More Authors

The study aimed to recommend a new spectrophotometric-kinetic method for determination of carbamazepine (CABZ) in its pure form and pharmaceutical forms. The proposed procedure based on the coupling of CABZ with diazotized sulfanilic acid in basic medium to yield a colored azo dye. Factors affecting the reaction yield were studied and the conditions were optimized. The colored product was followed spectrophotometrically via monitoring its absorbance at 396 nm. Under the optimized conditions, two method (the initial rate and fixed time (10 minute)) were applied for constructing the calibration graphs. The graphs were linear in concentration ranges 2.0 to 18.0 µg.mL-1 for both methods. The proposed was applied successfully in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Analysis of Vancomycin Hydrochloride in Pure and Pharmaceutical Injections via Batch and Cloud Point Extraction Techniques
...Show More Authors

Development of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sun Oct 10 2021
Journal Name
Journal Of Physics
A novel kite cross hexagonal search algorithm for fast block motion estimation
...Show More Authors

The performance quality and searching speed of Block Matching (BM) algorithm are affected by shapes and sizes of the search patterns used in the algorithm. In this paper, Kite Cross Hexagonal Search (KCHS) is proposed. This algorithm uses different search patterns (kite, cross, and hexagonal) to search for the best Motion Vector (MV). In first step, KCHS uses cross search pattern. In second step, it uses one of kite search patterns (up, down, left, or right depending on the first step). In subsequent steps, it uses large/small Hexagonal Search (HS) patterns. This new algorithm is compared with several known fast block matching algorithms. Comparisons are based on search points and Peak Signal to Noise Ratio (PSNR). According to resul

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Flow Injection Analysis with Turbidity Detection for the Quantitative Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations
...Show More Authors

The main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations.  A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for cell

... Show More
View Publication Preview PDF
Scopus (22)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Treatment of Sulfate in Sand by Using Magnetic Water Process
...Show More Authors

One of the most important problems in concrete production in Iraq and other country is the high sulfate content in sand that led to damage of concrete and hence reduces its compressive strength and may leads to cracking due to internal sulfate attack and delay ettringite formation. The magnetic water treatment process is adopted in this study. Many samples with different SO3 content are treated with magnetic water (12, 8, 4 and 2)L that needed for each 1kg of sand with the magnetic intensity (9000 and 5000) Gaus. The magnetic water needed is reduced with less SO3 content in sand. The ACI 211.1-91 concrete mix design was used in this research with slump range (75- 100) mm and the specified compressive strength (35MPa). The compressive streng

... Show More
Preview PDF