Cancer constitutes a serious disease and a major health problem in worldwide, a lot of people were infected with this dangerous disease, Therefore, there must be attention to this disease through diagnosis and prevention there. In this study, we determined the relationship between the Cancer and the concentration of trace elements by comparing the concentration trace elements for infected and non-infected people. The trace elements concentrations to nails are one of the diagnostic criteria that easily to detect and dated this disease without any harm to the patient. Eight nails samples were collected from cancer-infected and eight samples from non-infected of the relatives of first-degree. All samples were measured by the concentrations elements using X-ray fluorescence. The accuracy and precision were verified using standard samples. The results showed that the average concentrations of elements (Magnesium, silicon, potassium, calcium, ironand selenium,) were lower for cancer patients than their non-infected relatives and the trace elements (zinc, copper, cadmium, lead, chromium, manganese) were higher for cancer patients than their non-infected relatives. In conclusion, we need further studies to confirm the relationship between trace elements and cancer disease and attention the effect of diet and environmental risk of cancer.
X-rays fluorescence technology was used to measure the concentrations of trace and toxic elements in tobacco smoke. One sample local and eight samples were imported selected from Iraqi markets. The results proved that tobaccos contain few concentrations of element (calcium, potassium, sodium, manganese, magnesium, chlorine, and sulfur), trace concentrations of element (aluminum, vanadium, iron, cobalt, nickel, copper and zinc), and toxic concentrations of element (arsenic, selenium, bromine, antimony, cadmium, mercury and lead). Results are proved the concentrations of elements of samples are lower levels with the other countries in few element like (calcium, potassium, sodium and manganese), while the other elements were hi
... Show MoreIn this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral
... Show MoreIn this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA
The cement slurry is a mixture of cement, water and additives which is established at the surface for injecting inside hole. The compressive strength is considered the most important properties of slurry for testing the slurry reliability and is the ability of slurry to resist deformation and formation fluids. Compressive strength is governed by the sort of raw materials that include additives, cement structure, and exposure circumstances. In this work, we use micro silica like pozzolanic materials. Silica fume is very fine noncrystalline substantial. Silica fume can be utilized like material for supplemental cementations for increasing the compressive strength and durability of cement. Silica fume has very fine particles size less
... Show MoreThe simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of analytical signal of these substances are optimized. The obtained results of tetracycline drugs and injection solution B12 vitamin are in satisfactory agreement with data declared by the manufacturer.
Samples of tea leaves (Green tea, Gugarate tea and Black tea used commonly in Iraq) are dried, grinded, pressed and submitted for the elemental analysis by x-ray fluorescence technique (XRF). The concentrations of major, minor and trace elements are determined. The major elements were Na, Mg, Al, K, Si, Ca, Mn, Fe, S and P. Of these elements, Ca, concentration in Gugarate tea leaves is three times, it's level in the other types of tea. Titanium, Cl, Rb and Sr are found as minor elements, while other elements such as Cu, Zn, V, Cr, Co, ...etc are found as trace elements. Of these trace elements considerable concentration values are found for some toxic elements Hg, Cd, Pb and As. Green tea contains 1.1 ppm Hg and 4.4 ppm Pb. Gugarate tea
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreBackground: Nasopharyngeal carcinoma (NPC) is one of the most challenging tumors because of their relative inaccessibility and that their spread can occur without significant symptoms with few signs, but Radiotherapy (RT) has a role in treatment of it.
Objectives: To show that RT is still the modality of choice in the treatment of NPC, to study modes of presentations, commonest histopathological types and their percentages, to show differences in the sensitivities of these types to RT and to find out a 5 year survival rate(5YSR) and its relation with lymph node involvement.
Methods: This is a retrospective study of 44 patients with NPC who were treated with routine RT from 1988-2007 at the institute of radiology and nuclear medicin
n this study, data or X-ray images Fixable Image Transport System (FITS) of objects were analyzed, where energy was collected from the body by several sensors; each sensor receives energy within a specific range, and when energy was collected from all sensors, the image was formed carrying information about that body. The images can be transferred and stored easily. The images were analyzed using the DS9 program to obtain a spectrum for each object,an energy corresponding to the photons collected per second. This study analyzed images for two types of objects (globular and open clusters). The results showed that the five open star clusters contain roughly t
... Show MoreWith its rapid spread, the coronavirus infection shocked the world and had a huge effect on billions of peoples' lives. The problem is to find a safe method to diagnose the infections with fewer casualties. It has been shown that X-Ray images are an important method for the identification, quantification, and monitoring of diseases. Deep learning algorithms can be utilized to help analyze potentially huge numbers of X-Ray examinations. This research conducted a retrospective multi-test analysis system to detect suspicious COVID-19 performance, and use of chest X-Ray features to assess the progress of the illness in each patient, resulting in a "corona score." where the results were satisfactory compared to the benchmarked techniques. T
... Show More