Determination of the Degree of Consumption (DoC) of Lube Engine Oils Using Fluorescence Spectroscopy
...Show More Authors

    The accreditation of a fast, inexpensive, and simple way to discriminate between different kinds of oils and their efficacy “degree of consumption (DoC)” has been developed. The fluorescence spectroscopy provides a reliable method for oil inspection without resorting to tedious separation.

Different new and used oil samples available in the local Iraqi market were investigated. While the challenge is to build a directory containing data of all the oils available in the local market. This method expected to control the falsified (forged) trademarks of motor oils and to discriminate between different oils.

The excitation-emission spectra of oil samples were determined in the range of 200 – 600 nm. The effect of the presence of trace metals on the fluorescence intensity of oils was considered by adding few milligrams of (Cu, Al, Fe) to the diluted oil solution. No major effect noticed on fluorescence intensity.

The research suggests installing a simple Spectrofluorometer into vehicles to check the DoC of the oil regularly and to notify the driver exactly when to replace the engine oil.

The obtained results indicate the applicability to execute such gadget to be installed in the vehicles for routine detection of the engine oil quality and its degree of consumption DoC. As well as demonstrate the potential of the technique in oil identification and could be further developed.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Aromatic Hydrocarbons from Lube Oil Using Different Co-Solvent
...Show More Authors

An investigation was conducted effect of addition co- solvent on solvent extraction process for two types of a lubricating oil fraction (spindle) and (SAE-30) obtained from vacuum distillation unit of lube oil plant of Daura Refinery. In this study two types of co-solvents ( formamide and N-methyl, 2, pyrrolidone) were blended with furfural to extract aromatic hydrocarbons which are the undesirable materials in raw lubricating oil, in order to improve the viscosity index, viscosity and yield of produced lubricating oil. The studied operating condition are extraction temperature range from 70 to 110 °C for formamide and 80 to 120 °C for N-methyl, 2, pyrrolidone, solvent to oil ratio range from 1:1 to 2:1 (wt./wt.) for furfural with form

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 08 2019
Journal Name
Lubricants
Influence of Sample Mixing Techniques on Engine Oil Contamination Analysis by Infrared Spectroscopy
...Show More Authors

For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Aug 06 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Total luminescence (Chemiluminescence & Fluorescence)- FIA Method For The Determination of DL-Histidine
...Show More Authors

Histidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to  initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Determination of Active Phytochemical Compounds of Alhagi Maurorum using Gas Chromatography-Mass Spectroscopy (GC-MS)
...Show More Authors

Alhagi maurorum (camel thorn) is a grayish, evergreen, deeply rooting plant that has spiny needle -like branches. In our study, the phytochemical contents of the root ethanoloic extract of A. maurorum were determined by using gas chromatography-mass spectroscopy (GC-MS). Thirty two chemical constituents were identified. We revealed the existence of oxalic acid, anti-2 acetoxyacetaldoxime, sulfone, butyl isopropyl, 2,3-pentanedione, 2-butanone, n,n,o triacetylhydroxylamine. di(1,2,5-oxadiazole)[3,4-b;3,4-e]pyrazine, isobutane,3,4-hexanedione,3-hexanone, pentane, 3-pentanone, 3-butene, 2-thiopheneacetic acid, 2-pyrazoline, 4-hepten-3-onemethylphosphonic acid, butane, propanoic acid, methane, azetidine, heptane, butanoic a

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Wed Feb 08 2023
Journal Name
Iraqi Journal Of Science
Determination of oxonium ion and application via quenching of continuous fluorescence light (fluorescein salt) using I- -IO3--H3O+ system
...Show More Authors

The research work present a sensitive, accurate and fast developed for the determination of oxonium ion (HCl, H2SO4 , HClO4 and tartaric acid). It relies on the formation free iodine molecule from the I--IO3--H3O+ reaction which react with fluorescein sodium salt solution causing to quench the fluorescence light (continuous fluorescence) when irradiated by laser source at 405nm. Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used. The flow rate of 1.3 and 1.5 mL/min was used, 35μL sample volume no.1 and sample volume no.2 , linear dynamic range extend from 0.05-7, 0.05-7, 0.1-10 and 0.1-10 mMol.l-1 with correlation coefficient of 0.9933, 0.9964, 0.9984 and 0.9973 for HCl, H2

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
X-Ray Fluorescence Determination of Trace Elements in Vitamin-Mineral Complexes and Medicinal Herbs Using Chemically Modified Polyurethane Foam Sorbents
...Show More Authors

In this paper we proposed the method of X-ray fluorescence (XRF) determination of some essential trace elements in medicinal herbs and vitamin-mineral complexes at the level of 100-101 mg/ml. To increase sensitivity and selectivity of the determination we simple and effective approach based on the extraction of metal ions from aqueous solutions with chemically modified polyurethane foam sorbents followed by direct XRF analysis. The conditions of sorption preconcentration of Co(II), Ni(II) and Zn(II) ions with modified sorbents were optimized. The proposed approach is used for the determination of trace elements in several kinds of medicinal herbs (coltsfoot leaves, nettle leaves and yarrow herb) and vitamin-mineral

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 10 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Study on the effect of diesel engine oil contaminated with fuel on engine performance
...Show More Authors

An experiment was conducted to study how SAE 50 engine oil contaminated with diesel fuel affects engine performance. The engine oil was contaminated with diesel fuel at concentrations of 0%, 1%, and 3%. The following performance characteristics were studied: brake-specific fuel consumption, brake thermal efficiency, friction power, and exhaust gas temperature. Each treatment was tested three times. The three treatments (0%, 1%, and 3%) were analyzed statistically with a one-way ANOVA model at the 5% probability level to determine if the three treatments produced significant differences in engine performance. The statistical results showed that there were significant differences in engine performance metrics among the three treatments. The 3

... Show More
Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
The Rationalization of clothes consumption: The Rationalization of clothes consumption
...Show More Authors

Abstract
The study aims to recognize the degree of consumptions awareness of the
Iraqi family; the conscious and studied planning of the family; budget and the
object study of the rationalization s consumption.
The research study 100 specimens of both students and employees who
are housewives at the department of home economics of the college of
Education for women.
Questioner the items are 22.
One of the most important results that the study finds is the availability of
consumption's awareness's level particularly of low income families and
college degrees hdders who are over 35.
The study recommends the necessity of a conscious and studied
planning of the family's budget; its purchase and consumption

... Show More
View Publication Preview PDF
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication
Publication Date
Fri Jul 01 2022
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Ciprofloxacin by Quenched Fluorescence of Analytically Interested Species Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

The objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is

... Show More
View Publication Preview PDF