In this paper, we describe a new method for image denoising. We analyze properties of the Multiwavelet coefficients of natural images. Also it suggests a method for computing the Multiwavelet transform using the 1st order approximation. This paper describes a simple and effective model for noise removal through suggesting a new technique for retrieving the image by allowing us to estimate it from the noisy image. The proposed algorithm depends on mixing both soft-thresholds with Mean filter and applying concurrently on noisy image by dividing into blocks of equal size (for concurrent processed to increase the performance of the enhancement process and to decease the time that is needed for implementation by applying the proposed algorithm on all four blocks concurrently) which are employed in order to remove the noise. The proposed method of image retrieving and smoothing outperforms the conventional methods that are used for image enhancement. The suggested algorithm and the evaluation test carried using Delphi V.5 package
Background: In dentistry, dentist takes the advantages of soft lining materials due to the viscoelastic properties. The major problem is the adhesion of the soft liner with the denture base material. Materials and Methods: Heat cured of high impact acrylic resin specimens prepared with dimensions 75x13x13mm for shear bond strength test, soft lining material (Refit and Mollosil) with a 3-mm thickness and used to join each two acrylic blocks. Also four specimens with the same previous dimensions utilized for chemical and physical surface analysis. The specimens grouped as control (without plasma) and experiment (with oxygen plasma) treated high impact acrylic specimens. Results: Plasma treatment increased the shear bond strength for both Refi
... Show MoreAcute appendicitis is the most common surgical abdominal emergency. Its clinical diagnosis remains a challenge to surgeons, so different imaging options were introduced to improve diagnostic accuracy. Among these imaging modality choices, diagnostic medical sonography (DMS) is a simple, easily available, and cost effective clinical tool. The purpose of this study was to assess the accuracy of DMS, in the diagnosis of acute appendicitis compared to the histopathology report, as a gold standard. Between May 2015 and May 2016, 215 patients with suspected appendicitis were examined with DMS. The DMS findings were recorded as positive and negative for acute appendicitis and compared with the histopathological results, as a gold standard
... Show MoreBackground: The purposes of this study were to determine the photogrammetric soft tissue facial profile measurements for Iraqi adults sample with class II div.1 and class III malocclusion using standardized photographic techniques and to verify the existence of possible gender differences. Materials & methods: Seventy five Iraqi adult subjects, 50 class II div.1 malocclusion (24 males and 26 females), 25 class III malocclusion (14 males and 11 females), with an age range from 18-25 years. Each individual was subjected to clinical examination and digital standardized right side photographic records were taken in the natural head position. The photographs were analyzed using AutoCAD program 2007 to measure the distances and angles used in t
... Show MoreA new computer-generated optical element called a monochrome image hologram (MIH) is described. A real nonnegative function to represent the transmittance of a synthesized hologram is used. This technique uses the positions of the samples in the synthesized hologram to record the phase information of a complex wavefront. Synthesized hologram is displayed on laser printer and is recorded on a film. Finally the reconstruction process is done using computerized .
Medical image security is possible using digital watermarking techniques. Important information is included in a host medical image in order to provide integrity, consistency, and authentication in the healthcare information system. This paper introduces a proposed method for embedding invisible watermarking in the 3D medical image. The cover medical image used is DICOM which consists of a number of slices, each one representing a sense, firstly must separate the ROI (Region of Interest) and NROI (Not Region Of Interest) for each slice, the separation process performed by the particular person who selected by hand the ROI. The embedding process is based on a key generated from Arnold's chaotic map used as the position of a pixel in
... Show MoreIn this paper, we will focus to one of the recent applications of PU-algebras in the coding theory, namely the construction of codes by soft sets PU-valued functions. First, we shall introduce the notion of soft sets PU-valued functions on PU-algebra and investigate some of its related properties.Moreover, the codes generated by a soft sets PU-valued function are constructed and several examples are given. Furthermore, example with graphs of binary block code constructed from a soft sets PU-valued function is constructed.
Random throwing of industrial waste has a significant impact on the environment unless it takes into account the conditions of engineered destroying and/or re-used. Taking the advantage of re-using waste materials in engineering projects represents a well-planned project in order to resolve a lot of engineering problems for some difficult soils. The objective of this study was to evaluate the capability and effects of Rubber Shreds (RS) from scrap torn belts towards improving the shear strength of soft clay. A direct shear tests were conducted on soft clay-RS mixture. The following parameters were investigated to study the influence of RS content, water content, normal stress, and dilation ratio. From experimental test results it was fou
... Show MoreFunctionally graded materials (FGMs), with ceramic –ceramic constituents are fabricated using powder technology techniques. In this work three different sets of FGMs samples were designed in to 3 layers, 5 layers and 7 layers. The ceramic constituents were represented by hard ferrite (Barium ferrite) and soft ferrite (lithium ferrite). All samples sintered at constant temperature at 1100oC for 2 hrs. and characterized by FESEM. Some physical properties were measured for fabricated FGMs include apparent density, bulk density, porosity, shrinkage and hardness. The results indicated that the density increase with the increase the number of layer. Lateral shrinkage is one of the important parameter f
... Show More