Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the thermocycling process and dipped in 2% methylene blue dye before being sectioned through the center of the restoration. Microleakage was evaluated digitally using software and a camera connected to a stereomicroscope (30 x magnification) to assess dye penetration of the sectioned samples at both the occlusal and gingival marginal levels. Results: There was a significant difference between the coated and uncoated groups at both occlusal (p=.029) and gingival margin sites (p=.001). Conclusion: Higher microleakage values were associated with the uncoated group compared to the coated one. The application of a protective coating to the restorations is an efficient approach to decrease the microleakage of the restorations that can be usefully adopted in clinical practice.
The preparation and spectral characterization of complexes for Co(II), Ni(II), Cu(II), Cd(II), Zn(II) and Hg(II) ions with new organic heterocyclic azo imidazole dye as ligand 2-[(2`-cyano phenyl) azo ]-4,5-diphenyl imidazole ) (2-CyBAI) were prepared by reacting a dizonium salt solution of 2-cyano aniline with 4,5-diphenyl imidazole in alkaline ethanolic solution .These complexes were characterized spectroscopically by infrared and electronic spectra along with elemental analysis‚ molar conductance and magnetic susceptibility measurements. The data show that the ligand behaves a bidantate and coordinates to the metal ion via nitrogen atom of azo and with imidazole N3 atom. Octahedral environment is suggested for all metal complex
... Show MoreNew bidentate Schiff base ligand (L) namely [(Z)-3-(2-oxoindolin-3ylildeneamino)benzoic acid] type (NO) was prepared via condensation of isatin and 3-amino benzoic acid in ethanol as a solvent in existence of drops of (glac. CH3COOH). The new ligand (L) was characterized base on elemental microanalysis, FT-IR, UV-Vis, 1H-NMR spectra along with melting point. Ligand complexes in general formula [M(L)2Cl2]. H2O, where: MII = Co, Cu, Cd, and Hg; L= C15H10 N2O3 were synthesized and identified by FT-IR, UV-Vis, 1H-NMR (for Cd complex only) spectra, atomic absorption, chloride content along with molar conductivity and magnetic susceptibility. It was found that the ligand behaves as bidentate on complexation via (N) atom of imine group an
... Show MoreThe concealment of data has emerged as an area of deep and wide interest in research that endeavours to conceal data in a covert and stealth manner, to avoid detection through the embedment of the secret data into cover images that appear inconspicuous. These cover images may be in the format of images or videos used for concealment of the messages, yet still retaining the quality visually. Over the past ten years, there have been numerous researches on varying steganographic methods related to images, that emphasised on payload and the quality of the image. Nevertheless, a compromise exists between the two indicators and to mediate a more favourable reconciliation for this duo is a daunting and problematic task. Additionally, the current
... Show MoreThe process of converting coordinates is, still, considered an important and difficult issue due to the way of conversion from geographic ellipsoidal system to the projected flat system. The most common method uses contiguous UTM system as one of the most accurate systems in the conversion process, but the users of the
system face problems related to contiguity, especially at the large areas that lie within more than one zone. The aim of the present research is to solve the problem related to the multiple zones coverage found in the Iraqi territory using a mathematical model based on the use of Taylor series. The most accurate conversion equation used in this paper was based on the 4th order polynomial of two variables. The calculatio
In this work, the dynamic behavior of discrete models is analyzed with Beverton- Holt function growth . All equilibria are found . The existence and local stability are investigated of all its equilibria.. The optimal harvest strategy is done for the system by using Pontryagin’s maximum principle to solve the optimality problem. Finally numerical simulations are used to solve the optimality problem and to enhance the results of mathematical analysis
This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water. The filtration system was designed with two rotating interfered modules of these filters. Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs. The average measured hy
... Show MoreIn this research a new system identification algorithm is presented for obtaining an optimal set of mathematical models for system with perturbed coefficients, then this algorithm is applied practically by an “On Line System Identification Circuit”, based on real time speed response data of a permanent magnet DC motor. Such set of mathematical models represents the physical plant against all variation which may exist in its parameters, and forms a strong mathematical foundation for stability and performance analysis in control theory problems.
Background: During the past several years, there has been a rapidly escalating clinical need to perform IHC stains that require quantitative interpretation. Automated Cellular
Imaging System is used to analyze immunohistochemically stained slides, primarily for cancer-related diagnostics. Studies have shown that the device offers accuracy,
precision, and reproducibility of immunostained slide analysis exceeding that possible with manual evaluation, which was the prevailing method.
Aim of the study In this article we will demonstrate that meaningful image analysis of immunohistochemical staining studies can be performed using inexpensive, widely distributed
graphics software (Adobe Photoshop) on a personal
Synthesis of sedimentologic, paleocurrent, and organic geochemistry data of the Lower Permian Ga’ara Formation from the Western Desert, western Iraq, shows good hydrocarbon potentiality and deposition by high sinuosity and mixed-load channels, likely by a meandering river system. The Ga’ara Formation includes kaolinitic mudstone beds of various colors and channelized quartzitic sandstone beds. Based on the lithofacies identification, five lithofacies associations have been recognized: channel-floor, point-bar, abandoned channel plug, crevasse splay, and interchannel flood basin. In addition, the paleocurrent analysis and sandstone percentage map indicate a variation of the paleoflow spatially and temporally with a general di
... Show MoreTo damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The res
... Show More