Preferred Language
Articles
/
jbcd-2872
Comparison among pulp capping materials in: calcium ion release, pH change, solubility and water sorption (An in vitro study)
...Show More Authors

Background: Calcium hydroxide and calcium-silicate materials used as direct pulp capping materials. The aims of this in vitro study is to compare among these materials in, the calcium ion release and pH change in soaking water after immersion of materials’ specimens in deionized water. Also Solubility and water sorption of materials’ specimens measured after soaking time. Calcium-silicate materials used were Biodentine, TheraCal and MTA Plus. Materials and methods: Four materials used in this study; Urbical lining (as control group), Biodentine, TheraCal and MTA Plus. Ten discs fabricated from each tested material, by using plastic moulds of 9 mm diameter and 1 mm thickness. Each specimen was immersed in 10 ml of deionized water and stored at 37ºC using incubator for 3 hr, 24hr, 14 days and 30 days as a sequence. The amount of calcium ion (Ca+2) released in soaking water was measured in each tube using atomic absorption spectrophotometer. Also pH analysis for soaking water measured by using pH meter. For solubility and water sorption measurement, the specimen (n=10) weighed with precision weighing scale before immersion in deionzed water to determine the initial Weight (W1) and immediately after weighing immersed in 10 mL of deionized water at 37 °C for 1 week using an incubator, then removed and weighing again (W2). The samples blotted dry using filter paper and dehydrated in an oven at 37 °C for 24 hr. and weighed again (W3). Then percentage of solubility and water sorption were determined. Data obtained were analyzed using one-way ANOVA and Tukey tests at 0.05 significant levels. Results: Statistical analysis showed highly significant differences (P<0. 05) among tested materials and in all tests (Ca+2 release, pH change, solubility and water sorption). Biodentine showed higher calcium ion released at four soaking time (3 hr, 24hr, 14 days and 30 days), with non significant difference with TheraCal and highly significant difference with MTA Plus and control group at 24 hr. immersion time; While MTA Plus showed non significant difference with control group at 24 hr. Less amount of calcium released was in control group. All tested materials induced alkalization of the soaking water that decreased with time. Means of solubility and water sorption showed that MTA Plus and biodentine had higher solubility in comparison with control group, while TheraCal showed less solubility than control group. The results of water sorption showed that less sorption percentage occurred in control group in comparison with other groups. Conclusion: calcium-silicate materials released more Ca+2 with time than calcium hydroxide. TheraCal showed less solubility and higher water sorption in comparison with control group. Biodentine and MTA Plus showed higher solubility and water sorption in comparison with TheraCal and control group.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Evaluation of the Impact of Ozonated Water on Water Sorption and Solubility of Heat Cure Acrylic Resin: An In Vitro Study
...Show More Authors

Introduction: This study aimed to evaluate the impact of ozonated water on water sorption and solubility of heat-cure acrylic resin. Methods: Thirty-three samples of heat-cured acrylic resin were manufactured and divided into three groups: control, immersion for 10 and 20 minutes in ozonated water. Water sorption and water solubility tests were carried out in line with ADA Standard No. 12 for denture-base acrylic resin. Data were analyzed using one-way ANOVA at a significance level of 5%. Results: There was a nonsignificant difference between the control and experimental groups regarding water sorption (P

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Wed Oct 14 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 01 2024
Journal Name
The Saudi Dental Journal
Different pulp capping agents and their effect on pulp inflammatory response: A narrative review
...Show More Authors

View Publication
Scopus (9)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sat Jun 15 2019
Journal Name
Drug Invention Today
Mucoadhesive oral in situ gel of itraconazole using pH-sensitive polymers: Preparation, and in vitro characterization, release and rheology study
...Show More Authors

Publication Date
Wed Oct 14 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of the Solubility of Four Endodontic Sealers in Different Solvents (An In Vitro Study)
...Show More Authors

Background: Complete removal of filling material from the root canal is an essential requirement for endodontic retreatment. The purpose of the present study is to evaluate and compare the dissolving capabilities of various solvents (Xylene, Eugenate Desobturator, Eucalyptol, EDTA and Distilled water (as a control)) on four different types of sealer (Endofill, Apexit Plus, AH Plus and EndoSequence bioceramic sealer). Materials and method: Eighty samples of each sealer were prepared according to the manufacturers' instructions and then divided into ten groups (of 8 samples) for immersion in the respective solvents for 2 and 5 min immersion periods. Each sealer specimen was weighed to obtain its initial mass. The specimens were immersed in

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 14 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Dissolution of calcium ion from teeth treated with different concentrations of siwak water extract in comparison with sodium fluoride
...Show More Authors

Background: The miswak is a teeth cleaning twig made from a twig of the Salvadora persica tree (known as arak in Arabic).A traditional alternative to the modern toothbrush, it has a long, well-documented history and is reputed for its medicinal benefits. It also features prominently in Islamic hygienical jurisprudence. Materials and methods: Twenty maxillary first premolars were treated with the selected solutions which included siwak water extract (5%, 10%) and sodium fluoride 0.05% for 2minutes once daily for 20 days interval, deionized water was used as control negative. Then the concentration of the dissolved calcium ion in the etching solution of 2N HCL was measured. Results: The least amount of the dissolved calcium ion was registere

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Nanostructures
The Effects of Different Camphorquinone Concentrations on the Water Sorption and Solubility of an Experimental Green-Based Flowable Resin Composite
...Show More Authors

Water sorption (WS) and solubility (S) of the experimental flowable composites (EFCs), made from silica filler of rice husk are important to explore the reaction of EFCs against different oral environments. To investigate the effects of different camphorquinone concentrations on the WS and S of the EFCs. EFCs were fabricated from nanohybrid silica and involved different weights of camphorquinone (CQ) (0.03 g, 0.05 g and 0.075 g) and other materials. 3 groups of 7 disk-like samples of each of the three EFCs and Revolution Formula 2 (RF2) were tested. Before immersion, the volumes were recorded and the mass of each sample was recorded, as m1. During the immersion phase in three different media for 7 days, the weight was recorded as m2. During

... Show More
View Publication
Scopus (1)
Scopus
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Clinical And Experimental Dentistry
Performance of novel enamel-conditioning calcium-phosphate pastes for orthodontic bonding: An in vitro study
...Show More Authors

Background This study aimed to develop remineralizing calcium-phosphate (CaP) etchant pastes for enamel conditioning before bracket bonding and evaluate the bonding performance, failure pattern, and enamel surface integrity post bracket debonding in comparison with the conventional phosphoric acid (PA) etchant gel. Material and Methods Micro-sized monocalcium phosphate monohydrate and hydroxyapatite (micro- and nano-sized) powders were mixed with various phosphoric and nitric acid concentrations to develop eight acidic CaP pastes. Ninety extracted human premolars were randomly assigned into eight experimental and one control group (n=10). The developed pastes and control (commercial 37% PA-gel) were applied onto the enamel using the etch-a

... Show More
View Publication
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Sun Sep 28 2025
Journal Name
Polymers
Characterization of a Hydrogel Composite Containing Bioactive Moringa as a Novel Pulp-Capping Material
...Show More Authors

Hydrogels are hydrophilic biocompatible polymers that can be used as a drug delivery material in different medical branches, including vital pulp therapy. The aim of this study is to characterize the physical and biological properties of the newly developed formula as a candidate direct pulp-capping material. The hydrogel composite was prepared from natural and synthetic origins (polyvinyl alcohol (PVA), hyaluronic acid (HA), and sodium alginate (SA)) with the incorporation of bioactive Moringa. Different formulas of hydrogel containing different concentrations were evaluated for physicochemical (FTIR, XRD, SEM, degradation, and swelling), mechanical (viscosity, folding endurance, film thickness), and biological (antioxidant, antibacterial,

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref