Intramedullary Versus Extramedullary Alignment Guide for the Accurate Sagital Tibial Prosthesis Alignment in Total Knee Replacement Arthroplasty
...Show More Authors

Background: long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment, several studies have correlated poor outcome with malalignment of the components. The debate on the optimal system for femoral alignment is now largely resolved, but there is still controversy about whether intramedullary or extramedullary systems are better for the tibial side.

Objecives :  is to determine whether intramedullary or extramedullary tibial alignment guide is better for accurate sagital tibial prosthesis alignment in total knee replacement arthroplasty.

Patients and methods: Of 65 patients recruited, only 48 patients (55 knees) were met the inclusion criteria of this study (32 female and 16 male) with an average age of 62.2 years ranging from 57 to 70 years who had attended the outpatient clinic in medical city-orthopedic and trauma consultation unit and private work, during the period from October 2010 till March 2012. All patients were diagnosed to have severe osteoarthritis of their knees and we performed total knee replacement arthroplasty for them. Patients were divided into two groups, group A, were 22 patients (25 knees) in which we used intramedullary alignment guide for the preparation of proximal tibia, and group B, were 26 patients (30 knees) in which we used extramedullary alignment guide for the preparation of the proximal tibia. Three months postoperatively, a standing long leg proper lateral plain X-ray (digital software) was taken and the sagital tibial slope was measured for each case.

Results: Accurate alignment of sagital posterior slope of tibial prosthesis was found in 80% (20 out of 25 knees) in group A, and in 43.3% (13 out of 30 knees) in group B.By using Student t test, the P value was less than 0.001 which was very significant.

Conclusion: we concluded that the intramedullary tibial alignment guide is statistically more accurate than extramedullary tibial alignment guide, in the sagital positioning of the tibial component.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 20 2021
Journal Name
Key Engineering Materials
Effect of Partial Substitution of Sr by Ba on the Structural Properties of Tl<sub>0.8</sub>Ni<sub>0.2</sub>Sr<sub>2-x</sub>Br<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>9-δ</sub> System
...Show More Authors

In this manuscript, the effect of substituting strontium with barium on the structural properties of Tl0.8Ni0.2Sr2-xBrxCa2Cu3O9-δcompound with x= 0, 0.2, 0.4, have been studied. Samples were prepared using solid state reaction technique, suitable oxides alternatives of Pb2O3, CaO, BaO and CuO with 99.99% purity as raw materials and then mixed. They were prepared in the form of discs with a diameter of 1.5 cm and a thickness of (0.2-0.3) cm under pressures 7 tons / cm2, and the samples were sintered at a constant temperature o

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Oct 28 2018
Journal Name
Journal Of Planner And Development
أثر المعالم في الفضاء الحضري المعالم (الأبنية) كنواة لتنظيم الفضاء الحضري
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jul 31 2021
Journal Name
Iraqi Journal Of Science
Enhancement of Spectrum Sensing Performance via Cooperative Cognitive Radio ‎Networks at Low SNR
...Show More Authors

     The inefficient use of spectrum is the key subject to overcome the upcoming spectrum crunch issue. This paper presents a study of performance of cooperative cognitive network via hard combining of decision fusion schemes. Simulation results presented different cooperative hard decision fusion schemes for cognitive network. The hard-decision fusion schemes provided different discriminations for detection levels. They also produced small values of Miss-Detection Probability at different values of Probability of False Alarm and adaptive threshold levels. The sensing performance was investigated under the influence of channel condition for proper operating conditions. An increase in the detection performance was achi

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref