Background: This study was conducted in pursuit of gaining an understand effects of the low level laser irradiation on whole blood is very essential way in revealing the mechanisms of the action of laser radiation on biological tissues.
Objective: The purpose of this study is to investigate the in vitroeffect of laser radiation on some hematological parameters and erythrocyte sedimentation rate.
Subject and Method: Blood samples were obtained from 30 healthy volunteers, each sample was divided into four new samples, one of them was considered as control while the other three were exposed to three different laser doses. Thewavelength of532nm was used for irradiation with 4mm diameter beam spot on blood samples, with power density of 796.17mW/cm2. The irradiation times were 1.8, 3.7and 6.2 secand so the different doses of irradiation 1.5,3 and 5 J/cm2, respectively.
Results: The erythrocyte sedimentation rate was measured after laser irradiation and compared with un-irradiated control sample. The results of this study showed thaterythrocyte sedimentation rate value increased significantly with a dose of 1.5J/cm² but not with the othertwo doses’ values in male persons but not in females. Moreover, the mean cell volume shows significant decrement post irradiation.
Conclusion: Laser irradiation induces physical changes in red blood cell membrane permeability and blood viscosity and consequently alters erythrocyte sedimentation rate.
Erythrocytes aggregation is an important physiological phenomenon in the circulation of blood, and is a basic characteristic of normal blood that plays a major role in cardiovascular system especially in the microcirculation. Blood samples have been taken from (30) volunteers (15 male, and 15 female), their ages (20-30) years. The Erythrocytes Sedimentation Rate (ESR) for those subjects was measured at different Packed Cells Volume (PCV) (10%-25%), and also it was measured at different temperature (10oC-25oC). The results show that there was a highly significant decrease (P<0.01) in ESR when the PCV increase and a highly significant increase (P<0.01) in ESR when the temperatures increase. The conclusion from these results is that the ESR va
... Show MoreBackground: The effect of Helium Neon laser (He-Ne 632.8 nm) was reported to protect cells from damage. We studied lymphocyte cells pre irradiated with (UVC 260 nm) to induce DNA damage. Investigations were carried using gel electrophoresis and test for cell viability. It has also been reported that effect depends on incubation period after damage. The extent of damage to the cells depends on the period of irradiation with UVC also on its intensity.
Objective: In this work we studied the effect of UVC on DNA damage and cell survival
Also study of the effect of He-Ne laser on cell survival after all being pre irradiated with UVC light and its protective effect on DNA post UV damage.
Method: This study was conducted in pathology d
Background: Ureteral stone can cause obstructive uropathy and subsequent deterioration of renal function. There are four treatment options for ureteral calculi: lithotripsy, ureteroscopy, laparoscopic ureterolithotomy, and open stone surgery. Holmium YAG laser is an excellent intracorporial lithotripter for all kinds of stones. Accordingly, there is steady increase in number of ureteroscopic laser lithotripsy operations in the managmant of Ureteral stone.
Objectives: this study was designed to demonstrate the effect of ureteric stone location on the success rate of ureteroscopic Holmium laser lithotripsy in the management of ureteric stones.
Patients and Methods: Ninety m
... Show MoreBackground: Low hemoglobin levels and lead exposure remain significant health issues in many parts of the world, often occurring together, however most of the researches concentrate on the effect of high levels of lead .This study aimed to demonstrate the effect of blood lead level on hemoglobin and packed cell volume (PCV).
Patients and Methods: Fifty eight adult volunteers were enrolled in this study with age range between 23 and 55 years, working in the different departments in medical college of Baghdad University. Whole blood was withdrawn in EDTA tubes. Hemoglobin and PCV were measured and blood lead level was estimated using blood lead testing system including lead care kit and lead care analyzer.
Results: After measuring bl
In the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in pot
... Show MoreThe present study was designed to investigate the effect of different concentrations of Maxxthor on some hematological and oxidative stress parameters in male albino rats.Twenty male rats with age of 6-8 weeks and weight of 200-250gm were equally divided into four groups as follow:G1 treated with normal saline as control group,while G2,G3andG4groups were treated with(0.01,0.1,1)mg\kg body weight of Maxxthor respectively for 40 days.The following hematological parameters were measured: red blood cell(RBC),hemoglobin (Hb),white blood cell(WBC), platelets(PLT),malondialdehyde(MDA),glutathione(GSH),catalase and vitamin E. The hematological parameters results revealed highly significant(p<0.01)decreasein RBC and H,while a highly significant(p<0.
... Show MoreZerumbone is a well-known compound having anti-cancer, anti-ulcer, anti-inflammatory and anti-hyperglycemic effects. During its use for the disease treatment, the membrane of erythrocyte can be affected by consumption of this bioactive compound. The current study was the first report of investigation of the hemolytic activities on human erythrocytes and cytotoxic profile of zerumbone. The toxicity of zerumbone on human erythrocytes was determined by in vitro hemolytic assay. Brine shrimp lethality assay was used to evaluate the cytotoxic effect of zerumbone at concentrations 10, 100 and 1000 μg/mL. The human erythrocyte test showed no significant toxicity at low concentrations, whereas hemolytic effect was amplified up to 17.5
... Show MoreThe effect of the aqueous extract of fig (Ficus carica) fruit was studied by using different concentrations of this fruit (15, 20 and 25 mg/kg of body weight) on some hematological parameters (hemoglobin concentration, packed cell volume, white blood cell count and platelets count) in female rabbits. Twenty female rabbits were randomly divided into four groups (five animals in each group). Three groups were dosed with the concentrations mentioned above, while the last was administered with distilled water and considered as control group. These animals were orally dosed by aqueous extract using a micropipette. The results showed that there was a significant (P<0.05) increase in hemoglobin concentration and packed cell volume means for all
... Show MoreAim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a
... Show MoreIn this study, Laser Shock Peening (LSP) effect on the polymeric composite materials has been investigated experimentally. Polymeric composite materials are widely used because they are easy to fabricate and have many attractive features. Unsaturated polyester resin as a matrix was selected and Aluminum powder with micro particles as a reinforcement material was used with different volume fraction (2.5%, 5% and 7.5%). Hand lay-up process was used for preparation the composites. Fatigue test with constant amplitude with stress ratio (R =-1) was carried out before and after LSP process with two levels of energy (1Joule and 2Joule). The result showed an increase in the endurance strength of 25.448% at 7.5% volume fraction when peened is 1J
... Show More