2D Electrical Resistivity has been applied at three selecting areas within the study area using Dipole-dipole and Wenner arrays with an a-spacing of 1 m, and the profile length was 120 m for both. The total data points were 4455 reads for Dipole-dipole, and the total data points for Wenner were 2340 reads, and the depth of each array was 15.4 m and 20.2 m, respectively. The 2D inverse results indicate the resistivity anomalies approximately at depth (2 - 7.8) m formed as a weakness zone lies within the quaternary and Injana Formation deposits and interbedded with secondary gypsum and gypcretes. Additionally, the inverse resistivity distribution model demonstrated that the area is impacted by groundwater that is interaction with sand, silt, and clay of the subsurface layers due to the gypsiferous and gypcrete deposits. They are distinguished by their ability to interact with water, whether it is surface or underground, and as a result, cause the emergence of a set of cavities and voids that may be filled with sediments that contain high levels of water and cause soil to wet. As well, the investigation gives the ideal array as Dipole-dipole rather than Wenner array due to its better in signal to noise ratio and provides the most suitable resolution for these applications, as well as the study, recommends conducting engineering and site investigations of the soil and determining the type of soil and the appropriate treatment methods that can overcome these problems.
The 2D resistivity imaging technique was applied in an engineering study for the investigation of subsurface weakness zones within University of Anbar, western Iraq. The survey was carried out using Dipole-dipole array with an n-factor of 6 and a-spacing values of 2 m and 5 m. The inverse models of the 2D electrical imaging clearly show the resistivity contrast between the anomalous parts of the weakness zones and the background resistivity distribution. The thickness and shape of the subsurface weakness zones were well defined from the 2D imaging using Dipole-dipole array of 2 m a-spacing. The thickness of the weakness zone ranges between 9.5 m to 11.5 m. Whereas the Dipole-dipole array with a-spacing of 5 m and n-factor of 6 allocated
... Show MoreThe 2D electrical resistivity imaging (ERI) is a non-destructive method with good efficiency to detect shallow subsurface features. The archeological subsurface features were investigated with this method in most cases with the assistance of other methods such as GPR method. Eleven 2D ERI profiles were carried out to investigate the subsurface archeological features in the Kish site in the Babylon area. The 2D electrical resistivity survey was achieved with ABEM Terrameter-LS2 Device and 30 electrodes with 1-meter spacing between the adjacent electrodes along each profile. The length of the profile is 29 meters and the spacing between the adjacent profiles is 3 meters. The software RES2DINV was used to obtain the final inverted
... Show MoreCracking of soils affects their geotechnical properties and behavior such as soil strength and stability. In this paper, 2D Electrical Resistivity Imaging Method, as a non-invasive technique, was adopted to investigate the effect of soil cracks of a centemetric scale on resistivity of sandy soil. The electrical resistivity measurements were carried out using ABEM SAS 300C Terrameter system at a laboratory scale using Wenner array. The measurements were interpreted using horizontal profiles, forward modeling and 2D inverse resistivity sections. The results showed that soil cracks cause significant changes in soil resistivity. These changes can be attributed to the high resistivity contrast between the highly resistive air-filled cracks an
... Show MoreThe friendly-environment geophysical methods are commonly used in various engineering and near-surface environmental investigations. Electrical Resistivity Imaging technique was used to investigate the subsurface rocks, sediments properties of a proposed industrial site to characterize the lateral and vertical lithological changes. via the electrical resistivity, to give an overview about the karst, weak and robust subsoil zones. Nineteen 2D ERI profiles using Wenner array with 2 m electrode spacing have been applied to investigate the specific industry area. One of these profiles has been conducted with one-meter electrode spacing. The surveyed profiles are divided into a number of blocks, each block consists of several parallel pr
... Show MoreThe current research demonstrates the ERI method's effectiveness as a supplementary engineering site investigation approach. Engineering site research is important to indicate the subsoil of proposed production sites. The benefit of the dipole-dipole array for ERI electrical resistivity imaging is that it provides informative records of subsurface geology and condition along with profiles. The dipole-dipole array was performed along with three parallel profiles at the Diyala University site to identify the buried facilities (pipes and cables) in the area. The buried electric cable embedded in a plastic tube was used for simulation to report and verify the field resistivity results. Interpretation of field facts confirmed that
... Show MoreIraqi western desert is characterized by a widespread karst phenomenon and caves. Euphrates formation (Lower Miocene) includes enormous sinkholes and cavities within carbonate rocks that usually cause severe damages to any kind of engineering facilities built over it. 3D resistivity imaging techniques were used in detecting this kind of cavities in complicated lithology. The 3D view was fulfilled by collating seven 2D imaging lines. The 2D imaging survey was carried out by Dipole-dipole array with (n) factor and electrode spacing (a) of 6 and 2m respectively. The horizontal slices of the 3D models give a good subsurface picture. There are many caves in all directions (x, y, z). They reveal many small caves near the surface. Thes
... Show MoreUnknown subsurface leaking water sources and possible subsurface seepage from a sewage tank in a garden at Al-Khawarizmi engineering college, University of Baghdad, were detected in this study. The 2D electrical resistivity imaging. The ERI survey is carried out along two lines, 60m and 50m long, with an electrode spacing of 1 m, forming a cross using the Wenner-Schlumberger array configuration. Line 1 is 60m, while line 2 is 50m. Soil samples were collected from line 1 at positions of electrode 34, which shows a high resistivity value, and electrode 55, which shows low resistivity, for laboratory analysis. Robust inversion and modelling processes showed relative change and high contrast in interpreted resistivities. Soil analy
... Show MoreAn oil spillage has been a great threat to human life in parts of Koya district, especially through the contamination of domestic water. An attempt was made to find and map the extent of pollution in the area. According to a field survey, more than 17 springs and 34 hand-dug and artesian wells have been contaminated with crude oil. The contamination was recorded recently after loading began of tens of oil tankers in the Taq-Taq oil field, and as a result hundred barrels of oil have spilled into the creeks and soil daily. Hence, 2D resistivity imaging was adopted via four laid-out traverses running normal to the strike of the outcrops. A Wenner-Schlumberger array configuration was used to achieve both vertical and lateral resistivity dist
... Show MoreIn this study, the four tests employed for non-linear dependence which is Engle (1982), McLeod &Li (1983), Tsay (1986), and Hinich & Patterson (1995). To test the null hypothesis that the time series is a serially independent and identical distribution process .The linear structure is removed from the data which is represent the sales of State Company for Electrical Industries, through a pre-whitening model, AR (p) model .From The results for tests to the data is not so clear.
The 2D imaging survey was conducted across an unknown K- 3 cavity that is located in Haditha area-Western Iraq.2D measurements are collected along two intercrossing traverses above the cavity with 105m length of each one. Dipole-dipole array is performed with n-factor of 6 and a-spacing equals to 5m. The inverse models of 2D imaging technique showed clearly that the resistivity contrast between the anomalous part of cavity and background resistivity of rocks is about 800:100 Ωm .In addition, the invers models showed that the depth from ground surface to the upper roof of cavity approximately equals to 11m near the cavity operator. So, the K-3 cavity is well defined from 2D imaging with Dipole –dipole array in comparison with the actua
... Show More