Preferred Language
Articles
/
ijs-7629
Townsend Discharge and Streamer Breakdown within Sphere-Air-Sphere Configuration
...Show More Authors

     The main aim of the present paper is to study the electric breakdown in a uniform electric discharge system. The system consists of two spheres separated by a dielectric. The dielectric is dry air. Certain boundary conditions are taken into consideration as applied voltage, pressure, and domain. The formation of discharge types as Townsend and streamer under different distance gaps (1, 0.9,0.8, 0.6, 0.4, 0.2, 0.1) mm was sudied. The temperature effect on the breakdown voltages for the discharge process is also included. Seven different temperature steps are chosen in the study.  Comsol Multiphysics software is used for the simulation model as a plasma model. Results show that as the gap distance increases the breakdown voltage increases for each of the discharges. For maximum electric field, as the distance increases the field also increases. For gap distance, the temperature effects are more apparent at the higher values of the pressure.  The maximum electric field increases as the voltage increases with the temperature.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
The Streamer Discharge Propagation Within Normal Hexane and Acetone Liquids
...Show More Authors

Based on the streamer growth model, the streamer discharge propagation was simulated in aid of finite element technique. That was done within two non- mixed dielectric liquids (Normal-Hexane and Acetone) located between two electrodes in pin - plane configuration. The output results show that, the path of the streamer was affected by the interface between the two liquids; the streamer path crosses this interface under some conditions such as the permittivity of the liquids and the distance between this interface and the tip of the pin. Under other conditions, the streamer path grows along the interface. The results were assisted by the development of the potential and the electric field distributions with the growth of the streamer propa

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 30 2023
Journal Name
Iraqi Journal Of Science
The Numerical Analysis for Electrical Streamer Discharge Behaviour in Transformer Oil
...Show More Authors

      In this paper, a numerical analysis was carried out using finite element method to analyse the mechanisms for streamer discharges. The hydrodynamic model was used with three charge carriers equations (positive ion, negative ion and electron) coupled with Poisson equation to simulate the dynamic of streamer discharge formation and propagation. The model was tested within a 2D axisymmetric tip-plate electrodes configuration using the transformer oil as the dielectric liquid. The distance between the electrodes was fixed at 1 mm and the applied voltage was 130 kV at 46 ns rising time. Simulation results showed that the time has a clear effect on the streamer propagation along the symmetry axis. In addition, it was observed that t

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 30 2024
Journal Name
Iraqi Journal Of Science
Numerical Analysis for Streamer Discharge at the Discharge Transition from the Second to the Third Mode in Transformers Oil
...Show More Authors

     This study is a numerical analysis of the transition process from the second to the third mode in transformer oil. In this study, it was determined how to change from the second to the third mode, which is thought to be a precursor to the process of electrical breakdown, which results in a significant loss of electrical energy and harm to electrical devices and equipment. The initiation time, length, rate of propagation velocity, and radius of the streamer discharge were determined. The transition from the second to the third mode during the electrical discharge process may lead to the occurrence of an electrical breakdown, which is one of the greatest challenges facing scientists and engineers who deal with the

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Engineering
Influence of Fire-Flame Duration and Temperature on the Behavior of Reinforced Concrete Beam Containing Water Absorption Polymer Sphere; Numerical Investigation
...Show More Authors

One of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model at elevated t

... Show More
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Engineering
Influence of Fire-Flame Duration and Temperature on the Behavior of Reinforced Concrete Beam Containing Water Absorption Polymer Sphere; Numerical Investigation
...Show More Authors

One of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model at elevated t

... Show More
Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Engineering
Influence of Fire-Flame Duration and Temperature on the Behavior of Reinforced Concrete Beam Containing Water Absorption Polymer Sphere; Numerical Investigation
...Show More Authors

One of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model a

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Science
The Effect of Axial Magnetic Field on The Breakdown Voltage of Air at Low Pressure
...Show More Authors

To add more details about the effect of the axial magnetic field on the plasma profile, the breakdown voltage of air was investigated at low pressure (9-15 Pa) in the presence of axial magnetic field (0.01-0.04T). The air was ignited by a DC voltage between two plain electrodes of aluminum separated by a distance (8.5cm). The measurements showed that the discharge voltage decreases to a minimum value, then returns to increase over the minimum with increasing the magnetic field strength, at all pressures in the range. It was also observed that a maximum decrease in the discharge voltage is obtained near the minimum of  Paschen curve from the right side. The decrease in the discharge voltage was caused mainly by the effect of magnetic

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Negative Streamer Propagation in Nitrogen
...Show More Authors

       For the development of negative streamer, a one dimension simulation is presented when a negative electric field is applied at atmospheric pressure to a 4 mm gap in nitrogen. At applied electric fields of 55, 60, 65 and 70 kV/cm, streamer parameters were studied at various time intervals. The aim of this paper is to determine the minimum electric field that must be applied for stable propagation of negative streamer discharge in nitrogen gas. As functions of position and time, the calculations provide detailed electron and ion density predictions, electric fields and density of space charges. The time interval was with a nanosecond resolution. Using 8000 element mesh to resolve the characteristics of the streamer, spatial re

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 29 2019
Journal Name
Iraqi Journal Of Science
Effect of Temperature on the Working Parameters of Negative Corona Discharge with Coaxial Electrodes Configuration
...Show More Authors

     The influence of ambient temperature on the various parameters of negative corona discharge in atmospheric dry air with coaxial cylindrical electrodes is investigated. The calculations are achieved using the finite element method by COMSOL Multiphysics software. The investigation aims to notice the effect many of working temperatures on the I-V characteristic curve of negative corona discharge in the air. The calculations of several parameters (electron density, temperature, ...) are presented visually and discussed. The results of the work are compared with theoretical and experimental data and they are in a good agreement.

View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref