In the present work, the possibility of treating many types of radioactive sources was examined practically. Six types of sealed radioactive sources were selected: 137Cs, 133Ba, 90Sr, 152Eu, 226Ra, and 241Am. The sources were exposed to a neutron flux emitted from 241Am/Be source for 33 days. The results showed a measurable reduction of activity for 226Ra, 241Am, and 152Eu, while the other radionuclides, 137Cs, 133Ba, and 90Sr, showed less response to neutron incineration.