This study aims to provide verification between measured and calculated radiation dose using three different ionization chamber detectors in Grid plans to select the best ones To the best of our knowledge, this is the first practical experiment in such subject. Grid radiotherapy is an unconventional method for bulky tumors treatment. It is characterized by a single-fraction and high radiation dose. Ten cases (scenarios) were selected to achieve Grid plans by MLCs, with a single dose of 1500-2000 cGy. Three ionization detectors were employed to measure the maximum, mean, and point doses (cGy), and match them with those calculated by the linear accelerator used in this study. The results showed significant differences among the three detectors in measuring the maximum and mean doses, with p-value = 0.0016 and 0.06, respectively. While the differences among the measured three detectors and calculated doses for the point dose were non-significant, p = 0.12. The variation in the results of the corresponding percentage between calculated and measured doses depended on the type and position of the detector, the scattering, and the leakage of the radiation. In conclusions, the Semi-flex chamber gives the best results.
Radiation measuring devices need to process calibration which
lose their sensitivity and the extent of the response and the amount of
stability under a changing conditions from time to time and this
period depends on the nature and use of field in which used devices.
A comparison study was done to a (451P) (ionization chamber
survey meter) and this showed the variation of calibration factor in
five different years. This study also displayed the concept of
radiation instrument calibration and necessity of every year
calibration of them.
In this project we used the five years calibration data for ionization
chamber survey meter model Inspector (451P) to get that the values
of Calibration Factor (CF) and Res
The fact that the signature is widely used as a means of personal verification
emphasizes the need for an automatic verification system. Verification can be
performed either Offline or Online based on the application. Offline systems work on
the scanned image of a signature. In this paper an Offline Verification of handwritten
signatures which use set of simple shape based geometric features. The features used
are Mean, Occupancy Ratio, Normalized Area, Center of Gravity, Pixel density,
Standard Deviation and the Density Ratio. Before extracting the features,
preprocessing of a scanned image is necessary to isolate the signature part and to
remove any spurious noise present. Features Extracted for whole signature
Breast cancer (BC) is first of the top 10 malignancies in Iraq. Dose‐volume histograms (DVHs) are most commonly used as a plan evaluation tool. This study aimed to assess DVH statistics using three‐dimensional conformal radiotherapies in BC in an adjuvant setting.
A retrospective study of 70 histologically confirmed women diagnosed with BC was reviewed. The study was conducted between November 2020 and May 2021, planning for treatment with adjuvant three‐dimensional conformal radiotherapies. The treatment plan used for each woman was based on an analysis of the volumetric dose, inclu
A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreUranium concentration was estimated in urine samples of three age groups, G1≤ 30 years, n=28, G2 age range of 31-40 years, n=28, and G3 of age > 40 years, n=32, using two types of detectors CR-39 and LR-115 solid-state nuclear track detector (SSNTD) for results comparison.
Results showed that uranium mean level values for CR-39 were 1.961 ±0.08 µg/L, 1.810 ±0.09 µg/L and 1.814 ±0.076 µg/L for G1, G2 and G3 respectively, while the mean values of uranium concentration using LR-115 were 0.972 ±0.07 µg/L, 0.922 ±0.07 µg/L and 1.018 ±0.08 µg/L in G1, G2 and G3 respectively, with significant statistical difference betw
... Show MoreThe method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.
In this work , a hybrid scheme tor Arabic speech for the recognition
of the speaker verification is presented . The scheme is hybrid as utilizes the traditional digi tal signal processi ng and neural network . Kohonen neural network has been used as a recognizer tor speaker verification after extract spectral features from an acoustic signal by Fast Fourier Transformation Algorithm(FFT) .
The system was im plemented using a PENTIUM processor , I000
MHZ compatible and MS-dos 6.2 .
In this research, a mathematical model of tumor treatment by radiotherapy is studied and a new modification for the model is proposed as well as introducing the check for the suggested modification. Also the stability of the modified model is analyzed in the last section.
Offline handwritten signature is a type of behavioral biometric-based on an image. Its problem is the accuracy of the verification because once an individual signs, he/she seldom signs the same signature. This is referred to as intra-user variability. This research aims to improve the recognition accuracy of the offline signature. The proposed method is presented by using both signature length normalization and histogram orientation gradient (HOG) for the reason of accuracy improving. In terms of verification, a deep-learning technique using a convolution neural network (CNN) is exploited for building the reference model for a future prediction. Experiments are conducted by utilizing 4,000 genuine as well as 2,000 skilled forged signatu
... Show More