Preferred Language
Articles
/
ijs-3697
Spectroscopic Diagnosis of the CdO:CoO Plasma Produced by Nd:YAG Laser
...Show More Authors

      In this paper, the optical emission spectrum (OES) technique was used to analyze the spectrum resulting from the (CdO:CoO)  plasma in air, produced by Nd:YAG laser with λ=1064 nm, τ=10 ns, a focal length of 10 cm, and a range of energy of 200-500 mJ. We identified laser-induced plasma parameters such as electron temperature (Te) using Boltzmann plot method, density of electron (ne), length of Debye (λD), frequency of plasma (fp), and number of Debye (ND), using two-Line-Ratio method. At a mixing ratio of X= 0.5, the (CdO:CoO) plasma spectrum was recorded for different energies. The results of plasma parameters caused by laser showed that, with the increase in laser energy, the values of Te, ne and fp were increased, while the value of λD was decreased. The calculated electron temperature value was in the range of 0.449-0.619 eV at ratio X=0.5

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of CdO1-X: SnX Plasma Produced by Nd:YAG Laser
...Show More Authors

In this work, the optical emission spectrum technique was used to analyze the spectrum resulting from the CdO:Sn plasma produced by laser Nd:YAG with a wavelength of (1064) nm, duration of (9) ns, and a focal length of (10) cm in the range of energy of 500-800 mJ. The electron temperature (Te) was calculated using the in ratio line intensities method, while the electron density (ne) was calculated using Saha-Boltzmann equation. Also, other plasma parameters were calculated, such as plasma (fp), Debye length (λD) and Debye number (ND). At mixing ratios of X=0.1, 0.3 and 0.5, the CdO1-X :SnX plasma spectrum was recorded for different energies. The change

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (10)
Scopus Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition
...Show More Authors

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for SnO2 doped ZnO prepared by pulse Nd:YAG laser deposition
...Show More Authors

 In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located  that  The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.

View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Spectroscopic Diagnosis of Cobalt Plasma Produced by OES Technique and Influence of Applied Voltage on Plasma Parameters
...Show More Authors

     In this work, plasma system that operates at vacuum was designed and built using a sheet of cobalt metal for the purpose of diagnosing plasma and measuring its parameters, as it is very important to know the processes that accompany plasma generation and are closely related to them, including the electron density in the plasma and its temperature. The spectroscopic diagnosis was done by optical emission spectroscopy (OES) which relies on the calculation of the optical radiation emitted by the plasma to describe plasma parameters in the chemical, molecular, and ionic radiator's near environment, and applied to cobalt metal at vacuum D.C high voltage power supply. The results showed the rise of spectral lines intensity with increa

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Plasma characteristics of Ag:Al alloy produced by fundamental and second harmonic frequencies of Nd:YAG laser
...Show More Authors

In this work, the spectra for plasma glow produced by pulse
Nd:YAG laser (λ=532 and 1064nm) on Ag:Al alloy with same molar
ratio samples in distilled water were analyzed by studying the atomic
lines compared with aluminum and silver strong standard lines. The
effect of laser energies of the range 300 to 800 mJ on spectral lines,
produced by laser ablation, were investigated using optical
spectroscopy. The electron temperature was found to be increased
from 1.698 to 1.899 eV, while the electron density decreased from
2.247×1015 to 5.08×1014 cm-3 with increasing laser energy from 300
to 800 mJ with wavelength of 1064 nm. The values of electron
temperature using second harmonic frequency are greater than of<

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma
...Show More Authors

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 26 2022
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of CdO: Fe Plasma Generated by Nd: YAG Laser
...Show More Authors

     In this work, the optical emission spectrum technique was used to analyze the optical emission spectrum of (CdO: Fe) plasma produced by laser Nd: YAG with a wavelength of (532) nm, a period of 10 ns, and a focal length of 10 cm in the energy range of (200-500) mJ. The electron temperature (Te) was determined using the method of line intensities ratio. Using the Saha-Boltzmann equation, the electron density (ne) was determined. Other plasma parameters such as plasma frequency (fp), Debye length (λD) and Debye number (ND) were also measured. The CdO: Fe (at a mixing ratio of X= 0.5.) plasma spectrum was observed for different energies. As a fu

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (13)
Scopus Crossref
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Spectroscopic study of AL nitrogen plasma produced by DC glow discharge
...Show More Authors

The work done in this paper to study properties for nitrogen plasma generated by method electrical discharge when the aluminum was a target. Experimental study on the effect electrodes material, applied voltages on spectroscopic parameter for DC discharge plasma in Nitrogen gas using planner electrodes were done.

     The electron temperature, increase with increasing applied voltage from (700 to 1100) V. While the plasma density, calculate by Stark broadening effect, which increase with it.

     The peaks intensities for N2 transition (λ= 336.6 nm and 391.4 nm) increase with increasing applied voltage. The vibrational energy (TVib) for N2 molecular increase from 0.165 to 0.185 eV

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 30 2022
Journal Name
Iraqi Journal Of Science
Measurements and Calculations of parametrs of Zinc Oxide Plasma Produced by Laser induced Breakdown Spectroscopy
...Show More Authors

          In this work, the optical emission characteristics of the ZnO plasma were presented. The plasma parameters: electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD) were  studied with  a spectrometer that collects the spectrum ZnO plasma in air produced by Nd:YAG laser,(λ=1064 nm) at ratio X=0.5 in the range of energy of (700-1000 mJ), duration (10 ns). The Boltzmann plot methodwas employed to calculate the electron temperature (Te), while the Stark broadening  was used to determine the electron density (ne), Debye duration (λD), and plasma frequency (fp).  Te, ne, and fp

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic Diagnostic of Cadmium Sulfide Plasma Produced By LIBS
...Show More Authors

Abstract

       The current study was carried out to reveal the plasma parameters such as ,the electron temperature ( ), electron density (ne) , plasma frequency (fp), Debye length ( ) , Debye number (   for  CdS to employ the LIBS for the purpose of analyzing and determining spectral emission lines using . The results of electron temperature for CdS range (0.746-0.856) eV , the electron density(3.909-4.691)×1018 cm-3. Finally ,we discuss plasma parameters of CdS  through  nano second  laser generated plasma .

View Publication Preview PDF
Crossref (1)
Crossref