Preferred Language
Articles
/
ijs-3493
Influence of Non-Thermal Plasma (DBD) On Infertility Male Semen with Low Sperm Motility and Dna Damage

Non-thermal plasma(Dielectric barrier discharge) has many uses including living tissue sterilization, inactivation of the bacteria, excimer formation, angiogenesis, and surface treatment. This research aim is to use cold plasma as a tool to search the effect of the dielectric barrier discharge system at room temperature on human sperm motility and DNA integrity. This work was performed on 60 human semen samples suffering from low motility; each sample was prepared by centrifugation method, then each semen sample was divided into two sections, the first section is before significant exposure to the plasma system (DBD) and the second section is after treatment with the DBD system at ambient temperature. Before and after exposure to non-thermal Plasma (DBD), DNA integrity and sperm motility were assessed, patients suffered from asthenospermia has a high level of DNA fragmentation than fertile male, ( 24.16±4.14) p<0.001 for untreated and after treatment the semen slide with dielectric barrier discharge the percentage decreases to (9.16±1.76) p>0.006, and the comet slide was (35.44±4.15) then the percentage decline to (19.86 ±2.44) these results have shown that cold plasma improves sperm motility and decreases from DNA damage in patients with medium and high level of DNA damage.  

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 02 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Effect of Swim Up Techniques on Sperm Motility and DNA Integrity Versus Unprepared Semen

Background: The need for assisted reproduction technologies (ART) for the establishment of pregnancies has steadily increased worldwide. Therefore, it is of vital importance that an efficient sperm preparation technique used for retrieval of high-quality spermatozoa contributes to the creations of high-quality embryos, with high implantation potential.
Objective: to study the effect of swim up technique on human sperm motility and DNA integrity.
Subject and methods: A prospective study carried on 70 samples of human semen; each sample, divided into 2 parts, one part was prepared by swim-up technique and the other not, and then study sperm motility and DNA integrity in both parts. Sperm DNA integrity was determined using a modified

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effects of Licorice Extract on Sperm Motility of Chilled Stored Ram Semen

  This study was designed to investigate the effects of licorice extract (Glycyrrhiza glabra L.) addition to semen diluters on ram sperm progressive motility during storage at 5 ËšC for 72 h. Semen was collected from 3 proven Awassi rams. Licorice extract powder was added at levels of 1, 5, 10, 50 and 100 µg per ml. of diluter. Diluter containing no licorice extracts served as control (0).Progressive motility was estimated subjectively after dilution (0h), and at 24, 48, and 72 h of storage. The experiment was replicated 2 times with egg yolk-tris (EYT) diluter and 2 times with yolk- glucose-citrate diluter. Progressive motility increased significantly (p < 0.01) in levels of licorice extract 1, 5, 10, 50 and 100 µg / ml

... Show More
View Publication Preview PDF
Publication Date
Fri May 14 2021
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Semen Analysis and Insight into Male Infertility

Objectives: Semen analysis is the cornerstone for the valuation of the male partner in the infertile couples. This test has been standardized throughout the world through the World Health Organization (WHO) since the1970s by producing, editing, updating, and disseminating a semen analysis manual and guidelines. A retrospective study to give an insight about  male infertility. Methods: This retrospective study assessed the semen findings of 1000 men evaluated at the  Department of Urology, Al-Kindy Teaching Hospital in Baghdad-Iraq  between January 2016 and May 2019. Semen analysis were done for them. Results: According to WHO standard for semen normality, 1000 samples that were analyzed, normospermia was shown in 835 (83.5%)males

... Show More
Scopus (2)
Crossref (2)
Scopus Crossref
View Publication
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Laser Biostimulation Effect on Human Sperm Motility

Background: Sperm motility disorder is an important cause of infertility in male, and one of the causes of reduced motility of the sperm is the disorders of the mitochondria because it provides the required energy for sperm motility, Laser biostimulation or low-level laser therapy has a positive effect on the mitochondria and led to increasing the synthesis of ATP. Method: Twenty fresh human semen samples were used in this research study, each sample was separated into two portions, one was used as control which is not exposed to the laser beam and the other was irradiated with the wavelength of 410 nm diode laser with an output power of 100 mW and an exposure time of 60 seconds, then the measurement of

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of non-thermal plasma by FE-DBD scheme on lipids in blood in vivo study

This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.

Scopus Crossref
View Publication
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Influence of Dielectric Media on the Plasma Characteristics in DBD Discharge

    The study of the surface plasma characteristics under atmospheric pressure is a new branch and tool in physics. Building generation dielectric barrier discharge (DBD) system at atmospheric pressure and studying its thermal characterizations. The discharge was produced by applying a high voltage of 20 kV with a frequency of 8 kHz. The thermal characterization was done by measuring discharge temperature for different horizontal surface areas and different types of insulating material. The results indicated that the effect of the area and the type of insulator affect the discharge (increasing or decreasing) according to the operation conditions because they affect, as expected, the DBD . The plasma temperature increased with the decr

... Show More
Scopus (3)
Scopus Crossref
View Publication Preview PDF
Publication Date
Wed Nov 30 2022
Journal Name
Iraqi Journal Of Science
Influence of Distance and Argon Flow rate on Pseudomonas aeruginosa Bacteria Exposed to Non thermal Plasma at Atmospheric Pressure

     In this research, a type of gram negative bacteria was exposed to non-thermal plasma at a distance of (2 and 3 cm) from the plasma flow nozzle, with the use of an alternating power supply (5KHz), where exposure was made at two different voltages (4.9 and 8 kV). A negative gram of Pseudomonas aeruginosa bacteria was isolated and exposed to non-thermal plasma at different flow rates of argon gas whose value ranged from (1-5) liters/minute. The results showed that bacterial killing rate is directly proportional to distance while exposing the samples to non-thermal plasma, and the best factors by which a complete killing rate was obtained were at a distance of 2 cm with a voltage of 8 kV and a gas flow rate of 5 liters/min,

... Show More
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Oct 02 2005
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Crossref
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
Crossref (1)
Crossref
View Publication Preview PDF