A Monte Carlo simulation has been used to design program which simulate gamma rays backscattering system. Gamma ray backscattering is very important to get useful information about shielding, absorption and counting problems. Simulation was done of a 661.6 KeV from a collimated point source of 137Cs. When increasing the scattering angle of photon which emerging from Iron target , as the incident gamma beam angles of 15°, 45° and 75°, the results showed that the single scattering count decreases. Whereas, this count increased by increasing the incident angle. In addition, the single scattering peak (count) increases according to the sample thickness until „saturation thickness‟. Our simulation results are useful to evaluate the optimal configuration of systems using Compton backscattered radiation and to access the feasibility for setting up experimentally this system. Also, it will be used to determine the best conditions under which this method can be applied to testing electron densities or to assess the thickness of sample to locate defects in them.
The primary focus of the study factor reverse polymerization styrene polymer kinetics and distribution weight Aljaia in Blma Aldhur free reverse The study was conducted wi Mamahakah and using the Monte Carlo method
This Research deals with estimation the reliability function for two-parameters Exponential distribution, using different estimation methods ; Maximum likelihood, Median-First Order Statistics, Ridge Regression, Modified Thompson-Type Shrinkage and Single Stage Shrinkage methods. Comparisons among the estimators were made using Monte Carlo Simulation based on statistical indicter mean squared error (MSE) conclude that the shrinkage method perform better than the other methods
This paper presents the first data for bremsstrahlung buildup factor (BBUF) produced by the complete absorption of Y-91 beta particles in different materials via the Monte Carlo simulation method. The bremsstrahlung buildup factors were computed for different thicknesses of water, concrete, aluminum, tin and lead. A single relation between the bremsstrahlung buildup factor BBUF with both the atomic number Z and thickness X of the shielding material has been suggested.
The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.
Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In
... Show MoreThis research aims to predict the value of the maximum daily loss that the fixed-return securities portfolio may suffer in Qatar National Bank - Syria, and for this purpose data were collected for risk factors that affect the value of the portfolio represented by the time structure of interest rates in the United States of America over the extended period Between 2017 and 2018, in addition to data related to the composition of the bonds portfolio of Qatar National Bank of Syria in 2017, And then employing Monte Carlo simulation models to predict the maximum loss that may be exposed to this portfolio in the future. The results of the Monte Carlo simulation showed the possibility of decreasing the value at risk in the future due to the dec
... Show MoreIn this article, a numerical method integrated with statistical data simulation technique is introduced to solve a nonlinear system of ordinary differential equations with multiple random variable coefficients. The utilization of Monte Carlo simulation with central divided difference formula of finite difference (FD) method is repeated n times to simulate values of the variable coefficients as random sampling instead being limited as real values with respect to time. The mean of the n final solutions via this integrated technique, named in short as mean Monte Carlo finite difference (MMCFD) method, represents the final solution of the system. This method is proposed for the first time to calculate the numerical solution obtained fo
... Show MoreThis research aims to identify the means and forms of interactive communication concerning Iraqi topics on the websites of global radio stations, namely Sawa and Monte Carlo. It also seeks to uncover the editorial and artistic interactions related to Iraqi topics on the selected websites chosen as the research sample, comparing them with the editorial interaction within the Iraqi context between the Radio Monte Carlo and Sawa websites.
The research yields several conclusions, including the following:
Iraqis focus their interaction with topics related to Iraq on Facebook for both Radio Monte Carlo and Sawa; Arabs show higher levels of interaction on Twitter with Radio Monte Carlo; Participants on the webs
A program using Mont Carlo techniques has been written to calculate the effective solid angle of the detection system and simulate the response of the HPGe to mono-energetic protons from an extend source. It has been found that the fraction of the protons which leave through the cylindrical surface and deposit only part of their kinetic energy in the crystal increases with proton energy and the consequent increase in their range.
A non-destructive assay (NDA) for radioactive waste drum has been studied
using a local manufacturing gamma scanning system. The gamma system has been
designed and implemented using scanning system contains a high efficiency
portable HPGe detector for characterization and surveying the radioactive waste
drums at Al-Tuwaitha site- Baghdad. To achieve identification with nonhomogenous
radioactive waste drum, six parallel plastic pipes (2cm in diameter)
were inserted inside the cement type Portland contain radioactive sources and
located at different distances from the outer diameter of the drum. The efficiency
calibration is measured by conventional technique, using five miscellaneous radio
nuclides with drum. Th