Preferred Language
Articles
/
ijl-108
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitation wavelength (λexcit.) = 669 nm). Five teeth were sent to
histopathological examination to confirm the efficacy of laser fluorescence technique for the
determination of actual carious lesion depth. The results are leading to the detection of carious lesions for
different depths. The deepest carious lesions revealed high fluorescence intensity. Based on these
findings; it was concluded that 650 nm CW diode laser (λexcit. = 669 nm 40 mW) is a suitable and a
reliable tool for caries diagnosis and depth assessment. Histopathological findings for the estimation of
actual carious lesion depth revealed a good correlation with that of laser fluorescence technique.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 14 2018
Journal Name
Fiber And Integrated Optics
Design Investigation of 2 × 2 Mach–Zehnder Optical Switch Based on a Metal–Polymer–Silicon Hybrid Plasmonic Waveguide
...Show More Authors

In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Certain Assessment of Using MWCNT Nps in Drilling Fluid to Mitigate Stick-Slip Problem during Drilling Operation System
...Show More Authors

   Stick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.

   Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.

   Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Test the Cytotoxicity of Pleurotin Extracted from an Edible Mushroom Pleurotus osteratus Against Three Human Carcinoma Cell Line
...Show More Authors

The study included selection six species of the fungi related to Pleurotus genus were evaluated for their ability to production of Pleurotin, one of them, Pleurotus ostreatus (P.11) was isolated and identified in the present study. Pleurotin was extracted with screening by Thin Layer Chromatography (TLC) and quantification High Performance Liquid Chromatography (HPLC). Cytotoxicity of Pleurotin extracted from P. ostreatus (P.11) grown in different sugar sources (galactose, mannitol, sucrose, dextrose and lactose) liquid media was test against three selected cancer cell lines, CaSki, MCF-7 and A549 addition to Human Non Cancer Fibroblast Cell Line (MRC-5). Pleurotin of P. ostreatus (P.11) grown in galactose induced the significant highest

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Synthesis of New Heterocyclic Derivatives from 4-(3, 5-Dimethyl-1-phenyl-1H-pyrazol-4-ylazo)- benzoic acid
...Show More Authors

In this work pyrazolin derivatives were prepared from the diazonium chloride salt of 4-aminobenzoic acid. Azo compounds were prepared from the reaction of an ethanolic solution of sodium acetate and calculated amount of active methylene compound namely, acetyl acetone to obtain the corresponding hydrazono derivative (1). Cyclocondensation reaction of compounds (1) with hydrazine hydrate and phenyl hydrazine in boiling ethanol affording the corresponding pyrazoline-5-one derivatives of 4-aminobenzoic acid (2,3). Then compound (3) was reacted with thionyl chloride to give the corresponding acid chloride derivative(4), followed by conversion into the corresponding acid hydrazide derivative (5) carboxylic acid thiosemicarbazide (11), esters

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 29 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The static aging effect on the seedless synthesis of different ranges FAU-type zeolite Y at various factors
...Show More Authors

This work investigates generating of pure phase Faujasite-type zeolite Y at the ranges chosen for this study via a static aging step in the absence of seeds synthesis. Nano-sized crystals may result when LUDOX AS-40 is used as a silica source for gel composition of range 6 and the crystallization step may be conducted for a period of 4 to 19 hr at 100 ⁰C. Moreover, large-crystals with high crystallinity pure phase Y zeolite can be obtained at hereinabove conditions but when hydrous sodium metasilicate is used as a silica source. The other selected ranges also offer pure phase Y zeolite at the same controlled conditions.

Crossref (13)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Marine And Petroleum Geology
Geophysical evidence for structurally-controlled, authigenic carbonate cementation in the Laminaria High, Bonaparte basin, Northwest Shelf of Australia
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Terramechanics
Interaction of a rigid beam resting on a strong granular layer overlying weak granular soil: Multi-methodological investigations
...Show More Authors

In the geotechnical and terramechanical engineering applications, precise understandings are yet to be established on the off-road structures interacting with complex soil profiles. Several theoretical and experimental approaches have been used to measure the ultimate bearing capacity of the layered soil, but with a significant level of differences depending on the failure mechanisms assumed. Furthermore, local displacement fields in layered soils are not yet studied well. Here, the bearing capacity of a dense sand layer overlying loose sand beneath a rigid beam is studied under the plain-strain condition. The study employs using digital particle image velocimetry (DPIV) and finite element method (FEM) simulations. In the FEM, an experiment

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Journal Of Radioanalytical And Nuclear Chemistry
Prostate tumor therapy advances in nuclear medicine: green nanotechnology toward the design of tumor specific radioactive gold nanoparticles
...Show More Authors

We report herein an innovative approach to prostate tumor therapy using tumor specific radioactive gold nanoparticles (198Au) functionalized with Mangiferin (MGF). Production and full characterization of MGF-198AuNPs are described. In vivo therapeutic efficacy of MGF-198AuNPs, through intratumoral delivery, in SCID mice bearing prostate tumor xenografts are described. Singular doses of the nano-radiopharmaceutical (MGF-198AuNPs) resulted in over 85% reduction of tumor volume as compared to untreated control groups. The excellent anti-tumor efficacy of MGF-198AuNPs are attributed to the retention of over 90% of the injected dose within tumors for long periods of time. The retention of MGF-198AuNPs is also rationalized in terms of the higher

... Show More
View Publication
Scopus (38)
Crossref (38)
Scopus Clarivate Crossref
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
Slump Test versus Straight Leg Raise Test in the Diagnosing of Lumbar Disc Herniation: A Prospective Comparative Study
...Show More Authors

Background: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients

... Show More
Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
An Instruction Program for Residents of Geriatric-Care Homes about Personal Hygiene in Al Cyelakh Geriatric Care Home
...Show More Authors

Objective(s):        The study aims to evaluate the information of the elderly about personal hygiene , and to find out the relationship between residents of geriatric-care homes knowledge and their demographic characteristics .

Methodology:      A quasi-experimental design study is conducted at geriatric home  in Al Cyelakh  Geriatric Care Home. The study was started at between November 20, 2021, and March 1, 2023. randomly sample of (30) elderly  in geriatric home were studied . Data were collected throughout the utilization of the adopted questionnaire and interview technique. The questionnaire was consists of (40) items related to concerned personal hygiene geriatrics persons, t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref