The petroleum industry, which is one of the pillars of the national economy, has the potential to generate vast wealth and employment possibilities. The transportation of petroleum products is complicated and changeable because of the hazards caused by the corrosion consequences. Hazardous chemical leaks caused by natural disasters may harm the environment, resulting in significant economic losses. It significantly threatens the aim for sustainable development. When a result, determining the likelihood of leakage and the potential for environmental harm, it becomes a top priority for decision-makers as they develop maintenance plans. This study aims to provide an in-depth understanding of the risks associated with oil and gas pipelines. It also tries to identify essential risk factors in flowline projects, as well as their likelihood and severity, in order to reduce loss of life and increased expenditures as a result of safety issues. The monetary quantification was used to determine the leakage-induced environmental losses. Using a 5-by-5 probability-currency matrix, the level of environmental risk was evaluated the safety and risk-based inspection (RBI) is evaluated through the use of specific schedules to determine the likelihood of failure (LOF) and Consequence of Failure (COF). The risk level appears in the matrix, and appropriate maintenance steps should be taken to reduce risks, such as injecting corrosion inhibitors to protect the Pipelines, activating cathodic protection or coating. Overall, this research contributes to the prevention of petroleum product leakage due to the corrosion consequences in the transportation sector. Also, encourage non-environmental risk decision-makers to gain a better understanding of the risk level.
The risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate
... Show MoreAlongside the development of high-speed rail, rail flaw detection is of great importance to ensure railway safety, especially for improving the speed and load of the train. Several conventional inspection methods such as visual, acoustic, and electromagnetic inspection have been introduced in the past. However, these methods have several challenges in terms of detection speed and accuracy. Combined inspection methods have emerged as a promising approach to overcome these limitations. Nondestructive testing (NDT) techniques in conjunction with artificial intelligence approaches have tremendous potential and viability because it is highly possible to improve the detection accuracy which has been proven in various conventional nondestr
... Show MoreConcentration of NORM then radiological hazard indices were investigated and assessed in different stages of oil and gas production industry that belongs to East Baghdad Oil Field. Sixteen samples of different types of materials were collected representing oil and gas production from first stage to final stage. The samples are prepared then sent to Radiation Protection Center (RPC) / Ministry of Environment for radioactivity analysis using gamma ray spectrometry system based on HPGe. The results show that max value of Ra-226 is 252.4 Bq/kg in sediment sample collected from the final stage of water treatment before it is transferred to disposal well and min value is 1.2 Bq/kg in formation water. The max. activity of Th-232 is 79.4Bq/kg al
... Show More
The prevalence of gastrointestinal symptoms of COVID-19 is variable with different types of presentations. Some of them many present with manifestations mimicking surgical emergencies. Yet, the pathophysiology of acute abdomen in the context of COVID-19 remains unclear. We present a case of a previously healthy child who presented with acute appendicitis with multisystemic inflammatory syndrome. We also highlight the necessity of considering the gastrointestinal symptoms of COVID-19 infection in pediatric patients in order to avoid misdiagnosis and further complications. |
Portable and stationary electrical generators became quite popular in Iraq soon after the shortage in national electrical
energy after 2003. Multi step risk assessment process is used in this study in the assessment of risks caused by
contamination of indoor air by lead particles emitted from domestic electrical generators. Two portable electrical
generators are tested under controlled indoor conditions (Radial LG (0.9 keV) fueled with benzene and oil and TigMax
(3 keV), fueled with benzene only). Lead particles in air were sampled by using portable dust sampler (Sniffer, L-30).
The atmospheric particulate sampling process is carried out in a flat located in the first floor of a three stories building
located in Baghdad
Optimization of gas lift plays a substantial role in production and maximizing the net present value of the investment of oil field projects. However, the application of the optimization techniques in gas lift project is so complex because many decision variables, objective functions and constraints are involved in the gas lift optimization problem. In addition, many computational ways; traditional and modern, have been employed to optimize gas lift processes. This research aims to present the developing of the optimization techniques applied in the gas lift. Accordingly, the research classifies the applied optimization techniques, and it presents the limitations and the range of applications of each one to get an acceptable level of accura
... Show MoreBackground: Pain due to muscular cramp during hemodialysis is one of the most common problems experienced by patient undergoing hemodialysis, and is associated with poor outcomes of patients. The main aim of this study was to comparing the effects of lavender oil and olive oil massage on Pain due to muscular cramp during hemodialysis.
Methods: In this random clinical trial, 60 hemodialysis patients were enrolled randomly and allocated to two groups with 30 members in Lordegan and Brojen hospitals, Shahrekord, Iran. The intervention included flora massage on the lower leg muscles so that the first group received olive oil massage (10 drops) and the second group received lavender oil massage (10 dr
... Show MoreConstruction projects are characterized as projects with multi phases and activities, complex, unique, and have many different parties and stakeholders. Risks could appear at one or more of the construction project stages and may affect the achievement of project objectives. Therefore, one of the key elements in the planning phase of any project is the risk management process (RMP). This study attempts to understand the terminology of risk in general, risk management, and response to risk in particular. This study is mainly a review of thirty-eight studies that have been published between 1997 and 2020 that demonstrate the importance of the crucial phase of risk response from the risk management process and its impact on
... Show MoreIn this research, the concentration of radon gas has been calculated in the classrooms of schools in Diyala Governorate by using the nuclear track detector (CR-39), which was one of the organic solid-state nuclear detectors (SSNTDs). After calculating the radon gas concentration, the lung cancer cases were calculated. The results showed that the lowest value was found in (Alshumue) school (4.753) people. In contrast, the highest value was found in (Habhib) school (20.421). The average values of lung cancer cases in Diyala governorate were equal to (9.319) per person. The results showed that the number of lung cancer cases per year per million persons in Diyala Governorate schools was below the allowed limit from (ICRP) agency (170-230) p
... Show More