A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.
The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.
PVC-LiF composites films with different lithium fluoride (LiF) concentrations (0, 30, 50, and 70 weight %) were prepared by using the casting method. This research deals with the investigation of dielectric properties for PVC-LiF composite films as a function of frequency and temperature in the ranges of 100 to 107 Hz and 293 - 370 K, respectively. The A.C activation energy values estimated from Arrhenius equation were 0.03820, 0.3174, 0.2009, and 0.1845 eV for the different PVC-LiF films with different LiF concentrations, respectively. It was found that the activation energy decreases by increasing LiF concentration and frequency. The exponent (s) showed a progressive increase with LiF for PVC-LiF films, while it showed
... Show MoreThis study aims to provide verification between measured and calculated radiation dose using three different ionization chamber detectors in Grid plans to select the best ones To the best of our knowledge, this is the first practical experiment in such subject. Grid radiotherapy is an unconventional method for bulky tumors treatment. It is characterized by a single-fraction and high radiation dose. Ten cases (scenarios) were selected to achieve Grid plans by MLCs, with a single dose of 1500-2000 cGy. Three ionization detectors were employed to measure the maximum, mean, and point doses (cGy), and match them with those calculated by the linear accelerator used in this study. The results showed significant differences among the th
... Show MoreA major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For
Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1
... Show MoreOptic Disc (OD) localization is a basic step for the screening, identification and appreciation of the risk of diverse ophthalmic pathologies such as glaucoma and diabetic retinopathy.In fact, the fundamental step towards an exact OD segmentation process is the success of OD localization. This paper proposes a fully automatic procedure for OD localization based on two of the OD most relevant features of high-intensity value and vasculature convergence. Merging ofthese two features renders the proposed method capable of localizing the OD within the variously complicated environments such as the faint disc boundary, unbalanced shading, and the existence of retinal pathologies like cotton wall and exudates,which usually share the same
... Show More In this work a Nd:YVO4 thin disc laser setup is designed and fabricated. The disk laser system
is designed to be compact. The laser crystal was pumped by a 808 nm diode laser. The effect of input
current and pulse frequency on the output energy at pulse operation mode, and the effect of the input
current on the output power at CW mode operation are tested. At the pulsed mode, the output energy
increased linearly with the input current and decreased with pulse frequency. The threshold current
increased with increasing pulse frequency increasing. The maximum output energy from the thin disc
laser was 0.98 μJ at 1.3 kHz frequency, with 0.49A. A minimum threshold current for CW mode of
operation. The maximum outpu
Background: Low back pain is the most common health problem in men and women between the ages of 20 and 50 years. The lumbar disc prolapse has a major role in this condition. Treatment is either conservative or surgical. The most common surgical interventions are either laminectomy or interlaminar approach.
Objective: To determine which is the best surgical approach for the patient according to his/her type of disc herniation.
Patients and methods: A comparative clinical study conducted in the Neurosciences Hospital, Baghdad, Iraq from January 2016 to January 2018. In this paper we evaluated the clinical outcome following both approaches
Results: