The infection with H. Pylori stimulates a signaling cascade that causes the generation of Cytokines and provokes Oxidative stress that is involved in the chronic inflammatory response leads to Gastric cancers. Reactive oxygen species (ROS) produce 8-Hydroxydeoxyguanosine (8-OHdG), the persistent oxidative DNA damage product. The study objective was to assess if there was a link between inflammatory cytokine levels and the presence of Oxidative DNA damage in Gastric tumor patients. In addition, evaluation of the diagnostic and prognostic value of Oxidative DNA damage and inflammatory cytokine biomarkers for Stomach cancers is being conducted. The study was accomplished on medically diagnosed Stomach cancer patients before any form of treatment. A total of 33 patients with Gastric cancers were selected and divided into Stages I, II, and III according to clinical pathology, and 32 age-matched healthy subjects as a control group. The Serum 8-OHdG, IL-6, TNF-α, IFN-γ & CEA were evaluated. The results revealed a highly significant rise (P<0.0001) in blood levels of 8-OHdG, TNF-α, & IFN-γ, and a non-significant (P=0.4747) increasing in IL-6 in GC patients compared to Controls, with levels gradually increasing as disease stages progressed. Furthermore, in GC patients, there was an insignificant (P=0.3472) positive correlation (r=0.1292) among 8-OHdG, IL-6, and CEA levels, but a noteworthy (P<0.0001) positive correlation (r=0.7235) among 8-OHdG, TNF-α, and CEA levels. In GC patients, however, there was an insignificant (P=0.6342) negative correlation (r=-0.06559) among 8-OHdG, IFN-γ, and CEA levels. The results of the current study show a strong link between serum levels of the 8-OHdG as well as inflammatory cytokines in GC patients. The significant enhancement in oxidative DNA damage, as well as overexpression of inflammatory cytokine biomarkers and CEA in the blood suggests that Oxidative stress and chronic inflammation are included in GC carcinogenesis. These observations suggest that 8-OHdG, TNF-α, & IFN-γ are viable biomarkers for the Gastric tumor prediction.
Mn2O3 was coated onto reduced titania nanotubes by reverse pulse electrodeposition, showing smooth and homogenous deposits without covering the opening of the nanotubes.
a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn
... Show MoreA new, simple and sensitive method was used forevaluation of propranolol withphosphotungstic acidto prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between propranolol and phosphotungstic acid in an aqueous medium to obtain a yellow precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.007-13 mmol/L for cell A and 5-15 mmol/L for cell B, and LOD 207.4792 ng/160 µL and 1.2449 µg/160 µL respectively to cell A and cell B with correlation coefficient (r) 0.9988 for cell A, 0.9996 for cell B, RSD% was lower than 1%, (n=8) for the
... Show Morenovel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show MoreBackground: The gene encoding a disintegrin and metalloproteinase domain 33 (ADAM33) is known to be associated with asthma in different ethnic groups. In Iraq, among the Arab ethnic background, this association has not yet been highlighted. Methods: One hundred and ninety-two asthmatics were examined; 118 males and 74 females (mean age 38.23 ± 9.13 years). The control group was 183; 110 males and the rest were females. The SNP of rs2280091 A/G (T1) was studied here to determine adam33 genotyping status using polymerase chain reaction–restriction fragment length polymorphism (PCR–RFLP). The level of total IgE was measured using enzyme-linked immunosorbent assay (ELISA). Results: Significant differences (p = 0.004) in the frequencies of
... Show MoreAbstract: The increased interest in developing new photonic devices that can support high data rates, high sensitivity and fast processing capabilities for all optical communications, motivates a pre stage pulse compressor research. The pre-stage research was based on cascading single mode fiber and polarization maintaining fiber to get pulse compression with compression factor of 1.105. The demand for obtaining more précised photonic devices; this work experimentally studied the behavior of Polarization maintaining fiber PMF that is sandwiched between two cascaded singe mode fiber SMF and fiber Bragg gratings FBG. Therefore; the introduced interferometer performed hybrid interference of both Mach-Zehnder
... Show MoreThis study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6
... Show MoreNH3 gas sensor was fabricated based on deposited of Functionalized Multi-Walled Carbon Nanotubes (MWCNTs-OH) suspension on filter paper substrates using suspension filtration method. The structural, morphological and optical properties of the MWCNTs film were characterized by XRD, AFM and FTIR techniques. XRD measurement confirmed that the structure of MWCNTs is not affected by the preparation method. The AFM images reflected highly ordered network in the form of a mat. The functional groups and types of bonding have appeared in the FTIR spectra. The fingerprint (C-C stretch) of MWCNTs appears in 1365 cm-1, and the backbone of CNTs observed at 1645 cm-1. A homemade sensi
... Show MoreUnderstanding breaking news necessitates a special attention, since they are written with a special style. The study aims at identifying the difficulties faced by the Iraqi university EFL learners in comprehending English breaking news. The study included 10 fourth year students enrolled at the Department of English, College of Education for Humanities, University of Anbar. Thus, a questionnaire as a research instrument, was sent online to the students. The questionnaire points were related to the identification of difficulties faced by the learners in comprehending English breaking news. The data of the study were (10) headlines selected purposively from Euronews website. The data were qualitatively analyzed based on quantifying the qua
... Show MoreAbstract: In the present work, the heat transfer of Nano Aluminum Oxide -NAO- has been studied practically to define the appropriate insulation conditions. This study focuses on finding of the amount of heat transfer through a glass substrate that is coated with nanoalumina doped on PMMA matrix. The optical and thermal properties were systematically investigated. The density of heat flow rate, was calculated in the range values (240-260) W/m2 while the optimum values confine between (250-260) W/m2 at temp. (25-35)Co. The results showed that the thermal insulation of the sample was significantly enhanced at temp. (30-50)Co. The simulated net heat transfer through window decreased linearly with incr
... Show More