Preferred Language
Articles
/
bsj-2069
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasin the amount ofcurrentconsumptionof the two systems at the same operating conditions.The currentconsumptionof the hybrid coolingsystemwith the changed tilt angle and replaced fluid wasless thantheunchanged oneby(38% - 58%), meaning that there was a current consumption saving as a result of tubes tilt angle and solar collector fluid changing.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Preparing New Ceramic Membranes from Syrian Zeolite Coated with Silver Nanoparticles to Treatment Wells Water
...Show More Authors

As a result of the exacerbation of the problem of water pollution, research was directed towards studying the treatment using ceramic membranes, which proved to be highly effective in treating all water sources. The research aims to study the possibility of preparing a new type of ceramic membranes from Syrian zeolite that was not previously used in this field. In this research, ceramic membranes were prepared from Syrian raw zeolite in several stages. Zeolite sample was characterized, grinded, mixed with boric acid, pressed to form desks, treated thermally according to experiment program, finally coated with silver nanoparticles. Specifications of prepared membranes were determined according to reference methods, effectiveness of prepar

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Osmotic Membrane Bioreactor for Oily Wastewater Treatment using External & Internal Configurations
...Show More Authors

The present work aims to study the treatment of oily wastewater by means of forward osmosis membrane bioreactor process. Side stream (external) configuration and submerged (internal) configuration of osmotic membrane bioreactor were performed and investigated. The experimental work for each configuration was carried out continuously over 21 days. The flux behavior of forward osmosis membrane in an osmotic membrane bioreactor (OMBR) was investigated, using NaCl as the draw solution and CTA as FO membrane. The effect of mixed liquor suspended solids (MLSS) concentration and TDS accumulation of bioreactor on water flux and membrane fouling behaviors was detected. The accumulation and rejection of nutrients in the bioreactor (Nitrate, COD,

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 05 2015
Journal Name
International Journal Of Current Engineering And Technology
Water Quality Index Assessment using GIS Case study: Tigris River in Baghdad City
...Show More Authors

In this study water quality index (WQI) was calculated to classify the flowing water in the Tigris River in Baghdad city. GIS was used to develop colored water quality maps indicating the classification of the river for drinking water purposes. Water quality parameters including: Turbidity, pH, Alkalinity, Total hardness, Calcium, Magnesium, Iron, Chloride, Sulfate, Nitrite, Nitrate, Ammonia, Orthophosphate and Total dissolved solids were used for WQI determination. These parameters were recorded at the intakes of the WTPs in Baghdad for the period 2004 to 2011. The results from the annual average WQI analysis classified the Tigris River very poor to polluted at the north of Baghdad (Alkarkh WTP) while it was very poor to very polluted in t

... Show More
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Science
Using Remote Sensing Coupled with Analytic Hierarchy Process Approach for Evaluating Water Harvesting in Baglia Site
...Show More Authors

    This research involves the application of spectral indices and GIS techniques coupled with the Analytic Hierarchy Process, to assess  Baglia site, eastern Missan, as a water harvesting potential site. The AHP and pairwise comparison have been used through select four criteria including TWI, TRI, MNDWI, and NDSI, which were deemed as impact factors for this study. All these criteria have been weighted according to their significance in the water harvesting system. The findings of the AHP analysis method explained that the WH potential zones in Baglia site were divided into three zones, namely, high,  medium, and low suitability. The findings demonstrate that  Bglia site, where the highly appropriate zone is located in the deep v

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Plant Archive
Furrow irrigated raised bed (firb) technique for improving water productivity in Iraq
...Show More Authors

A field experiment was conducted during the agricultural season 2017-2018. In the research station of the Ministry of Agriculture AL Rasheed side, and within the activities and researches of the national program to develop wheat cultivation in Iraq, Two factors were experienced in the cultivation of wheat, The first factor is the method of cultivation of five treatments were used: : Treatment of the cultivation of wheat in the plots (B), Treatment of wheat crops on bed with 50 cm width (S1), 60cm (S2), 70cm (S3) and 80cm (S4), The second factor is irrigation levels depletion of 40, 60 and 80% of available water coded as W1, W2 and W3, respectively, The experiment was designed under randomized complete block design (RCBD) with three replicat

... Show More
Preview PDF
Scopus (2)
Scopus
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Ethanol-Water Separation by Pressure Swing Adsorption (PSA)
...Show More Authors

Single long spiral tube column pressure swing adsorption (PSA) unit, 25 mm diameter, and 6 m length was constructed to study the separation of water from ethanol at azeotropic concentration of 95 wt%. The first three meters of the column length acted as a vaporizer and the remaining length acted as an adsorber filled by commercial 3A zeolite. The effect of pressure, temperature and feed flow rate on the product ethanol purity, process recovery and productivity were studied. The results showed that ethanol purity increased with temperature and pressure and decreased with feed flow rate. The purity decreased with increasing productivity. The purity range was 98.9 % to 99.6 %, the recovery range was 0.82 to 0.92 and the productivity range w

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad
...Show More Authors

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that th

... Show More
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad
...Show More Authors

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 09 2015
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Variations Heavy Metals Concentrations in Tigris River in Baghdad City.: Variations Heavy Metals Concentrations in Tigris River in Baghdad City.
...Show More Authors

The aim of the research is the detection of heavy metals using (Inductively coupled Plasma ICP) for samples in Tigris river at intakes of water treatment plants Baghdad (Sharq dejla, Al-Wathba, Al-Wahda, and Al-Dora) and samples at Tigris banks near (Al-Adhamya, Al-Shuhda bridge and al-Jadrya).
All the recorded results were fitted with Iraqi standers No. 25 in 1967 for all samples with heavy metals (arsenic Ar, Cadmium Cd, Chromium Cr, Zinc Zn, Lead Pb, Copper Cu, Nickel Ni, Manganese Mn, Ferrous Fe) where all concentration were lower than standard values except Cadmium (0.01- 0.014) in plants intakes and (0.027- 0.048) in river samples while the standard value is (0.005).
Other tests such as chemical oxygen demand and oil &

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Using Environmental Isotopes for Water Resources Evaluation in Altun Kopri Basin, NE Kirkuk
...Show More Authors

Recently, the environmental isotopes are adopted to figure out the hydrological processes, recharge areas, flow paths, groundwater origin and the interaction between different watery bodies. Currently, five samples of the rainwater have been collected since January to April 2012, as well as December 2011. Those sampling periods have highest amounts of precipitation events. Meantime, 25 samples of groundwater, 5 of the Lesser Zab River and 3 of overland flow have been picked up during the wet period. The dry sampling of groundwater and the Lesser Zab River has been achieved in summer 2011. The Local Meteoric Water Line lies between Global Meteoric Water Line (GMWL) and East Mediterranean Water Line (EMWL). The lowest, highest and

... Show More
View Publication Preview PDF