Preferred Language
Articles
/
bijps-367
Bioequivalence and Pharmacokinetics Comparison of Two Formulations of Extended-Release Pentoxifylline Tablets in Healthy Subjects after Fasting and Fed Conditions
...Show More Authors

The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples were withdrawn from each volunteer over 24 hours period.  Pentoxifylline concentrations were determined in plasma by a validated HPLC method according to FDA Bioanalytical Method Validation Guidance using UV detection and chloramphenicol as internal standard. The lower limit of quantitation of the drug in plasma was 5 ng/ml and the upper limit of quantitation was 500 ng/ml. From the plasma concentration-time data of each individual, the pharmacokinetic parameters; Cmax,  AUC0-t, AUC0-Â¥, Cmax/AUC0-Â¥, Tmax, lZ & T0.5; were calculated applying non-compartmental analysis. Data of the test and reference products were statistically analyzed to test for bioequivalence of the two products, using criteria of FDA and EMEA Guidance.  The pharmacokinetic parameters mentioned above were statistically analyzed by descriptive statistics, ANOVA test and 90% Confidence Interval (CI). ANOVA test involved the calculation of the effects of: treatment, period, sequence and subjects nested in sequence. According to the above guidance, the primary pharmacokinetic parameters used for bioequivalence testing, namely Cmax, AUC0-t and AUC0-Â¥ were also statistically analyzed by ANOVA & CI tests using the corresponding Ln-transformed values. The mean values  Cmax,  AUC0-t , AUC0-Â¥ , Cmax/AUC0-Â¥ , Tmax, lZ & T0.5 for the test formula obtained from the fasting study  were; 144.4 ng/ml,  845.4 ng.hr/ml, 868.4 ng.hr/ml, 0.186 hr-1, 3.29 hr, 0.561 hr-1 and 1.65 hr, respectively; and the mean values of these parameters for the reference formula were; 150.0 ng/ml,  871.1 ng.hr/ml, 893.7 ng.hr/ml, 0.177 hr-1, 3.70 hr, 0.558 hr-1 and 1.59 hr,  respectively.  The mean values of the above mentioned parameters for the test formula obtained from the fed study were; 157.8 ng/ml, 826.5 ng.hr/ml, 853.8 ng.hr/ml, 0.198 hr-1, 5.4 hr, 0.458 hr-1 and 2.06 hr, respectively; and the mean values of these parameters for the reference formula were; 162.1 ng/ml, 869.7 ng.hr/ml, 894.8 ng.hr/ml, 0.196 hr-1, 4.1 hr, 0.525 hr-1 and 1.80 hr, respectively.  Based on criteria of FDA and   EMEA Guidance on Bioavailability and Bioequivalence, the results of the fasting and fed studies demonstrated bioequivalence of the two products under either condition. Accordingly, it is concluded that the newly developed ER tablet containing 400 mg pentoxifylline is bioequivalent to Trental® 400 mg ER tablet produced by Sanofi-Aventis.

Keywords: Pentoxifylline, Pharmacokinetics, Bioequivalence.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 18 2023
Journal Name
Journal Of Research In Medical And Dental Science
Morphologic Evaluation of the Permanent Mandibular First Molar within an Iraqi Population Using Cone Beam Computed Tomography (Retrospective Study)
...Show More Authors

Preview PDF
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Ecological Engineering
Enhancing the Removal of Methyl Orange Dye by Electrocoagulation System with Nickel Foam Electrode – Optimization with Surface Response Methodology
...Show More Authors

Azo dyes like methyl orange (MO) are very toxic components due to their recalcitrant properties which makes their removal from wastewater of textile industries a significant issue. The present study aimed to study their removal by utilizing aluminum and Ni foam (NiF) as anodes besides Fe foam electrodes as cathodes in an electrocoagulation (EC) system. Primary experiments were conducted using two Al anodes, two NiF anodes, or Al-NiF anodes to predict their advantages and drawbacks. It was concluded that the Al-NiF anodes were very effective in removing MO dye without long time of treatment or Ni leaching at in the case of adopting the Al-Al or NiF-NiF anodes, respectively. The structure and surface morphology of the NiF electrode were inves

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Thu Mar 06 2025
Journal Name
Modern Sport
Determining standard levels to test the strength endurance characteristic of speed for basketball players for juniors aged under (16) years
...Show More Authors

View Publication
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Biosciences
Detection of Escherichia coli O157 H7 isolated from infected dogs with urinary tract infections using real time - polymerase chain reaction
...Show More Authors

Publication Date
Sun Jan 01 2023
Journal Name
Desalination And Water Treatment
Optimization of chemical oxygen demand removal from petroleum refinery wastewater by electrocoagulation using tubular electrochemical reactor with a novel design
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri May 19 2017
Journal Name
International Journal Of Environment, Agriculture And Biotechnology 2 (4 …‏
Effect of Knives Type on Some Operational Characteristics fora Locally Assembly Motorized Vibration Cutter Used for Date Palm Fronds Pruning‏
...Show More Authors

Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect Different Radioactive Dose on Mechanical Properties of Composite Material from Novolak Resin Exposure to High – Energy Radiation
...Show More Authors

The research involves using phenol – formaldehyde (Novolak) resin as matrix for making composite material, while glass fiber type (E) was used as reinforcing materials. The specimen of the composite material is reinforced with (60%) ratio of glass fiber.

      The impregnation method is used in test sample preparation, using molding by pressure presses.

      All samples were exposure to (Co60) gamma rays of an average energy (2.5)Mev. The total doses were (208, 312 and 728) KGy.

      The mechanical tests (bending, bending strength, shear force, impact strength and surface indentation) were performed on un irradiated and irrad

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Journal Of Science
An Integrated Information Gain with A Black Hole Algorithm for Feature Selection: A Case Study of E-mail Spam Filtering
...Show More Authors

     The current issues in spam email detection systems are directly related to spam email classification's low accuracy and feature selection's high dimensionality. However, in machine learning (ML), feature selection (FS) as a global optimization strategy reduces data redundancy and produces a collection of precise and acceptable outcomes. A black hole algorithm-based FS algorithm is suggested in this paper for reducing the dimensionality of features and improving the accuracy of spam email classification. Each star's features are represented in binary form, with the features being transformed to binary using a sigmoid function. The proposed Binary Black Hole Algorithm (BBH) searches the feature space for the best feature subsets,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jan 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Assessment of Long Distance Chasing Photometer (NAG-ADF-300-2) by Estimating the Drug Atenolol with Povidone Iodine Via CFIA
...Show More Authors

     Atenolol was used with povidone iodine to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and povidone iodine in an aqueous medium. Optimum parameters was studied to increase the sensitivity development of method. Calibration graph was linear in the range of 2-19 mmol/L for cell A and 5-19 mmol/L for cell B. Limit of detection 146.4848 ng/55 µL and 2.6600 µg/200 µL respectively to cell A and cell  B. Correlation coefficient (r) 0.9957 for cell A and 0.9974 for cell. Relative standard deviation (RSD %) was lower than 1%, (n=8) for the determination of

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Use aggregate slide estimate additive splines estimation for the diagnosis of non-linear composite model self-regression with practical application
...Show More Authors

Nonlinear time series analysis is one of the most complex problems ; especially the nonlinear autoregressive with exogenous variable (NARX) .Then ; the problem of model identification and the correct orders determination considered the most important problem in the analysis of time series . In this paper , we proposed splines  estimation method for model identification , then we used three criterions for the correct orders determination. Where ; proposed method used to estimate the additive splines for model identification , And the rank determination depends on the additive property  to avoid the problem of curse dimensionally . The proposed method is one of the nonparametric methods , and the simulation results give a

... Show More
View Publication Preview PDF
Crossref