This research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of disease and morbidity of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of this frequency with the angles of transitions and receptions and the effect of changing the ultrasound transmitted frequencies on the measured velocities .The Doppler ultrasound system has been used which is more efficient and easier to be widely used as a practical application in Al Yarmouk Teaching Hospital on two subjects. The normal had a natural medical history in the blood vessels, and abnormal had carotid artery stenosis. This device will give the flow velocity of blood in the blood vessels which is useful to the examiner, the equation of Doppler as a mathematical model in the research is adopted the measured speed to clarify the amount of change in the frequency (shift in frequency). This speed was measured in five different blood vessels, large arteries (abdominal aorta and carotid artery in the neck) and large veins (the inferior vena cava across the abdomen and the external Jugular vein in the neck) and capillaries in the hand and fingers. Then using the measured velocities in these vessels the Doppler frequency was calculated from this mathematical model using MATLAB program, was found that as velocity of the blood increases, so does the Doppler frequency and vice versa. The greater the value of the Doppler angle used in the device then the Doppler frequency decreased and vice versa. As well as increasing the transmitted frequency giving an increase in the speed of blood flow and in the Doppler frequency and vice versa. It was observed during the practical work that it was possible to get the speed of blood flow in different blood vessels, arteries and veins easily, but to less extent in the capillary vessels since in fact the value of the received frequency was very small.
Pulsed liquid laser ablation is considered a green method for the synthesis of nanostructures because there are no byproducts formed after the ablation. In this paper, a fiber laser of wavelength 1.064 µm, peak power of 1 mJ, pulse duration of 120 ns, and repetition rate of 20 kHz, was used to produce carbon nanostructures including carbon nanospheres and carbon nanorods from the ablation of asphalt in ethanol at ablation speeds of (100, 75, 50, 10 mm/s). The morphology, composition and optical properties of the synthesized samples were studied experimentally using FESEM, HRTEM, EDS, and UV-vis spectrophotometer. Results showed that the band gap energy decreased with decreasing the ablation speed (increasing the ablation time), the mi
... Show MoreThis study proposes a mathematical approach and numerical experiment for a simple solution of cardiac blood flow to the heart's blood vessels. A mathematical model of human blood flow through arterial branches was studied and calculated using the Navier-Stokes partial differential equation with finite element analysis (FEA) approach. Furthermore, FEA is applied to the steady flow of two-dimensional viscous liquids through different geometries. The validity of the computational method is determined by comparing numerical experiments with the results of the analysis of different functions. Numerical analysis showed that the highest blood flow velocity of 1.22 cm/s occurred in the center of the vessel which tends to be laminar and is influe
... Show MoreBackground: Low hemoglobin levels and lead exposure remain significant health issues in many parts of the world, often occurring together, however most of the researches concentrate on the effect of high levels of lead .This study aimed to demonstrate the effect of blood lead level on hemoglobin and packed cell volume (PCV).
Patients and Methods: Fifty eight adult volunteers were enrolled in this study with age range between 23 and 55 years, working in the different departments in medical college of Baghdad University. Whole blood was withdrawn in EDTA tubes. Hemoglobin and PCV were measured and blood lead level was estimated using blood lead testing system including lead care kit and lead care analyzer.
Results: After measuring bl
The Nano materials play a very important role in the heat transfer enhancement. An experimental investigation has been done to understand the behaviors of nano and micro materials on critical heat flux. Pool boiling experiments have used for several concentrations of nano and micro particles on a 0.4 mm diameter nickel chrome (Ni-Cr) wire heater which is heated electrically at atmospheric pressure. Zinc oxide(ZnO) and silica(SiO2) were used as a nano and micro fluids with concentrations (0.01,0.05,0.1,0.3,0.5,1 g/L), a marked enhancement in CHF have been shown in the results for nano and micro fluids for different concentrations compared to distilled water. The deposition of the nano particles on the heater surface was the rea
... Show MoreBackground: dyspepsia is a common complaint, affecting about 26-41% of the general population. Investigations fail to identify organic cause in 50%–60% of functional dyspepsia. Little informations are available about whether quick eating is one of the risk factors for functional dyspepsia (FD).
Objectives: To study the association between quick eating and FD.
Materials and methods: The study was performed on 132 resident doctors in the medical city/Baghdad, by introducing a questionnaire derived from the Rome III criteria for diagnosis of FD and its subtypes and calculating the average daily meal duration for each one. The subjects were all Arabian, Iraqi, white resident doctors sharing the same type and amount of food. We exclud
Background: Profound alterations of respiratory function physiology accompany pregnancy; these conditions contribute to many of the disorders of the lung during pregnancy. The adaptive changes during the gravid period are designed to support maternal and fetal well-being during the special stresses of fetal growth and parturition Peak.
Objective: This study aimed to know the effect of pregnancy on peak expiratory flow rate in comparison with non-pregnant Iraqi women.
Method: This study was conducted on 255 healthy female at their reproductive ages , made up of 60 pregnant female in 1st trimester , 65 in 2nd trimester , 60 in 3rd trimester and 70 non pregnant as control group.
Results: There were a significant negative relation b
The current research deals with short term forecasting of demand on Blood material, and its' problem represented by increasing of forecast' errors in The National Center for Blood Transfusion because using inappropriate method of forecasting by Centers' management, represented with Naive Model. The importance of research represented by the great affect for forecasts accuracy on operational performance for health care organizations, and necessity of providing blood material with desired quantity and in suitable time. The literatures deal with subject of short term forecasting of demand with using the time series models in order to getting of accuracy results, because depending these models on data of last demand, that is being sta
... Show MoreAbstract
The current research sought to demonstrate the effect of material flow cost accounting on reducing products through the application of material flow cost accounting technique, which works on the optimal utilization of materials and energy and the reduction of environmental impacts.The research aims to clarify the knowledge foundations for material flow cost accounting, in addition to studying the material flow cost accounting technique that helps reduce the cost of products and make them environmentally friendly. To achieve this, the research relied on the descriptive approach with regard to the theoretical aspect of the resea
... Show MoreThe first studies on shocks and vibrations were carried out at the beginning of the 1930s to improve the behavior of buildings during earthquakes. Vibration tests on aircraft were developed from 1940 to verify the resistance of parts and equipments prior to their first use. Flutter is a well-known example of dynamic aero elasticity, where when oscillation of structure interacted with unsteady aerodynamic forces the flutter will occur. Vibration on any structure without damping means that self-harmonic oscillation will occur, and in most cases the oscillation may start to increase until structural failure. This behavior is very similar to resonance phenomena if only the oscillation is being studied as a vibration case. In vibration suppre
... Show MoreBlockchain is an innovative technology that has gained interest in all sectors in the era of digital transformation where it manages transactions and saves them in a database. With the increasing financial transactions and the rapidly developed society with growing businesses many people looking for the dream of a better financially independent life, stray from large corporations and organizations to form startups and small businesses. Recently, the increasing demand for employees or institutes to prepare and manage contracts, papers, and the verifications process, in addition to human mistakes led to the emergence of a smart contract. The smart contract has been developed to save time and provide more confidence while dealing, as well a
... Show More