This study aims to explore the potential mediation role of person-centeredness between the effects of the work environment and nurse reported quality and patient safety. A quantitative cross-sectional survey collected data from 1055 nurses, working in medical and surgical units, in twelve Malaysian private hospitals. The data collection used structured questionnaires. The Hayes macro explored the mediation effect of person-centeredness between the associations of work environment dimensions and care outcomes, controlling nurses’ demographics and practice characteristics. A total of 652 nurses responded completely to the survey (61.8% response rate). About 47.7% of nurses worked 7-h shifts, and 37.0% were assigned more than 15 patients. Higher workload was associated with unfavorable outcomes. Nurses working in 12-h shifts reported a lower work environment rating (3.46 ± 0.41, p < 0.01) and person-centered care (3.55 ± 0.35, p < 0.01). Nurses assigned to more than 15 patients were less likely to report a favorable practice environment (3.53 ± 0.41, p < 0.05), perceived lower person-centered care (3.61 ± 0.36, p < 0.01), and rated lower patient safety (3.54 ± 0.62, p < 0.05). Person-centeredness mediates the effect of nurse work environment dimensions on quality and patient safety. Medical and surgical nurses, working in a healthy environment, had a high level of person-centeredness, which, in turn, positively affected the reported outcomes. The function of person-centeredness was to complement the effects of the nurse work environment on care outcomes. Improving the nurse work environment (task-oriented) with a high level of person-centeredness (patient-oriented) was a mechanism through which future initiatives could improve nursing care and prevent patient harm.
As a result of rapid industrialization and population development, toxic chemicals have been introduced into water systems in recent decades. Because of its excellent efficiency and simple design, the three-dimensional (3D) electro-Fenton method has been used for the treatment of wastewater. The goal of the current study is to explore the efficiency of phenol removal by the 3D electro-Fenton process, which is one of the advanced oxidation processes (AOPs). In the present work, the effect of the addition of granular activated carbon (GAC) particles to the electro-Fenton system as the third electrode would be investigated in the presence of graphite as the anode and nickel foam as the cathode, which is the source of electro-generated hydrogen
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreThe Asymmetrical Castellated concavely – curved soffit Steel Beams with RPC and Lacing Reinforcement improves compactness and local buckling (web and flange local buckling), vertical shear strength at gross section (web crippling and web yielding at the fillet), and net section ( net vertical shear strength proportioned between the top and bottom tees relative to their areas (Yielding)), horizontal shear strength in web post (Yielding), web post-buckling strength, overall beam flexure strength, tee Vierendeel bending moment and lateral-torsional buckling, as a result of steel section encasement. This study presents two concentrated loads test results for seven specimens Asymmetrical Castellated concavely – curved soffit Steel Be
... Show MoreTo assess the biochemical, mechanical and structural characteristics of retained dentin after applying three novel bromelain‑contained chemomechanical caries removal (CMCR) formulations in comparison to the conventional excavation methods (hand and rotary) and a commercial papain‑contained gel (Brix 3000). Seventy‑two extracted permanent molars with natural occlusal carious lesions (score > 4 following the International Caries Detection and Assessment System (ICDAS‑II)) were randomly allocated into six groups (n = 12) according to the excavation methods: hand excavation, rotary excavation, Brix 3000, bromelain‑contained gel (F1), bromelain‑chloramine‑T (F2), and bromelain chlorhexidine gel (F3). The superficial and deepe
... Show MoreSpectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreThis research investigates manganese (Mn) extraction from Electric Arc Furnace Steel Slag (EAFS) by using the Liquid-liquid extraction (LLE) method. The chemical analysis was done on the slag using X-ray fluorescence, X-ray diffraction, and atomic absorption spectroscopy. This work consisted of two parts: the first was an extensive study of the effect of variables that can affect the leaching process rate for Mn element from slag (reaction time, nitric acid concentration, solid to liquid ratio, and stirring speed), and the second part evaluates the extraction of Mn element from leached solution. The results showed the possibility of leaching 83.5 % of Mn element from the slag at a temperature of 25°C, nitric acid co
... Show MoreThe chronic renal disease is a principle common medical dilemma in Iraq. Peripheral arterial disease (PAD) is a prevalent infirmity in the hemodialysis people. The aim of present study was to estimate the prevalence of PAD in subjects with end-stage renal disease (ESRD). This cross-sectional study was done between January 2016 and May 2017 on ESRD subjects regularly attending renal dialysis unit in Al-Kindy teaching hospital in Baghdad, Iraq. PAD was diagnosed on the base of the ankle-brachial index (ABI) measured by using a hand-held Doppler ultrasound. Subjects with ABI ≤0.9 were supposed positive for PAD. A total of 150 ESRD cases were analyzed. The mean age of the subject was 49.52±15 years. Majority of them were males 87(58%). Most
... Show More