To assess the use of miniaturized percutaneous nephrolithotomy (mini-PCNL) for renal stones in children, as well as its safety and efficacy. Seventy-seven patients with more than 15 mm renal stones whose age was less than 15 years were enrolled in this prospective case-controlled study at Al-Ramadi Teaching Hospital, Ar Razi Private Hospital, and Ghazi Al-Hariri Hospital for Surgical Specialties, Anbar and Baghdad, Iraq. The study was conducted from January 2020 to January 2024. The group mentioned above served as group A, and it was compared to the control group (group B), which consisted of 70 adult patients aged 18–60 years. Patients in both groups underwent mini-PCNL. Gender, stone size and location, time of operation, stone-free rate, hemoglobin drop, need for blood transfusion, postoperative fever, associated visceral injury, and need for further interventions such as extracorporeal shock wave lithotripsy or flexible ureteroscopy (ESWL or FURS) were compared in both groups. The age of patients in group A ranged from 8 months to 15 years with a mean (4.30 ± 3.16), while in group B ranged from 18 to 60 years with a mean (36.3 ± 12.0), p-value 0.001. There were no statistically significant differences regarding gender distribution, stone size, and location, p-value > 0.05. The stone-free rate was 87.01% for group A and 88.57% for group B, with no statistical difference, p-value 0.773. Hemoglobin drop was 1.096 ± 0.412 for group A and 1.195 ± 0.110 for group B, p-value 0.046. Blood transfusion was needed in one case in each group with no statistical difference, p-value 0.946. The need for ESWL was 3 cases in group A, and 2 cases in group B, with no statistical difference between the two groups, p-value 0.729. The need for FURS was 4 cases in group A and 3 cases in group B, p-value 0.796. Operative time was 30 to 125 min in group A and 34 to 129 min in group B, p-value 0.941. Postoperative fever was seen in 23 cases in group A and 21 cases in group B, p-value 0.986. Minor liver injury was seen was seen in one case in each group. The use of mini-PCNL for treating renal stones in children is safe and effective as it is associated with a relatively low rate of significant complications and achieves a high stone-free rate.
Erratum for Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.
This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreThe gas sensing properties of Co3O4and Co3O4:Y nano structures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for Co3O4and Co3O4:Y thin films. XRD analysis shows that all films are polycrystalline in nature, having a cubic structure, and the crystallite size is (11.7)nm for cobalt oxide and (9.3)nm for the Co3O4:10%Y. The SEM analysis of thin films obviously indicates that Co3O4possesses a nanosphere-like structure and a flower-like structure for Co3O4:Y.The sensitivity, response time and recovery time to a H2S reducing gas were tested at different operating
... Show Moreچکیدهی بحث
به نظر میآید که عالم هستی ، بر مسألهی « حرکت» استوار دارد ، و روح ، همیشه دنبال دگرگونی و تکامل و برتری میگردد. حرکت ، همهی چیزها در عالم إمکان را در بر میگیرد. حرکت در بنیادهای فکر مولانا جای مهمی دارد .اشعار مولانا مقدار زیادی از پویایی و حرکت برخوردارست، و از آنجایی که فعل ، عنصر تکانبخش جمله ، و کانون دلالت است ، ترجیح دادیم - علاوه بر دیگر عنا
... Show MoreThe adsorption ability of Iraqi initiated calcined granulated montmorillonite to adsorb Symmetrical Schiff Base Ligand 4,4’-[hydrazine-1, 2-diylidenebis (methan-1-yl-1-ylidene)) bis (2-methoxyphenol)] derived from condensation reaction of hydrazine hydrate and 4-hydroxy-3-methoxybenzaldehyde, from aqueous solutions has been investigated through columnar method.The ligand (H2L) adsorption found to be dependent on adsorbent dosage, initial concentration and contact time.All columnar experiments were carried out at three different pH values (5.5, 7and 8) using buffer solutions at flow rate of (3 drops/ min.),at room temperature (25±2)°C. The experimental isotherm data were analyzed using Langmuir, Freundlich and Temkin equations. The monol
... Show More