Background Type two diabetes (T2DM) is characterized by insufficient insulin production and secretion. Additionally, the body develops insulin resistance which affects 90–95% of diabetics. Complex cytokines, receptors, genetic pathways, and the immune system are involved in T2DM. Interleukin-18 (IL-18) is one of the inflammatory cytokines associated with Type 2 diabetes. Environmental and genetic variables, including genetic polymorphisms, can increase T2DM risk and its consequences. Single nucleotide gene polymorphisms (SNPs) are important risk factors for diabetes that can be used to find the disease early and treat it better. Objective This study aimed to determine the levels of IL-18 in the serum of Iraqi patients with Type 2 diabetes mellitus, as well as the effect of IL-18 SNP rs1946518 (-607 G/T) in the etiology of T2DM. Materials and Methods This study involved 100 T2DM patients (52 males and 48 females) who visited Al-Karamah Teaching Hospital and Baghdad Teaching Hospital. 52 Iraqi control subjects (26 males and 26 females) were included. A sandwich enzyme-linked immunosorbent assay was used to quantify the IL-18 serum levels of 48 patients and 40 healthy controls. The genotype of IL-18 was determined using Real-time (RT) Taqman PCR. Results According to age, the current study revealed a non-significant correlation (p-value > 0.05) among the studied groups. IL-18 levels in the T2DM group were substantially greater than in the healthy control. In addition, the genotyping frequencies revealed that the frequency of TT genotyping was higher in T2DM group than in healthy control (80% versus 66.7%, OR: 2.0), whereas the frequency of GT genotyping was lower in T2DM than in healthy persons (20% versus 33.3%, OR: 0.5). Conclusion: This Iraqi’s novel study indicated that IL-18 and it’s SNP(rs1946518) contributes to the pathophysiology of Type 2 diabetes mellitus.
The manganese doped zinc sulfide nanoparticles were synthesized by simple aqueous chemical reaction of manganese chloride, zinc acetate and thioacitamide in aqueous solution. Thioglycolic acid is used as capping agent for controlling the nanoparticle size. The main advantage of the ZnS:Mn nanoparticles of diameter ~ 2.73 nm is that the sample is prepared by using non-toxic precursors in a cost effective and eco-friendly way. The structural, morphological and chemical composition of the nanoparticles have been investigated by X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) with energy dispersion spectroscopy (EDS) and Fourier transform infrared (FTIR) spectroscopy. The nanosize of the prepared nanoparticles was elucidated by Scan
... Show MoreThe Asymmetrical Castellated concavely – curved soffit Steel Beams with RPC and Lacing Reinforcement improves compactness and local buckling (web and flange local buckling), vertical shear strength at gross section (web crippling and web yielding at the fillet), and net section ( net vertical shear strength proportioned between the top and bottom tees relative to their areas (Yielding)), horizontal shear strength in web post (Yielding), web post-buckling strength, overall beam flexure strength, tee Vierendeel bending moment and lateral-torsional buckling, as a result of steel section encasement. This study presents two concentrated loads test results for seven specimens Asymmetrical Castellated concavely – curved soffit Steel Be
... Show MoreIn this research study the effect of irradiation by (CW) CO2 laser on some optical properties of (Cds) doping by Ni thin films of (1)µm thickness has been prepared by heat evaporation method. (X-Ray) diffraction technique showed the prepared films before and after irradiation are ploy crystalline hexagonal structure, optical properties were include recording of absorbance spectra for prepared films in the range of (400-1000) nm wave lengths, the absorption coefficient and the energy gap were calculated before and after irradiation, finally the irradiation affected (CdS) thin films by changing its color from the Transparent yellow to dark rough yellow and decrease the value absorption coefficient also increase the value of energy gap.
Water quality planning relies on Biochemical Oxygen Demand BOD. BOD testing takes five days. The Particle Swarm Optimization (PSO) is increasingly used for water resource forecasting. This work designed a PSO technique for estimating everyday BOD at Al-Rustumiya wastewater treatment facility inlet. Al-Rustumiya wastewater treatment plant provided 702 plant-scale data sets during 2012-2022. The PSO model uses the daily data of the water quality parameters, including chemical oxygen demand (COD), chloride (Cl-), suspended solid (SS), total dissolved solids (TDS), and pH, to determine how each variable affects the daily incoming BOD. PSO and multiple linear regression (MLR) findings are compared, and their performance is evaluated usin
... Show MoreThe General Company for Iraqi Cement is regarded as one of the companies that contribute to support the Iraqi economy. It contributes to provide the material of cement which fulfils the consumer and investment need in the markets in competitive prices and not to resort to the importing of the cement from abroad. That would save a great share of the purchase parity of the poor sectors of society. The estimation of production function will contribute to putting the company.
The application functions of the standard production of benefit critical to clarify the actual relationship between production & its components, & allow to clarify the i
... Show MoreThe present study employed the NAG-4SX3-3D analyzer to precisely measure the energy response of the sensor. The goal was to enhance the understanding of this technology by providing expert information about the device. This technology offers an economical, quick, accurate, and sensitive approach. By utilizing the turbidity method, Cyproheptadine hydrochloride (CPH) was quantified in pharmaceutical samples without the need for additional substances. CPH is expected to undergo a direct reaction with calcium hexacyanoferrate, resulting in the formation of white precipitates. The linear range for CPH measurement falls within the range of (0.008–30) mM. The relative standard deviation (RSD) for six repetitions at concentrations of (6 and
... Show More
