BACKGROUND: Polycystic ovary syndrome(PCOS) is one of the most common endocrine disorder affecting women in reproductive age. No single etiologic factor fully accounts for the spectrum of abnormalities in the polycystic ovary syndrome. Different changes in hormonal, metabolism and the inflammatory markers as squealy of PCOS with adverse effect on the women life. OBJECTIVE: To study the relationship between polycystic ovary syndrome and levels of C-reactive protein, human interleukin and hormonal and metabolic alteration in women with PCOS PATIENTS AND METHODS: Thirty women with Polycystic Ovary syndrome (PCOS) and other thirty women without PCOS were included. Venous blood samples were taken in early follicular phase of menstrual cycle [day 2-6] for luteinizing hormone (LH), follicle-stimulating hormone (FSH), and testosterone. Serum level of Human Interleukin 1B (IL-1B) was quantitatively determined. Blood samples were also tested for detection of CRP (C-reactive protein, in addition to levels of cholesterol, triglycerides. RESULTS: The mean cholesterol level was significantly higher in PCOS group rather than controls; (188.3 ± 7.2) vs. (168.7 ± 6.1) respectively. Mean LH level was higher in PCOS women than control (13.3 ± 2.4 IU/L) vs. (5.85 ± 1.47) IU/L, while in contrary mean FSH level was lower in PCOS cases. The mean serum testosterone in PCOS group was significantly higher than in controls, with no significant difference regarding IL-1B, but again it was significant in cases of CRP. CONCLUSION: PCOS was associated with higher levels of cholesterol, LH, and serum testosterone with lower levels of FSH. Positive C-Reactive Protein was more frequent in PCOS cases. Still serum level of Human Interleukin 1B (IL-1B) was not significantly affected by PCOS.
The effect of White Place Image ( Test Image ) A4 has been studied as a function of luminous intensity using the t tu un ng gs st te en n l la am mpp and web camera enet. It was found that the tungsten lamp gives almost even intensities for the three color band and lighting composite at low voltage .while at high voltage causes a fare from each other . The statistical characteristic(mean and stander deviation ) results for three colors composites RGB and lighting composites L showed that the mean and stander deviation increases with the increase of voltage possibly owing to the increase image resolution, which reflects the value of stander deviation for the blue band
... Show MoreIn this work, wide band range photo detector operating in UV, Visible and IR was fabricated using carbon nanotubes (MWCNTs, SWCNTs) decorated with silver nanoparticles (Ag NPs). Silicon was used as a substrate to deposited CNTs/Ag NPs by the drop casting technique. Polyamide nylon polymer was used to coat CNTs/Ag NPs to enhance the photo-response of the detector. The electro-exploding wire technology was used to synthesize Ag NPs. Good dispersion of silver NPs achieved by a simple chemistry process on the surface of CNTs. The optical, structure and electrical characteristic of CNTs decorated with Ag NPs were characterized by X-Ray diffraction and Field Emission Scanning Electron Microscopy. X-ray diffra
... Show MoreKinetic experiments were performed to induce of the green methyl dye adsorption from aqueous solution on the bauxite clay. This study includes determination of the adsorption capacity of bauxite clay to methyl green dye adsorption and study the effect of some parameters ( temperature , time ) on the kinetic of the adsorption process of the dye were studied. Quantity of dye adsorbed was increased when the temperature increases from 298 to 318K which indicates that methyl green adsorption processes are endothermic nature . In order to describe the kinetic data and the rate adsorption constants of the pseudo-first-order and second-order kinetics were used . The kinetics data were applied well
... Show MoreIn this work a model of a source generating truly random quadrature phase shift keying (QPSK) signal constellation required for quantum key distribution (QKD) system based on BB84 protocol using phase coding is implemented by using the software package OPTISYSTEM9. The randomness of the sequence generated is achieved by building an optical setup based on a weak laser source, beam splitters and single-photon avalanche photodiodes operating in Geiger mode. The random string obtained from the optical setup is used to generate the quadrature phase shift keying signal constellation required for phase coding in quantum key distribution system based on BB84 protocol with a bit rate of 2GHz/s.
The success of endodontic therapy is relied on radicular system cleaning, shaping, elimination of micro-organisms, and three dimensional filling of the radicular complex.This study was conducted to develop and assess new root canal sealer incorporating nano-sized bioactive glass into Gutta Flow II. The following concentration was used depend on a pilot study included adding (3%) of 45S5 bioactive glass into the Gutta Flow II. These materials were tested through assessment bioactivity. bioactivity test was undertaken after immersion of the tested samples into PBS for three days, seven days, fourteen days, and twenty eight days using FTIR too. study was found that it’s peaks was appear at level 800-1000 cm-1. The results showed that GFII gr
... Show MoreIn this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing
... Show MoreBackground: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs) on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and
... Show More