Preferred Language
Articles
/
7xc3kpIBVTCNdQwCSrdB
Preparation, <i>In-vitro, Ex-vivo</i>, and Pharmacokinetic Study of Lasmiditan as Intranasal Nanoemulsion-based <i>In Situ</i> Gel
...Show More Authors
Background:

Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.

Objective:

This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.

Method:

Two successfully prepared nanoemulsion (NE) formulas, a and b, were selected for the incorporation of different percentages of pH-sensitive in situ gelling polymer (Carbopol 934) to prepare NEIGs 1, 2, 3, 4, 5, and 6. The pH, gelation capacity, gel strength, and viscosity were predicted for the prepared NEIGs. The release (in vitro) and the nasal permeation (ex vivo) were determined for NEIG 2 and 5, and then both were subjected to pharmacokinetics in vivo studies. Eighteen male rabbits weighing 2.0 to 2.5 kg were employed in the parallel design study. The body surface area (BSA) normalization method was applied for LAS dose calculation. Serial blood samples were taken out and subjected to drug analysis using the HPLC method previously developed and validated by Kumar et al. Primary pharmacokinetics parameters, including maximum drug concentration in plasma (Cmax), time to reach C-max (T-max), and area under the concentration-time curve from time zero to affinity (AUCt0-∞) were calculated. Both NE (a and b), together with NEIG (2 and 5) formulas, were subjected to the stability study. Finally, a nasal ciliotoxicity study was carried out to evaluate the nasal toxicity of developed NEIGs 2 and 5.

Result:

The results showed that NEIGs 2 and 5 could be selected as the optimized NEIGs as both achieved 100% permeation within 20 min and then released within 25 and 35 min, respectively, thus achieving 3.3 folds with higher permeation percentages as compared to the AQS. Both NEIGs 2 and 5 exerted comparable release and permeation values as the corresponding NE a and b with more residence time in order to overcome the normal nasal physiological clearance. The values of C-max, Tmax, and AUC0- ∞ for NEIG 2 and NEIG 5 were 8066 ± 242 ng/ml, 0.75 ± 0.05 h, 19616.86 ± 589 ng. h/ml, and 7975.67 ± 239 ng/ml, 1.0 ± 0.05 h, 17912.36 ± 537 ng. h/ml, respectively, compared to the traditional AQS, which is equal to 4181.09 ± 125 ng/ml, 2 ± 0.2 h, and 8852.27 ± 266 ng. h/ml, respectively. It was discovered that NEIGs 2 and 5 had better intranasal delivery of LAS and could significantly (p < 0.05) achieve a higher value of permeability coefficient (3.3 folds) and 2.5 folds improvement in bioavailability when compared to AQS. The NE a, NE b, NEIG2, and NEIG5 formulations showed good stability at various temperatures. According to the nasal ciliotoxicity study, the nasal mucosal membrane, which was treated with NEIG 5, showed irritation with a bit of damage. However, damage was not observed when it was treated with NEIG 2, indicating the biocompatibility of the last one to be selected as the optimum formula.

Conclusion:

NEIG 2 and NEIG 5 are promising new intranasal formulas with a faster onset of action and greater bioavailability than the oral dosage form (AQS). Finally, the selected optimum gold formula that will be ready for further clinical study is NEIG 2.

Scopus Crossref
View Publication
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Experimental Investigation of Natural Convection into a Horizontal Annular Tube with Porous Medium Effects
...Show More Authors

In this work, an experimental investigation has been done for heat transfer by natural-convection through a horizontal concentric annulus with porous media effects. The porous structure in gap spacing consists of a glass balls and replaced by plastic (PVC) balls with different sizes. The outer surface of outer tube is isothermally cooled while the outer surface of inner tube is heated with constant heat flux condition. The inner tube is heated with different supplied electrical power levels. Four different radius ratios of annulus are used. The effects of porous media material, particles size and annulus radius ratio on heat dissipation in terms of average Nusselt number have been analyzed.

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Design of Multi-Rate Multi-Zone Wireless Fuzzy Temperature Control System for Greenhouse Application
...Show More Authors

sensor sampling rate (SSR) may be an effective and crucial field in networked control systems.  Changing sensor sampling period after designing the networked control system is a critical matter for the stability of the system. In this article, a wireless networked control system with multi-rate sensor sampling is proposed to control the temperature of a multi-zone greenhouse. Here, a behavior based Mamdany fuzzy system is used in three approaches, first is to design the fuzzy temperature controller, second is to design a fuzzy gain selector and third is to design a fuzzy error handler. The main approach of the control system design is to control the input gain of the fuzzy temperature controller depending on the cur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Iraqi Journal Of Physics
Modifications to Accelerate the Iterative Algorithm for the Single Diode Model of PV Model
...Show More Authors

This paper discussed the solution of an equivalent circuit of solar cell, where a single diode model is presented. The nonlinear equation of this model has suggested and analyzed an iterative algorithm, which work well for this equation with a suitable initial value for the iterative. The convergence of the proposed method is discussed. It is established that the algorithm has convergence of order six. The proposed algorithm is achieved with a various values of load resistance. Equation by means of equivalent circuit of a solar cell so all the determinations is achieved using Matlab in ambient temperature. The obtained results of this new method are given and the absolute errors is demonstrated.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Al-academy
Applications of Interior Space Design According to Shape Generation Systems: عبد الكريم علي حسين
...Show More Authors

Treatises concerning analyzing the interior spaces multiplied and their directions varied, that some of them analyzed the interior space on the basis of the intellectual and philosophical affiliation or the historical period and others in the light of the concept and mechanisms of the shape. The researcher has not been able to find a research that dealt with analyzing the space within the systems of shape generation, thus it is possible to determine the research problem with the following question: to what extent is it possible to analyze the interior space based on systems of shape generation? As far as the importance of the research is concerned, it sheds light on five of the systems of the shape generation which are: Syntax, shape gra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Catalysis Science &amp; Technology
Mechanisms governing selective hydrogenation of acetylene over γ-Mo<sub>2</sub>N surfaces
...Show More Authors

We demonstrate that the selective hydrogenation of acetylene depends on energy profile of the partial and full hydrogenation routes and the thermodynamic stability of adsorbed C2H2 in comparison to C2H4.

View Publication
Scopus (27)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Finite Element Analysis of Cracked One-Way Bubbled Slabs Strengthened By External Prestressed Strands
...Show More Authors

Bubbled slabs can be exposed to damage or deterioration during its life. Therefore, the solution for strengthening must be provided. For the simulation of this case, the analysis of finite elements was carried out using ABAQUS 2017 software on six simply supported specimens, during which five are voided with 88 bubbles, and the other is solid. The slab specimens with symmetric boundary conditions were of dimensions 3200/570/150 mm. The solid slab and one bubbled slab are deemed references. Each of the other slabs was exposed to; (1) service charge, then unloaded (2) external prestressing and (3) loading to collapse under two line load. The external strengthening was applied using prestressed wire with four approaches, wh

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 02 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Fri Oct 01 2021
Journal Name
The Iraqi Postgraduate Medical Journal
Knowledge of Hypertensive Patients Attending Al-Imamein Kadhimein Medical City Regarding Follow-Up Visits
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Surface analysis of the PEKK coating on the cp ti implant using laser technique
...Show More Authors

Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an

... Show More
Preview PDF
Scopus (7)
Scopus
Publication Date
Wed Jun 02 2010
Journal Name
Journal Of Engineering
Bearing capacity of square footing on geogrid reinforced loose sand to resist eccentric load
...Show More Authors

This research presents and discuss the results of experimental investigation carried out on geogrids model to study the behavior of geogrid in the loose sandy soil. The effect of location eccentricity, depth of first layer of reinforcement, vertical spacing, number and type of reinforcement layers have been investigated. The results indicated that the percentage of bearing improvement a bout (22 %) at number of reinforced layers N=1 and about (47.5%) at number of reinforced layers N=2 for different Eccentricity values when depth ratio and vertical spacing between layers are (0.5B and 0.75B) respectively