There are two ways that the contract might be formed with (contracting between persons who are attended and contracting between absence persons).the need for determining the precise moment of the contract , is so clear because there is a specify period separate between the declaration of acceptance and the knowledge with it .and it is clear from the four theories known for jurisprudence (theory of the declaration of the acceptance, theory of exporting the acceptance , theory of the arrival of the acceptance , theory of the knowledge with the acceptance ) . It is difficult to promote one theory on another one if we look at each one and the justification of its supporters and what the opponents of each theory expose. Legal background and different circumstances for each country might have influence in determining the theory that must be adopted to determine the moment of contracting, while the preponderant opinion which represents a base that the supporter of each theory dashing from is the part that worth the protection, so if we want to considerate interest of the offer we will depend then on the acceptance theory or it leas the reach of the acceptance theory. While if we want to take the interest of the acceptor in consideration then we will follow the theory of the declaration of the acceptance or theory of sending the acceptance. United nation convention on contracts for the international sale of good has adopted theory of the arrival of the acceptance. While English law and Iraqi law have adopted theory of knowledge with the acceptance, while the theory of the declaration of the acceptance has been adopted by the Jordanian law.
A 5-traverse 2D resistivity survey and 20 Vertical Electrical Sounding (VES) points were carried out on Ile Epo Dump Site with a view to inferring the extent of migration of leachate plumes in the subsurface for possible contamination of groundwater. The surveys were carried out with Omega model resistivity meter. The Schlumberger configuration was employed for the VES while Wenner configuration was employed for the 2D resistivity survey (Constant Separation Techniques). The obtained VES and CST data were interpreted using WinResist and DIPRO respectively. The integrated results revealed three to four geo-electrically polluted materials as highly saturated fills (15 Ωm, 1.9 – 27.4m), saturated fills (15 - 30 Ωm, 3.6 – 29.9m) and un
... Show MoreThis paper presents a method to organize memory chips when they are used to build memory systems that have word size wider than 8-bit. Most memory chips have 8-bit word size. When the memory system has to be built from several memory chips of various sizes, this method gives all possible organizations of these chips in the memory system. This paper also suggests a precise definition of the term “memory bank” that is usually used in memory systems. Finally, an illustrative design problem was taken to illustrate the presented method practically
Epithelial‐mesenchymal transition (
This study thoroughly investigates the potential of niobium oxide (Nb2O5) thin films as UV-A photodetectors. The films were precisely fabricated using dc reactive magnetron sputtering on Si(100) and quartz substrates, maintaining a consistent power output of 50W while varying substrate temperatures. The dominant presence of hexagonal crystal structure Nb2O5 in the films was confirmed. An increased particle diameter at 150°C substrate temperature and a reduced Nb content at higher substrate temperatures were revealed. A distinct band gap with high UV sensitivity at 350 nm was determined. Remarkably, films sputtered using 50W displayed the highest photosensitivity at 514.89%. These outstanding optoelectronic properties highlight Nb2O5 thin f
... Show More
In this paper, we introduce and study new types of soft open sets and soft closed
sets in soft bitopological spaces (X,~ ,~ ,E) 1 2 , namely, (1,2)*-maximal soft open
sets, (1,2)*-maximal soft (1,2)*-pre-open sets, semi (1,2)*-maximal soft (1,2)*-preopen
sets, (1,2)*-maximal soft closed sets, (1,2)*-maximal soft (1,2)*-pre-closed
sets, (1,2)*-minimal soft open sets, (1,2)*-minimal soft (1,2)*-pre-open sets, (1,2)*-
minimal soft closed sets, (1,2)*-minimal soft (1,2)*-pre-closed sets, and semi (1,2)*-
minimal soft (1,2)*-pre-closed sets. Also, properties and the relation among these
concepts have been studied.
Time-domain spectral matching commonly used to define seismic inputs to dynamic analysis in terms of acceleration time history compatible with a specific target response spectrum is used in this study to investigate the second-order geometric effect of P-delta on the seismic response of base-isolated high-rise buildings. A synthetic time series is generated by adjusting reference time series that consist of available readings from a past earthquake of the 1940 El Centro earthquake adopted as an initial time series. The superstructure of a 20-story base isolated building is represented by a 3-D finite element model using ETABS software. The results of the base isolated building show that base isolation technique significantly reduces inter-s
... Show MoreThe present study aimed to examine the concordance between FISH/CISH techniques for assessment of amplification of her2neu gene in Iraqi breast carcinoma patients. Seventy four (74) Iraqi breast cancer patients were involved at the study from the Histopathology Department at the Central Public Health Laboratory in Bagdad, Iraq. Amplification of HER2neu was detected in (33.8%) by fluorescence in situ hybridization and (13.51%) showed high amplification by chromogenic in situ hybridization and (32.43%) showed low amplification. The results of chromogenic in situ hybridization were significantly correlated with the results of two-color fluorescence in situ hybridization with the same tumors. In addition, the study involved the correlation betw
... Show MoreA new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg
... Show More