The main objective of this paper is to develop and validate flow injection method, a precise, accurate, simple, economic, low cost and specific turbidimetric method for the quantitative determination of mebeverine hydrochloride (MbH) in pharmaceutical preparations. A homemade NAG Dual & Solo (0-180º) analyser which contains two identical detections units (cell 1 and 2) was applied for turbidity measurements. The developed method was optimized for different chemical and physical parameters such as perception reagent concentrations, aqueous salts solutions, flow rate, the intensity of the sources light, sample volume, mixing coil and purge time. The correlation coefficients (r) of the developed method were 0.9980 and 0.9986 for cell 1 and 2 respectively and showed the linearity of response against concentration over the range of 1.0 to 6.5 and 0.7-6.5mmol/L for cell 1 & 2 respectively. The limit of detections (LOD) for cell 1 and cell 2 were 0.28 and 0.21 mmol/L respectively. The intra-day and inter-day precision for two serial estimations of 3.5 and 5.5 mmol/L of MBH exhibited a relative standard deviation of 0.46%, 0.28%, 0.23%, 0.26% and 0.39%, 0.79%, 0.14%, 0.05% for cell 1 & 2 respectively. The accuracy of the developed method has expressed a recovery percentage (Rec %) and error % which was between 99.22 to 101.13 and 99.39 to 101.17 for cell 1 and cell 2 respectively. The ICH guidelines were followed for method validation. The developed method was successfully applied for the determination of MbH in pure and pharmaceutical preparations and the method can be conveniently used for routine analysis in laboratory as a quality control method since the method permits quantitively determination of 60 samples/h.
The flow measurements have increased importance in the last decades due to the shortage of water resources resulting from climate changes that request high control of the available water needed for different uses. The classical technique of open channel flow measurement by the integrating-float method was needed for measuring flow in different locations when there were no available modern devices for different reasons, such as the cost of devices. So, the use of classical techniques was taken place to solve the problem. The present study examines the integrating float method and defines the parameters affecting the acceleration of floating spheres in flowing water that was analyzed using experimental measurements. The me
... Show MoreAbstract:
Since the railway transport sector is very important in many countries of the world, we have tried through this research to study the production function of this sector and to indicate the level of productivity under which it operates.
It was found through the estimation and analysis of the production function Kub - Duglas that the railway transport sector in Iraq suffers from a decline in the level of productivity, which was reflected in the deterioration of the level of services provided for the transport of passengers and goods. This led to the loss of the sector of importance in supporting the national economy and the reluctance of most passengers an
... Show MoreThe lethality of inorganic arsenic (As) and the threat it poses have made the development of efficient As detection systems a vital necessity. This research work demonstrates a sensing layer made of hydrous ferric oxide (Fe2H2O4) to detect As(III) and As(V) ions in a surface plasmon resonance system. The sensor conceptualizes on the strength of Fe2H2O4 to absorb As ions and the interaction of plasmon resonance towards the changes occurring on the sensing layer. Detection sensitivity values for As(III) and As(V) were 1.083 °·ppb−1 and 0.922 °·ppb
The pharmacokinetics and bioequivalence of a newly developed extended-released (ER) tablet containing 400 mg pentoxifylline as a test product was compared with the reference brand product Trental® 400 mg ER tablet produced by Sanofi-Aventis. Two separate studies were conducted simultaneously. The first study was conducted under fasting condition, whereas, the second study was conducted under fed condition; using the same batches of the test and reference products in both studies. In each study, both products were administered to 32 healthy male adult volunteers applying a single-dose, two-treatment, two-period, two-sequence, randomized crossover design with one-week washout period between dosing. Twenty two blood samples we
... Show MoreBackground: Parvovirus B19 is a human pathogenic virus associated with a wide range of clinical conditions. During pregnancy congenital infection with parvovirus B19 can be associated with poor outcome, including miscarriage, fetal anemia and non-immune hydrops.
Objective: The study aimed to determine the prevalenceof Parvovirus B19 DNA in pregnant women attending the Military hospital in Khartoum, demonstrating the association between the virus and poor pregnancy outcomes.
Subjects and methods: This study was a cross sectional study, testing pregnant Sudanese women whole blood samples (n= 97) for the presence of Parvovirus B1
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreBackground: Diabetic nephropathy (DN) is a significant contributor to end-stage renal failure in individuals with type 2 diabetes mellitus (T2DM). Diabetic nephropathy is characterized by tubular atrophy, glomerular dilation, glomerulosclerosis, interstitial fibrosis, and proteinuria, resulting in deterioration of kidney function. DN, primarily caused by hyperglycemia, accounts for millions of deaths globally and is the leading cause of end-stage renal disease. Matrix metalloproteinase 10 is an enzyme essential for the breakdown of extracellular matrix constituents. Fetuin-A forms soluble complexes with calcium and phosphate to prevent soft tissue mineralization Objectives: To determine the levels of Matrix Metalloproteinase 10 and
... Show MoreBackground: Anemia is a common finding in patients with renal failure disease and it is, primarily, due to reduced production of iron and erythropoietin. Therefore, the aim of current study was to evaluate the relationship between serum level of hepcidin 25, on the one hand, and levels of serum iron, total iron-binding capacity, serum erythropoietin and transferrin saturation% in Iraqi male patients undrgoning haemodialysis.. Methods: Serum from75 males in the end stage of hemodialysis, as group one, and 25 Iraqi healthy malecontrols, as group two, were recruited in this study. Results: Data from current study showed significant increase in hepcidin 25 and significant decrease in serum iron, total iron-binding capacity, transferrin saturati
... Show MoreBackground This study establishes a mathematically consistent and computational framework for the simultaneous identification of two time-dependent coefficients in a one-dimensional second-order parabolic partial differential equation. The considered problem is governed by nonlocal initial, boundary, and integral overdetermination conditions. Methods The direct problem is solved using the Crank-Nicolson finite difference method (FDM), which ensures unconditional stability and second-order accuracy in both spatial and temporal discretizations. The corresponding inverse problem is reformulated as a nonlinear regularized least-squares optimization problem and efficiently solved used the MATLAB subroutine
... Show More